Last modified by Iaroslav Platonov on 2026/06/08 10:08

From version 6.7
edited by Lana
on 2025/12/03 21:57
Change comment: There is no comment for this version
To version 6.2
edited by Lana
on 2025/12/03 21:51
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -74,308 +74,4 @@
74 74  
75 75  Table 1 – CENTO software components
76 76  
77 -|(% style="text-align:center" %)**№**|(% style="text-align:center; width:214px" %)**Service Name**|(% style="text-align:center; width:676px" %)**Function**|(% style="text-align:center; width:358px" %)**Metrologically significant part**
78 -|(% colspan="4" style="text-align:center" %)**Data collection and transmission services**
79 -|(((
80 -~1.
81 -)))|(% style="width:214px" %)sed_bus_dispatcher|(% style="width:676px" %)Sequential Device Polling Management Service|(% style="width:358px" %)
82 -|(((
83 -2.
84 -)))|(% style="width:214px" %)sed_xml_reader|(% style="width:676px" %)Service for processing received XML files 80020|(% style="width:358px" %)
85 -|(((
86 -3.
87 -)))|(% style="width:214px" %)sed_xml_send|(% style="width:676px" %)XML file transfer Service 80020|(% style="width:358px" %)
88 -|(((
89 -4.
90 -)))|(% style="width:214px" %)sed_archive_webapi|(% style="width:676px" %)Implementation of the web API for transmitting archived data according to the CENTO documentation|(% style="width:358px" %)
91 -|(((
92 -5.
93 -)))|(% style="width:214px" %)sed_s2s_configuration|(% style="width:676px" %)Configuration transmission service between CENTO servers|(% style="width:358px" %)
94 -|(% colspan="4" style="text-align:center" %)**Data collection and transmission services using standard protocols**
95 -|6.|(% style="width:214px" %)sed_modbus_rtd|(% style="width:676px" %)A service for reading real-time data from devices using Modbus protocol (Modbus TCP and Modbus RTU over TCP)|(% style="width:358px" %)sed_metrology_001.bin
96 -|7.|(% style="width:214px" %)sed_modbus_rtd_send|(% style="width:676px" %)A service for sending real-time data to third-party devices using the Modbus TCP protocol|(% style="width:358px" %)
97 -|8.|(% style="width:214px" %)sed_modbus_sync|(% style="width:676px" %)A device time synchronization service using Modbus protocol (Modbus TCP and Modbus RTU over TCP)|(% style="width:358px" %)
98 -|9.|(% style="width:214px" %)sed_snmp_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the SNMP (v1, v2c, v3), ICMP protocols|(% style="width:358px" %)
99 -|10.|(% style="width:214px" %)sed_iec103_waveform|(% style="width:676px" %)A service for reading waveform files from devices using the IEC protocol-60870-5-103|(% style="width:358px" %)sed_metrology_393.bin
100 -|11.|(% style="width:214px" %)sed_iec104_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the IEC 60870-5-104 protocol|(% style="width:358px" %)sed_metrology_011.bin
101 -|12.|(% style="width:214px" %)sed_iec104_rtd_send|(% style="width:676px" %)A service for sending real-time data to third-party devices using the IEC 60870-5-104 protocol|(% style="width:358px" %)sed_metrology_012.bin
102 -|13.|(% style="width:214px" %)sed_opcda_rtd|(% style="width:676px" %)A service for receiving real-time data using the OPC DA protocol|(% style="width:358px" %)
103 -|14.|(% style="width:214px" %)sed_opcua_rtd|(% style="width:676px" %)A service for receiving real-time data using the OPC UA protocol|(% style="width:358px" %)
104 -|15.|(% style="width:214px" %)sed_opcua_arch|(% style="width:676px" %)A service for receiving archived data using the OPC UA protocol|(% style="width:358px" %)sed_metrology_402.bin
105 -|16.|(% style="width:214px" %)sed_opcua_server|(% style="width:676px" %)A service for transmitting data using the OPC UA protocol|(% style="width:358px" %)
106 -|17.|(% style="width:214px" %)sed_dnp3_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the DNP3 protocol|(% style="width:358px" %)
107 -|18.|(% style="width:214px" %)sed_ftp_waveform|(% style="width:676px" %)A service for receiving waveform files via FTP protocol|(% style="width:358px" %)sed_metrology_380.bin
108 -|19.|(% style="width:214px" %)sed_iec61107_rtd|(% style="width:676px" %)A service for obtaining real-time data from devices using the IEC 62056-21 protocol|(% style="width:358px" %)sed_metrology_61107.bin
109 -|20.|(% style="width:214px" %)sed_iec61850_arch|(% style="width:676px" %)A service for receiving archived data from devices using the IEC 61850 protocol|(% style="width:358px" %)
110 -|21.|(% style="width:214px" %)sed_iec61850_rtd|(% style="width:676px" %)A service for receiving operational data from devices using the IEC 61850 protocol|(% style="width:358px" %)
111 -|(% colspan="4" style="text-align:center" %)**Proprietary protocol data collection and transmission services**
112 -|22.|(% style="width:214px" %)sed_satec_arch|(% style="width:676px" %)A service for reading archived data (metering and event logs) from SATEC devices|(% style="width:358px" %)sed_metrology_7_8.bin
113 -|23.|(% style="width:214px" %)sed_satec_pq_journal|(% style="width:676px" %)A service for obtaining event logs for monitoring the power quality from Satec devices|(% style="width:358px" %)sed_metrology_106.bin
114 -|24.|(% style="width:214px" %)sed_satec_pq_report|(% style="width:676px" %)A service for receiving reports on the power quality control from Satec devices|(% style="width:358px" %)sed_metrology_106.bin
115 -|25.|(% style="width:214px" %)sed_satec_waveforms|(% style="width:676px" %)A service for proofreading waveforms from SATEC devices using Modbus TCP and RTU over TCP protocols|(% style="width:358px" %)sed_metrology_108_109.bin
116 -|26.|(% style="width:214px" %)sed_iec103_rtd|(% style="width:676px" %)A service for reading real-time data from TOR 200 terminals according to the IEC protocol-60870-5-103|(% style="width:358px" %)sed_metrology_391.bin
117 -|27.|(% style="width:214px" %)sed_sepam_waveform|(% style="width:676px" %)A service for proofreading waveforms and time synchronization using the Modbus RTU over TCP protocol from Sepam devices|(% style="width:358px" %)sed_metrology_298_299.bin
118 -|28.|(% style="width:214px" %)sed_rtu_over_tcp_logikamp_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the LogicaMP RTU over TCP protocol|(% style="width:358px" %)sed_metrology_121.bin
119 -|29.|(% style="width:214px" %)sed_rtu_over_tcp_logikamp_arch|(% style="width:676px" %)A service for reading archived data from devices using the LogicaMP RTU over TCP protocol|(% style="width:358px" %)sed_metrology_122.bin
120 -|30.|(% style="width:214px" %)sed_axis_video_journal|(% style="width:676px" %)An AXIS camera recording service|(% style="width:358px" %)sed_metrology_435.bin
121 -|31.|(% style="width:214px" %)sed_vzlyotmb_arch|(% style="width:676px" %)A service for reading archives and event logs of devices Vzlet TSRV-043, TSRV-027, IVK-TER|(% style="width:358px" %)sed_metrology_25_133.bin
122 -|32.|(% style="width:214px" %)sed_micom_waveforms|(% style="width:676px" %)A service for reading waveform files from Micom devices using Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_370.bin
123 -|33.|(% style="width:214px" %)sed_pulsar_arch|(% style="width:676px" %)A service for reading archives from Pulsar devices using the Modbus protocol|(% style="width:358px" %)sed_metrology_342.bin
124 -|34.|(% style="width:214px" %)sed_rtu_over_tcp_a1800_arch|(% style="width:676px" %)A service for receiving archived data from A1800 meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_232.bin
125 -|35.|(% style="width:214px" %)sed_rtu_over_tcp_a1800_rtd|(% style="width:676px" %)A service for receiving real-time data from A1800 meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_231.bin
126 -|36.|(% style="width:214px" %)sed_rtu_over_tcp_acron_arch|(% style="width:676px" %)A service for receiving archived data from Acron meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_142.bin
127 -|37.|(% style="width:214px" %)sed_rtu_over_tcp_acron_rtd|(% style="width:676px" %)A service for receiving real-time data from Acron meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_141.bin
128 -|38.|(% style="width:214px" %)sed_rtu_over_tcp_bmrz_waveform|(% style="width:676px" %)A service for reading waveform files from BMRZ terminals using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_110.bin
129 -|39.|(% style="width:214px" %)sed_rtu_over_tcp_bzp03_waveform|(% style="width:676px" %)A service for reading waveform files from BZP-03 terminals using Modbus RTU over TCP protocol|(% style="width:358px" %)
130 -|40.|(% style="width:214px" %)sed_rtu_over_tcp_kmp_rtd|(% style="width:676px" %)A service for polling Multitical 601 device using the KMP protocol|(% style="width:358px" %)sed_metrology_191.bin
131 -|41.|(% style="width:214px" %)sed_rtu_over_tcp_majac_arch|(% style="width:676px" %)A service for receiving archived data from devices using the Mayak protocol|(% style="width:358px" %)sed_metrology_152.bin
132 -|42.|(% style="width:214px" %)sed_rtu_over_tcp_mercury200_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the Mercury 200 protocol|(% style="width:358px" %)sed_metrology_251.bin
133 -|43.|(% style="width:214px" %)sed_rtu_over_tcp_mercury_arch|(% style="width:676px" %)A service for reading archives and event logs from Mercury-230 series devices using the Mercury-230 protocol|(% style="width:358px" %)sed_metrology_202.bin
134 -|44.|(% style="width:214px" %)sed_rtu_over_tcp_mercury_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the Mercury 230 protocol|(% style="width:358px" %)sed_metrology_201.bin
135 -|45.|(% style="width:214px" %)sed_rtu_over_tcp_photon_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the photon RTU over TCP protocol|(% style="width:358px" %)sed_metrology_221.bin
136 -|46.|(% style="width:214px" %)sed_rtu_over_tcp_ref542plus_waveform|(% style="width:676px" %)Proofreading of waveforms and time synchronization via Modbus RTU over TCP protocol from ABB REF 542plus devices|(% style="width:358px" %)
137 -|47.|(% style="width:214px" %)sed_rtu_over_tcp_set4tm_arch|(% style="width:676px" %)A service for polling SET-4TM, PSC meters’ archives|(% style="width:358px" %)sed_metrology_112.bin
138 -|48.|(% style="width:214px" %)sed_rtu_over_tcp_set4tm_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the SET-4TM rtu over tcp protocol|(% style="width:358px" %)sed_metrology_111.bin
139 -|49.|(% style="width:214px" %)sed_rtu_over_tcp_tem104_arch|(% style="width:676px" %)A service for receiving archived data from devices using the TEM104 protocol|(% style="width:358px" %)sed_metrology_162.bin
140 -|50.|(% style="width:214px" %)sed_rtu_over_tcp_tem104_rtd|(% style="width:676px" %)A service for receiving real-tume data from devices using the TEM104 protocol|(% style="width:358px" %)sed_metrology_161.bin
141 -|51.|(% style="width:214px" %)sed_rtu_over_tcp_vist_arch|(% style="width:676px" %)A service for receiving archived data from devices using the VIS.T protocol|(% style="width:358px" %)sed_metrology_172.bin
142 -|52.|(% style="width:214px" %)sed_rtu_over_tcp_vkt5_arch|(% style="width:676px" %)A service for receiving archived data from VKT-5 devices|(% style="width:358px" %)sed_metrology_312.bin
143 -| |(% style="width:214px" %)sed_rtu_over_tcp_vkt5_rtd|(% style="width:676px" %)A service for receiving real-time data from VKT-5 devices|(% style="width:358px" %)sed_metrology_311.bin
144 -| |(% style="width:214px" %)sed_vkt7_arch|(% style="width:676px" %)A service for receiving archived data from VKT-7 devices|(% style="width:358px" %)
145 -| |(% style="width:214px" %)sed_vkt7_rtd|(% style="width:676px" %)A service for receiving real-time data from VKT-7 devices|(% style="width:358px" %)
146 -| |(% style="width:214px" %)sed_rtu_over_tcp_vtd_arch|(% style="width:676px" %)A service for receiving archived data of VTD devices|(% style="width:358px" %)sed_metrology_182.bin
147 -| |(% style="width:214px" %)sed_rtu_over_tcp_vtd_rtd|(% style="width:676px" %)A service for receiving operational data from VTD devices|(% style="width:358px" %)sed_metrology_181.bin
148 -| |(% style="width:214px" %)sed_uvp_arch|(% style="width:676px" %)A service for poling Promavtomatika's archive for devices of the UVP series|(% style="width:358px" %)sed_metrology_352.bin
149 -| |(% style="width:214px" %)sed_ce_arch|(% style="width:676px" %)A service for receiving archived data from Energomera devices of the CE series according to the IEC61107 protocol|(% style="width:358px" %)sed_metrology_362.bin
150 -| |(% style="width:214px" %)sed_alpha_arch|(% style="width:676px" %)A service for receiving archived data from Alfa-3 devices manufactured by Alfamera|(% style="width:358px" %)sed_metrology_462_472.bin
151 -| |(% style="width:214px" %)sed_bug01_rtd|(% style="width:676px" %)A service for receiving archived data of BUG-01 devices|(% style="width:358px" %)sed_metrology_491.bin
152 -| |(% style="width:214px" %)sed_dymetic_arch|(% style="width:676px" %)A service for receiving archived data from Dimetik|(% style="width:358px" %)sed_metrology_552.bin
153 -| |(% style="width:214px" %)sed_irvis_arch|(% style="width:676px" %)A service for receiving archived data from devices using the Irvis protocol|(% style="width:358px" %)sed_metrology_442.bin
154 -| |(% style="width:214px" %)sed_karat_arch|(% style="width:676px" %)A service for receiving archived data from Karat devices|(% style="width:358px" %)sed_metrology_512.bin
155 -| |(% style="width:214px" %)sed_lis200_arch|(% style="width:676px" %)A service for receiving archived data from the EK-260 and EK-270 devices manufactured by Elster|(% style="width:358px" %)sed_metrology_452.bin
156 -| |(% style="width:214px" %)sed_rtu_over_tcp_sepam_waveform|(% style="width:676px" %)A service for reading waveform files from Sepam devices using Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_298.bin
157 -|(% colspan="4" style="text-align:center" %)**Data export and import services in SQL databases**
158 -| |(% style="width:214px" %)sed_sql_rtd|(% style="width:676px" %)A service for receiving tele-measurement data from MySQL|(% style="width:358px" %)sed_metrology_211.bin
159 -| |(% style="width:214px" %)sed_sql_arch|(% style="width:676px" %)A service for archived data retrieval from Microsoft SQL Server|(% style="width:358px" %)
160 -| |(% style="width:214px" %)sed_sql_arch_send|(% style="width:676px" %)A service for recording archived data in an external SQL database|(% style="width:358px" %)
161 -|(% colspan="4" style="text-align:center" %)**Data processing services**
162 -|(((
163 -1.
164 -)))|(% style="width:214px" %)sed_controller|(% style="width:676px" %)A service for telemetry reception and processing (writes to the InfluxDB database)|(% style="width:358px" %)sed_metrology_controller.bin
165 -|(((
166 -1.
167 -)))|(% style="width:214px" %)sed_events_calc|(% style="width:676px" %)A service for generating event based on the conditions specified in the configuration|(% style="width:358px" %)
168 -|(((
169 -1.
170 -)))|(% style="width:214px" %)sed_calc_arch|(% style="width:676px" %)A service for calculating metering channels|(% style="width:358px" %)(((
171 -sed_metrology_calc_arch.bin
172 -
173 -sed_metrology_formulas.bin
174 -)))
175 -|(((
176 -1.
177 -)))|(% style="width:214px" %)sed_calc_rtd|(% style="width:676px" %)A service for calculating pre-calculated tags|(% style="width:358px" %)
178 -|(((
179 -1.
180 -)))|(% style="width:214px" %)sed_round_arch|(% style="width:676px" %)A service for calculating metering channels with rounding|(% style="width:358px" %)sed_metrology_round_arch.bin
181 -|(((
182 -1.
183 -)))|(% style="width:214px" %)sed_energy_calc|(% style="width:676px" %)A service for server-level energy resource calculation|(% style="width:358px" %)sed_metrology_411_421.bin
184 -|(((
185 -1.
186 -)))|(% style="width:214px" %)sed_loadflow_calc|(% style="width:676px" %)A service for calculating modes based on an information model|(% style="width:358px" %)
187 -|(((
188 -1.
189 -)))|(% style="width:214px" %)sed_storage_writer|(% style="width:676px" %)A service for recording archived data (metering and event logs) in a data storage (InfluxDB and MongoDB)|(% style="width:358px" %)
190 -|(% colspan="4" %)**Web Part Services**
191 -|(((
192 -1.
193 -)))|(% style="width:214px" %)php5-cgi|(% style="width:676px" %)A Web Query Service|(% style="width:358px" %)
194 -|(((
195 -1.
196 -)))|(% style="width:214px" %)nginx|(% style="width:676px" %)A Web Server|(% style="width:358px" %)
197 -|(((
198 -1.
199 -)))|(% style="width:214px" %)sed_ui|(% style="width:676px" %)A service for processing requests for web resources (js, css, html files)|(% style="width:358px" %)
200 -|(((
201 -1.
202 -)))|(% style="width:214px" %)sed_rtd_analysis|(% style="width:676px" %)A service for analyzing real-time data|(% style="width:358px" %)
203 -|(((
204 -1.
205 -)))|(% style="width:214px" %)sed_auth|(% style="width:676px" %)A service for authenticating and authorizing users in the system and configuring access rights|(% style="width:358px" %)
206 -|(((
207 -1.
208 -)))|(% style="width:214px" %)sed_auth_privileges|(% style="width:676px" %)A User Privilege Management Service|(% style="width:358px" %)
209 -|(((
210 -1.
211 -)))|(% style="width:214px" %)sed_api_gateway|(% style="width:676px" %)A service for proxying of web requests to other services within the system|(% style="width:358px" %)
212 -|(((
213 -1.
214 -)))|(% style="width:214px" %)sed_dataset_configurator|(% style="width:676px" %)A service for working with datasets|(% style="width:358px" %)
215 -|(((
216 -1.
217 -)))|(% style="width:214px" %)sed_rtd|(% style="width:676px" %)A real-time data subscription service|(% style="width:358px" %)
218 -|(((
219 -1.
220 -)))|(% style="width:214px" %)sed_rtd_archive|(% style="width:676px" %)A service for generating archived data from real-time data|(% style="width:358px" %)
221 -|(((
222 -1.
223 -)))|(% style="width:214px" %)sed_system|(% style="width:676px" %)A service that provides a user interface with information about the system|(% style="width:358px" %)
224 -|(((
225 -1.
226 -)))|(% style="width:214px" %)sed_archive|(% style="width:676px" %)A service that provides user interfaces for analyzing electricity and energy accounting|(% style="width:358px" %)
227 -|(((
228 -1.
229 -)))|(% style="width:214px" %)sed_archive_integrity|(% style="width:676px" %)A service that provides user interfaces for analyzing the completeness of electricity and energy resources data|(% style="width:358px" %)
230 -|(((
231 -1.
232 -)))|(% style="width:214px" %)sed_pq_reports|(% style="width:676px" %)A service for working with power quality reports|(% style="width:358px" %)
233 -|(((
234 -1.
235 -)))|(% style="width:214px" %)sed_pq_journal|(% style="width:676px" %)A service for working with power quality logs|(% style="width:358px" %)
236 -|(((
237 -1.
238 -)))|(% style="width:214px" %)sed_ras_configurator|(% style="width:676px" %)A service for configuring emergency event loggers|(% style="width:358px" %)
239 -|(((
240 -1.
241 -)))|(% style="width:214px" %)sed_reports|(% style="width:676px" %)A service for generating and managing reports, and maintaining user interfaces for reports|(% style="width:358px" %)
242 -|(((
243 -1.
244 -)))|(% style="width:214px" %)sed_widgets|(% style="width:676px" %)A service for the user interfaces of drag'n'drop widgets|(% style="width:358px" %)
245 -|(((
246 -1.
247 -)))|(% style="width:214px" %)sed_menu|(% style="width:676px" %)A service for displaying and configuring CENTO system menu|(% style="width:358px" %)
248 -|(((
249 -1.
250 -)))|(% style="width:214px" %)sed_mnemonic_diagrams|(% style="width:676px" %)A service for the user interfaces of diagrams v2|(% style="width:358px" %)
251 -|(((
252 -1.
253 -)))|(% style="width:214px" %)sed_configuration|(% style="width:676px" %)A service for user interfaces for system configuration (alerts, mail servers, formulas, device trees)|(% style="width:358px" %)
254 -|(((
255 -1.
256 -)))|(% style="width:214px" %)sed_devices_configurator|(% style="width:676px" %)A service for editing device configurations, tags, and channels|(% style="width:358px" %)
257 -|(((
258 -1.
259 -)))|(% style="width:214px" %)sed_common_event_journal|(% style="width:676px" %)A service for user interfaces for generalized configurable event logs|(% style="width:358px" %)
260 -|(((
261 -1.
262 -)))|(% style="width:214px" %)sed_device_event_journal|(% style="width:676px" %)A Device Log Service|(% style="width:358px" %)
263 -|(((
264 -1.
265 -)))|(% style="width:214px" %)sed_operative_journal|(% style="width:676px" %)A service for the user interface of the real-time event log|(% style="width:358px" %)
266 -|(((
267 -1.
268 -)))|(% style="width:214px" %)sed_video_journal|(% style="width:676px" %)A Video Camera Log Service|(% style="width:358px" %)
269 -|(((
270 -1.
271 -)))|(% style="width:214px" %)sed_marking|(% style="width:676px" %)A Dispatch Tag Management Service|(% style="width:358px" %)
272 -|(((
273 -1.
274 -)))|(% style="width:214px" %)sed_sounds|(% style="width:676px" %)A service for the user interface for sound alerts management|(% style="width:358px" %)
275 -|(((
276 -1.
277 -)))|(% style="width:214px" %)sed_video_stream|(% style="width:676px" %)A service for streaming video from cameras registered in the information model|(% style="width:358px" %)
278 -|(% colspan="4" %)**System services**
279 -|(((
280 -1.
281 -)))|(% style="width:214px" %)nats|(% style="width:676px" %)A message broker and a service registry (service registry/service discovery)|(% style="width:358px" %)
282 -|(((
283 -1.
284 -)))|(% style="width:214px" %)influxdb|(% style="width:676px" %)A time series database|(% style="width:358px" %)
285 -|(((
286 -1.
287 -)))|(% style="width:214px" %)mongod|(% style="width:676px" %)A database of configuration and structured data (event logs, requests)|(% style="width:358px" %)
288 -|(((
289 -1.
290 -)))|(% style="width:214px" %)sed_signals|(% style="width:676px" %)A signal reception and transmission service inside the system (remote control, configuration update, manual polling, parameter recalculation)|(% style="width:358px" %)
291 -|(((
292 -1.
293 -)))|(% style="width:214px" %)sed_debug|(% style="width:676px" %)A service for providing access to debugging information of CENTO services|(% style="width:358px" %)
294 -|(((
295 -1.
296 -)))|(% style="width:214px" %)sed_graphql|(% style="width:676px" %)A subscription service for device statuses|(% style="width:358px" %)
297 -|(((
298 -1.
299 -)))|(% style="width:214px" %)sed_energy_calc_configuration|(% style="width:676px" %)A service for creating, changing, and deleting energy resource calculation configurations at the server level|(% style="width:358px" %)
300 -|(((
301 -1.
302 -)))|(% style="width:214px" %)sed_backup|(% style="width:676px" %)A service for backing up data according to the cron rule.|(% style="width:358px" %)
303 -|(((
304 -1.
305 -)))|(% style="width:214px" %)sed_channels|(% style="width:676px" %)A channel subscription service|(% style="width:358px" %)
306 -|(((
307 -1.
308 -)))|(% style="width:214px" %)sed_channels_data|(% style="width:676px" %)A subscription service for protocol statuses and the latest channel data|(% style="width:358px" %)
309 -|(((
310 -1.
311 -)))|(% style="width:214px" %)sed_emission_archive|(% style="width:676px" %)A service for providing emissions metering data|(% style="width:358px" %)
312 -|(((
313 -1.
314 -)))|(% style="width:214px" %)sed_profile_archive|(% style="width:676px" %)A service for providing metering data from InfluxDB via gRPC.|(% style="width:358px" %)
315 -|(((
316 -1.
317 -)))|(% style="width:214px" %)sed_web_storage|(% style="width:676px" %)A service for accessing archived metering data|(% style="width:358px" %)
318 -|(((
319 -1.
320 -)))|(% style="width:214px" %)sed_watchdog|(% style="width:676px" %)A service for managing the launch of CENTO services|(% style="width:358px" %)
321 -|(((
322 -1.
323 -)))|(% style="width:214px" %)sed_scheduler|(% style="width:676px" %)A service for launching scheduled tasks|(% style="width:358px" %)
324 -|(((
325 -1.
326 -)))|(% style="width:214px" %)sed_license|(% style="width:676px" %)A licensing service|(% style="width:358px" %)
327 -|(((
328 -1.
329 -)))|(% style="width:214px" %)sed_monitor|(% style="width:676px" %)A service for monitoring the operation of the system's services and applications|(% style="width:358px" %)
330 -|(((
331 -1.
332 -)))|(% style="width:214px" %)sed_telecontrol|(% style="width:676px" %)A remote control service|(% style="width:358px" %)
333 -|(((
334 -1.
335 -)))|(% style="width:214px" %)sed_notificator|(% style="width:676px" %)A service for notifying users about events by e-mail|(% style="width:358px" %)
336 -|(((
337 -1.
338 -)))|(% style="width:214px" %)sed_waveforms_journal|(% style="width:676px" %)A waveform Log Service|(% style="width:358px" %)
339 -|(((
340 -1.
341 -)))|(% style="width:214px" %)sed_storage_configurator|(% style="width:676px" %)An InfluxDB Database Configuration Service|(% style="width:358px" %)
342 -|(((
343 -1.
344 -)))|(% style="width:214px" %)sed_system_configuration|(% style="width:676px" %)A CENTO System Configuration Editing Service|(% style="width:358px" %)
345 -|(((
346 -1.
347 -)))|(% style="width:214px" %)sed_user_settings|(% style="width:676px" %)A User Settings Configuration Service|(% style="width:358px" %)
348 -|(((
349 -1.
350 -)))|(% style="width:214px" %)sed_system_event_journal|(% style="width:676px" %)A service for registration and provision of system events (business logic and administration)|(% style="width:358px" %)
351 -|(((
352 -1.
353 -)))|(% style="width:214px" %)sed_tech_event_journal|(% style="width:676px" %)A service for processing and managing technological events|(% style="width:358px" %)
354 -|(((
355 -1.
356 -)))|(% style="width:214px" %)sed_information_model|(% style="width:676px" %)A System Information Model Management Service|(% style="width:358px" %)
357 -|(((
358 -1.
359 -)))|(% style="width:214px" %)sed_events_configurator|(% style="width:676px" %)A System Event Configuration Service|(% style="width:358px" %)
360 -|(((
361 -1.
362 -)))|(% style="width:214px" %)sed_information_model_editor|(% style="width:676px" %)A service for editing the information model|(% style="width:358px" %)
363 -|(% colspan="4" %)**Server Backup Services**
364 -|(((
365 -1.
366 -)))|(% style="width:214px" %)sed_coordinator|(% style="width:676px" %)A service for selecting the cluster's host server using the Bully leader election algorithm|(% style="width:358px" %)
367 -|(((
368 -1.
369 -)))|(% style="width:214px" %)sed_reserve|(% style="width:676px" %)A service for displaying a list of backup servers|(% style="width:358px" %)
370 -|(((
371 -1.
372 -)))|(% style="width:214px" %)sed_replicator|(% style="width:676px" %)A log replication service between cluster servers|(% style="width:358px" %)
373 -|(((
374 -1.
375 -)))|(% style="width:214px" %)sed_influx_replicator|(% style="width:676px" %)A data replication service (archives and telemetry) between cluster servers|(% style="width:358px" %)
376 -|(((
377 -1.
378 -)))|(% style="width:214px" %)sed_events_replicator|(% style="width:676px" %)An event replication service between cluster servers|(% style="width:358px" %)
379 -|(((
380 -1.
381 -)))|(% style="width:214px" %)sed_fs_synch|(% style="width:676px" %)A data replication service (gob files, reports, waveforms) between cluster servers|(% style="width:358px" %)
77 +