Changes for page 4. Structure and Modules Description
Last modified by Iaroslav Platonov on 2026/06/08 10:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -74,100 +74,230 @@ 74 74 75 75 Table 1 – CENTO software components 76 76 77 -| (% style="text-align:center" %)**№**|(% style="text-align:center; width:214px" %)**Service Name**|(% style="text-align:center; width:676px" %)**Function**|(% style="text-align:center; width:358px" %)**Metrologically significant part**78 -|(% colspan="4" style="text-align:center"%)**Data collection and transmission services**77 +|№|Service Name|Function|Metrologically significant part 78 +|(% colspan="4" %)**Data collection and transmission services** 79 79 |((( 80 80 ~1. 81 -)))| (%style="width:214px" %)sed_bus_dispatcher|(% style="width:676px" %)Sequential Device Polling Management Service|(%style="width:358px" %)81 +)))|sed_bus_dispatcher|Sequential Device Polling Management Service| 82 82 |((( 83 83 2. 84 -)))| (%style="width:214px" %)sed_xml_reader|(% style="width:676px" %)Service for processing received XML files 80020|(%style="width:358px" %)84 +)))|sed_xml_reader|Service for processing received XML files 80020| 85 85 |((( 86 86 3. 87 -)))| (%style="width:214px" %)sed_xml_send|(% style="width:676px" %)XML file transfer Service 80020|(%style="width:358px" %)87 +)))|sed_xml_send|XML file transfer Service 80020| 88 88 |((( 89 -4. 90 -)))|(% style="width:214px" %)sed_archive_webapi|(% style="width:676px" %)Implementation of the web API for transmitting archived data according to the CENTO documentation|(% style="width:358px" %) 89 + 90 + 91 +1. 92 +)))|sed_archive_webapi|Implementation of the web API for transmitting archived data according to the CENTO documentation| 91 91 |((( 92 -5. 93 -)))|(% style="width:214px" %)sed_s2s_configuration|(% style="width:676px" %)Configuration transmission service between CENTO servers|(% style="width:358px" %) 94 -|(% colspan="4" style="text-align:center" %)**Data collection and transmission services using standard protocols** 95 -|6.|(% style="width:214px" %)sed_modbus_rtd|(% style="width:676px" %)A service for reading real-time data from devices using Modbus protocol (Modbus TCP and Modbus RTU over TCP)|(% style="width:358px" %)sed_metrology_001.bin 96 -|7.|(% style="width:214px" %)sed_modbus_rtd_send|(% style="width:676px" %)A service for sending real-time data to third-party devices using the Modbus TCP protocol|(% style="width:358px" %) 97 -|8.|(% style="width:214px" %)sed_modbus_sync|(% style="width:676px" %)A device time synchronization service using Modbus protocol (Modbus TCP and Modbus RTU over TCP)|(% style="width:358px" %) 98 -|9.|(% style="width:214px" %)sed_snmp_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the SNMP (v1, v2c, v3), ICMP protocols|(% style="width:358px" %) 99 -|10.|(% style="width:214px" %)sed_iec103_waveform|(% style="width:676px" %)A service for reading waveform files from devices using the IEC protocol-60870-5-103|(% style="width:358px" %)sed_metrology_393.bin 100 -|11.|(% style="width:214px" %)sed_iec104_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the IEC 60870-5-104 protocol|(% style="width:358px" %)sed_metrology_011.bin 101 -|12.|(% style="width:214px" %)sed_iec104_rtd_send|(% style="width:676px" %)A service for sending real-time data to third-party devices using the IEC 60870-5-104 protocol|(% style="width:358px" %)sed_metrology_012.bin 102 -|13.|(% style="width:214px" %)sed_opcda_rtd|(% style="width:676px" %)A service for receiving real-time data using the OPC DA protocol|(% style="width:358px" %) 103 -|14.|(% style="width:214px" %)sed_opcua_rtd|(% style="width:676px" %)A service for receiving real-time data using the OPC UA protocol|(% style="width:358px" %) 104 -|15.|(% style="width:214px" %)sed_opcua_arch|(% style="width:676px" %)A service for receiving archived data using the OPC UA protocol|(% style="width:358px" %)sed_metrology_402.bin 105 -|16.|(% style="width:214px" %)sed_opcua_server|(% style="width:676px" %)A service for transmitting data using the OPC UA protocol|(% style="width:358px" %) 106 -|17.|(% style="width:214px" %)sed_dnp3_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the DNP3 protocol|(% style="width:358px" %) 107 -|18.|(% style="width:214px" %)sed_ftp_waveform|(% style="width:676px" %)A service for receiving waveform files via FTP protocol|(% style="width:358px" %)sed_metrology_380.bin 108 -|19.|(% style="width:214px" %)sed_iec61107_rtd|(% style="width:676px" %)A service for obtaining real-time data from devices using the IEC 62056-21 protocol|(% style="width:358px" %)sed_metrology_61107.bin 109 -|20.|(% style="width:214px" %)sed_iec61850_arch|(% style="width:676px" %)A service for receiving archived data from devices using the IEC 61850 protocol|(% style="width:358px" %) 110 -|21.|(% style="width:214px" %)sed_iec61850_rtd|(% style="width:676px" %)A service for receiving operational data from devices using the IEC 61850 protocol|(% style="width:358px" %) 111 -|(% colspan="4" style="text-align:center" %)**Proprietary protocol data collection and transmission services** 112 -|22.|(% style="width:214px" %)sed_satec_arch|(% style="width:676px" %)A service for reading archived data (metering and event logs) from SATEC devices|(% style="width:358px" %)sed_metrology_7_8.bin 113 -|23.|(% style="width:214px" %)sed_satec_pq_journal|(% style="width:676px" %)A service for obtaining event logs for monitoring the power quality from Satec devices|(% style="width:358px" %)sed_metrology_106.bin 114 -|24.|(% style="width:214px" %)sed_satec_pq_report|(% style="width:676px" %)A service for receiving reports on the power quality control from Satec devices|(% style="width:358px" %)sed_metrology_106.bin 115 -|25.|(% style="width:214px" %)sed_satec_waveforms|(% style="width:676px" %)A service for proofreading waveforms from SATEC devices using Modbus TCP and RTU over TCP protocols|(% style="width:358px" %)sed_metrology_108_109.bin 116 -|26.|(% style="width:214px" %)sed_iec103_rtd|(% style="width:676px" %)A service for reading real-time data from TOR 200 terminals according to the IEC protocol-60870-5-103|(% style="width:358px" %)sed_metrology_391.bin 117 -| |(% style="width:214px" %)sed_sepam_waveform|(% style="width:676px" %)A service for proofreading waveforms and time synchronization using the Modbus RTU over TCP protocol from Sepam devices|(% style="width:358px" %)sed_metrology_298_299.bin 118 -| |(% style="width:214px" %)sed_rtu_over_tcp_logikamp_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the LogicaMP RTU over TCP protocol|(% style="width:358px" %)sed_metrology_121.bin 119 -| |(% style="width:214px" %)sed_rtu_over_tcp_logikamp_arch|(% style="width:676px" %)A service for reading archived data from devices using the LogicaMP RTU over TCP protocol|(% style="width:358px" %)sed_metrology_122.bin 120 -| |(% style="width:214px" %)sed_axis_video_journal|(% style="width:676px" %)An AXIS camera recording service|(% style="width:358px" %)sed_metrology_435.bin 121 -| |(% style="width:214px" %)sed_vzlyotmb_arch|(% style="width:676px" %)A service for reading archives and event logs of devices Vzlet TSRV-043, TSRV-027, IVK-TER|(% style="width:358px" %)sed_metrology_25_133.bin 122 -| |(% style="width:214px" %)sed_micom_waveforms|(% style="width:676px" %)A service for reading waveform files from Micom devices using Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_370.bin 123 -| |(% style="width:214px" %)sed_pulsar_arch|(% style="width:676px" %)A service for reading archives from Pulsar devices using the Modbus protocol|(% style="width:358px" %)sed_metrology_342.bin 124 -| |(% style="width:214px" %)sed_rtu_over_tcp_a1800_arch|(% style="width:676px" %)A service for receiving archived data from A1800 meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_232.bin 125 -| |(% style="width:214px" %)sed_rtu_over_tcp_a1800_rtd|(% style="width:676px" %)A service for receiving real-time data from A1800 meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_231.bin 126 -| |(% style="width:214px" %)sed_rtu_over_tcp_acron_arch|(% style="width:676px" %)A service for receiving archived data from Acron meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_142.bin 127 -| |(% style="width:214px" %)sed_rtu_over_tcp_acron_rtd|(% style="width:676px" %)A service for receiving real-time data from Acron meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_141.bin 128 -| |(% style="width:214px" %)sed_rtu_over_tcp_bmrz_waveform|(% style="width:676px" %)A service for reading waveform files from BMRZ terminals using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_110.bin 129 -| |(% style="width:214px" %)sed_rtu_over_tcp_bzp03_waveform|(% style="width:676px" %)A service for reading waveform files from BZP-03 terminals using Modbus RTU over TCP protocol|(% style="width:358px" %) 130 -| |(% style="width:214px" %)sed_rtu_over_tcp_kmp_rtd|(% style="width:676px" %)A service for polling Multitical 601 device using the KMP protocol|(% style="width:358px" %)sed_metrology_191.bin 131 -| |(% style="width:214px" %)sed_rtu_over_tcp_majac_arch|(% style="width:676px" %)A service for receiving archived data from devices using the Mayak protocol|(% style="width:358px" %)sed_metrology_152.bin 132 -| |(% style="width:214px" %)sed_rtu_over_tcp_mercury200_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the Mercury 200 protocol|(% style="width:358px" %)sed_metrology_251.bin 133 -| |(% style="width:214px" %)sed_rtu_over_tcp_mercury_arch|(% style="width:676px" %)A service for reading archives and event logs from Mercury-230 series devices using the Mercury-230 protocol|(% style="width:358px" %)sed_metrology_202.bin 134 -| |(% style="width:214px" %)sed_rtu_over_tcp_mercury_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the Mercury 230 protocol|(% style="width:358px" %)sed_metrology_201.bin 135 -| |(% style="width:214px" %)sed_rtu_over_tcp_photon_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the photon RTU over TCP protocol|(% style="width:358px" %)sed_metrology_221.bin 136 -| |(% style="width:214px" %)sed_rtu_over_tcp_ref542plus_waveform|(% style="width:676px" %)Proofreading of waveforms and time synchronization via Modbus RTU over TCP protocol from ABB REF 542plus devices|(% style="width:358px" %) 137 -| |(% style="width:214px" %)sed_rtu_over_tcp_set4tm_arch|(% style="width:676px" %)A service for polling SET-4TM, PSC meters’ archives|(% style="width:358px" %)sed_metrology_112.bin 138 -| |(% style="width:214px" %)sed_rtu_over_tcp_set4tm_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the SET-4TM rtu over tcp protocol|(% style="width:358px" %)sed_metrology_111.bin 139 -| |(% style="width:214px" %)sed_rtu_over_tcp_tem104_arch|(% style="width:676px" %)A service for receiving archived data from devices using the TEM104 protocol|(% style="width:358px" %)sed_metrology_162.bin 140 -| |(% style="width:214px" %)sed_rtu_over_tcp_tem104_rtd|(% style="width:676px" %)A service for receiving real-tume data from devices using the TEM104 protocol|(% style="width:358px" %)sed_metrology_161.bin 141 -| |(% style="width:214px" %)sed_rtu_over_tcp_vist_arch|(% style="width:676px" %)A service for receiving archived data from devices using the VIS.T protocol|(% style="width:358px" %)sed_metrology_172.bin 142 -| |(% style="width:214px" %)sed_rtu_over_tcp_vkt5_arch|(% style="width:676px" %)A service for receiving archived data from VKT-5 devices|(% style="width:358px" %)sed_metrology_312.bin 143 -| |(% style="width:214px" %)sed_rtu_over_tcp_vkt5_rtd|(% style="width:676px" %)A service for receiving real-time data from VKT-5 devices|(% style="width:358px" %)sed_metrology_311.bin 144 -| |(% style="width:214px" %)sed_vkt7_arch|(% style="width:676px" %)A service for receiving archived data from VKT-7 devices|(% style="width:358px" %) 145 -| |(% style="width:214px" %)sed_vkt7_rtd|(% style="width:676px" %)A service for receiving real-time data from VKT-7 devices|(% style="width:358px" %) 146 -| |(% style="width:214px" %)sed_rtu_over_tcp_vtd_arch|(% style="width:676px" %)A service for receiving archived data of VTD devices|(% style="width:358px" %)sed_metrology_182.bin 147 -| |(% style="width:214px" %)sed_rtu_over_tcp_vtd_rtd|(% style="width:676px" %)A service for receiving operational data from VTD devices|(% style="width:358px" %)sed_metrology_181.bin 148 -| |(% style="width:214px" %)sed_uvp_arch|(% style="width:676px" %)A service for poling Promavtomatika's archive for devices of the UVP series|(% style="width:358px" %)sed_metrology_352.bin 149 -| |(% style="width:214px" %)sed_ce_arch|(% style="width:676px" %)A service for receiving archived data from Energomera devices of the CE series according to the IEC61107 protocol|(% style="width:358px" %)sed_metrology_362.bin 150 -| |(% style="width:214px" %)sed_alpha_arch|(% style="width:676px" %)A service for receiving archived data from Alfa-3 devices manufactured by Alfamera|(% style="width:358px" %)sed_metrology_462_472.bin 151 -| |(% style="width:214px" %)sed_bug01_rtd|(% style="width:676px" %)A service for receiving archived data of BUG-01 devices|(% style="width:358px" %)sed_metrology_491.bin 152 -| |(% style="width:214px" %)sed_dymetic_arch|(% style="width:676px" %)A service for receiving archived data from Dimetik|(% style="width:358px" %)sed_metrology_552.bin 153 -| |(% style="width:214px" %)sed_irvis_arch|(% style="width:676px" %)A service for receiving archived data from devices using the Irvis protocol|(% style="width:358px" %)sed_metrology_442.bin 154 -| |(% style="width:214px" %)sed_karat_arch|(% style="width:676px" %)A service for receiving archived data from Karat devices|(% style="width:358px" %)sed_metrology_512.bin 155 -| |(% style="width:214px" %)sed_lis200_arch|(% style="width:676px" %)A service for receiving archived data from the EK-260 and EK-270 devices manufactured by Elster|(% style="width:358px" %)sed_metrology_452.bin 156 -| |(% style="width:214px" %)sed_rtu_over_tcp_sepam_waveform|(% style="width:676px" %)A service for reading waveform files from Sepam devices using Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_298.bin 157 -|(% colspan="4" style="text-align:center" %)**Data export and import services in SQL databases** 158 -| |(% style="width:214px" %)sed_sql_rtd|(% style="width:676px" %)A service for receiving tele-measurement data from MySQL|(% style="width:358px" %)sed_metrology_211.bin 159 -| |(% style="width:214px" %)sed_sql_arch|(% style="width:676px" %)A service for archived data retrieval from Microsoft SQL Server|(% style="width:358px" %) 160 -| |(% style="width:214px" %)sed_sql_arch_send|(% style="width:676px" %)A service for recording archived data in an external SQL database|(% style="width:358px" %) 161 -|(% colspan="4" style="text-align:center" %)**Data processing services** 94 +1. 95 +)))|sed_s2s_configuration|Configuration transmission service between CENTO servers| 96 +|(% colspan="4" %)**Data collection and transmission services using standard protocols** 162 162 |((( 163 163 1. 164 -)))| (%style="width:214px" %)sed_controller|(%style="width:676px" %)A service fortelemetryreceptionandprocessing(writes totheInfluxDBdatabase)|(%style="width:358px"%)sed_metrology_controller.bin99 +)))|sed_modbus_rtd|A service for reading real-time data from devices using Modbus protocol (Modbus TCP and Modbus RTU over TCP)|sed_metrology_001.bin 165 165 |((( 166 166 1. 167 -)))| (%style="width:214px" %)sed_events_calc|(%style="width:676px" %)A service forgenerating event based onthe conditionsspecifiedin theconfiguration|(%style="width:358px" %)102 +)))|sed_modbus_rtd_send|A service for sending real-time data to third-party devices using the Modbus TCP protocol| 168 168 |((( 169 169 1. 170 -)))|(% style="width:214px" %)sed_calc_arch|(% style="width:676px" %)A service for calculating metering channels|(% style="width:358px" %)((( 105 +)))|sed_modbus_sync|A device time synchronization service using Modbus protocol (Modbus TCP and Modbus RTU over TCP)| 106 +|((( 107 +1. 108 +)))|sed_snmp_rtd|A service for reading real-time data from devices using the SNMP (v1, v2c, v3), ICMP protocols| 109 +|((( 110 +1. 111 +)))|sed_iec103_waveform|A service for reading waveform files from devices using the IEC protocol-60870-5-103|sed_metrology_393.bin 112 +|((( 113 +1. 114 +)))|sed_iec104_rtd|A service for reading real-time data from devices using the IEC 60870-5-104 protocol|sed_metrology_011.bin 115 +|((( 116 +1. 117 +)))|sed_iec104_rtd_send|A service for sending real-time data to third-party devices using the IEC 60870-5-104 protocol|sed_metrology_012.bin 118 +|((( 119 +1. 120 +)))|sed_opcda_rtd|A service for receiving real-time data using the OPC DA protocol| 121 +|((( 122 +1. 123 +)))|sed_opcua_rtd|A service for receiving real-time data using the OPC UA protocol| 124 +|((( 125 +1. 126 +)))|sed_opcua_arch|A service for receiving archived data using the OPC UA protocol|sed_metrology_402.bin 127 +|((( 128 +1. 129 +)))|sed_opcua_server|A service for transmitting data using the OPC UA protocol| 130 +|((( 131 +1. 132 +)))|sed_dnp3_rtd|A service for reading real-time data from devices using the DNP3 protocol| 133 +|((( 134 +1. 135 +)))|sed_ftp_waveform|A service for receiving waveform files via FTP protocol|sed_metrology_380.bin 136 +|((( 137 +1. 138 +)))|sed_iec61107_rtd|A service for obtaining real-time data from devices using the IEC 62056-21 protocol|sed_metrology_61107.bin 139 +|((( 140 +1. 141 +)))|sed_iec61850_arch|A service for receiving archived data from devices using the IEC 61850 protocol| 142 +|((( 143 +1. 144 +)))|sed_iec61850_rtd|A service for receiving operational data from devices using the IEC 61850 protocol| 145 +|(% colspan="4" %)**Proprietary protocol data collection and transmission services** 146 +|((( 147 +1. 148 +)))|sed_satec_arch|A service for reading archived data (metering and event logs) from SATEC devices|sed_metrology_7_8.bin 149 +|((( 150 +1. 151 +)))|sed_satec_pq_journal|A service for obtaining event logs for monitoring the power quality from Satec devices|sed_metrology_106.bin 152 +|((( 153 +1. 154 +)))|sed_satec_pq_report|A service for receiving reports on the power quality control from Satec devices|sed_metrology_106.bin 155 +|((( 156 +1. 157 +)))|sed_satec_waveforms|A service for proofreading waveforms from SATEC devices using Modbus TCP and RTU over TCP protocols|sed_metrology_108_109.bin 158 +|((( 159 +1. 160 +)))|sed_iec103_rtd|A service for reading real-time data from TOR 200 terminals according to the IEC protocol-60870-5-103|sed_metrology_391.bin 161 +|((( 162 +1. 163 +)))|sed_sepam_waveform|A service for proofreading waveforms and time synchronization using the Modbus RTU over TCP protocol from Sepam devices|sed_metrology_298_299.bin 164 +|((( 165 +1. 166 +)))|sed_rtu_over_tcp_logikamp_rtd|A service for reading real-time data from devices using the LogicaMP RTU over TCP protocol|sed_metrology_121.bin 167 +|((( 168 +1. 169 +)))|sed_rtu_over_tcp_logikamp_arch|A service for reading archived data from devices using the LogicaMP RTU over TCP protocol|sed_metrology_122.bin 170 +|((( 171 +1. 172 +)))|sed_axis_video_journal|An AXIS camera recording service|sed_metrology_435.bin 173 +|((( 174 +1. 175 +)))|sed_vzlyotmb_arch|A service for reading archives and event logs of devices Vzlet TSRV-043, TSRV-027, IVK-TER|sed_metrology_25_133.bin 176 +|((( 177 +1. 178 +)))|sed_micom_waveforms|A service for reading waveform files from Micom devices using Modbus RTU over TCP protocol|sed_metrology_370.bin 179 +|((( 180 +1. 181 +)))|sed_pulsar_arch|A service for reading archives from Pulsar devices using the Modbus protocol|sed_metrology_342.bin 182 +|((( 183 +1. 184 +)))|sed_rtu_over_tcp_a1800_arch|A service for receiving archived data from A1800 meters using the Modbus RTU over TCP protocol|sed_metrology_232.bin 185 +|((( 186 +1. 187 +)))|sed_rtu_over_tcp_a1800_rtd|A service for receiving real-time data from A1800 meters using the Modbus RTU over TCP protocol|sed_metrology_231.bin 188 +|((( 189 +1. 190 +)))|sed_rtu_over_tcp_acron_arch|A service for receiving archived data from Acron meters using the Modbus RTU over TCP protocol|sed_metrology_142.bin 191 +|((( 192 +1. 193 +)))|sed_rtu_over_tcp_acron_rtd|A service for receiving real-time data from Acron meters using the Modbus RTU over TCP protocol|sed_metrology_141.bin 194 +|((( 195 +1. 196 +)))|sed_rtu_over_tcp_bmrz_waveform|A service for reading waveform files from BMRZ terminals using the Modbus RTU over TCP protocol|sed_metrology_110.bin 197 +|((( 198 +1. 199 +)))|sed_rtu_over_tcp_bzp03_waveform|A service for reading waveform files from BZP-03 terminals using Modbus RTU over TCP protocol| 200 +|((( 201 +1. 202 +)))|sed_rtu_over_tcp_kmp_rtd|A service for polling Multitical 601 device using the KMP protocol|sed_metrology_191.bin 203 +|((( 204 +1. 205 +)))|sed_rtu_over_tcp_majac_arch|A service for receiving archived data from devices using the Mayak protocol|sed_metrology_152.bin 206 +|((( 207 +1. 208 +)))|sed_rtu_over_tcp_mercury200_rtd|A service for receiving real-time data from devices using the Mercury 200 protocol|sed_metrology_251.bin 209 +|((( 210 +1. 211 +)))|sed_rtu_over_tcp_mercury_arch|A service for reading archives and event logs from Mercury-230 series devices using the Mercury-230 protocol|sed_metrology_202.bin 212 +|((( 213 +1. 214 +)))|sed_rtu_over_tcp_mercury_rtd|A service for receiving real-time data from devices using the Mercury 230 protocol|sed_metrology_201.bin 215 +|((( 216 +1. 217 +)))|sed_rtu_over_tcp_photon_rtd|A service for receiving real-time data from devices using the photon RTU over TCP protocol|sed_metrology_221.bin 218 +|((( 219 +1. 220 +)))|sed_rtu_over_tcp_ref542plus_waveform|Proofreading of waveforms and time synchronization via Modbus RTU over TCP protocol from ABB REF 542plus devices| 221 +|((( 222 +1. 223 +)))|sed_rtu_over_tcp_set4tm_arch|A service for polling SET-4TM, PSC meters’ archives|sed_metrology_112.bin 224 +|((( 225 +1. 226 +)))|sed_rtu_over_tcp_set4tm_rtd|A service for receiving real-time data from devices using the SET-4TM rtu over tcp protocol|sed_metrology_111.bin 227 +|((( 228 +1. 229 +)))|sed_rtu_over_tcp_tem104_arch|A service for receiving archived data from devices using the TEM104 protocol|sed_metrology_162.bin 230 +|((( 231 +1. 232 +)))|sed_rtu_over_tcp_tem104_rtd|A service for receiving real-tume data from devices using the TEM104 protocol|sed_metrology_161.bin 233 +|((( 234 +1. 235 +)))|sed_rtu_over_tcp_vist_arch|A service for receiving archived data from devices using the VIS.T protocol|sed_metrology_172.bin 236 +|((( 237 +1. 238 +)))|sed_rtu_over_tcp_vkt5_arch|A service for receiving archived data from VKT-5 devices|sed_metrology_312.bin 239 +|((( 240 +1. 241 +)))|sed_rtu_over_tcp_vkt5_rtd|A service for receiving real-time data from VKT-5 devices|sed_metrology_311.bin 242 +|((( 243 +1. 244 +)))|sed_vkt7_arch|A service for receiving archived data from VKT-7 devices| 245 +|((( 246 +1. 247 +)))|sed_vkt7_rtd|A service for receiving real-time data from VKT-7 devices| 248 +|((( 249 +1. 250 +)))|sed_rtu_over_tcp_vtd_arch|A service for receiving archived data of VTD devices|sed_metrology_182.bin 251 +|((( 252 +1. 253 +)))|sed_rtu_over_tcp_vtd_rtd|A service for receiving operational data from VTD devices|sed_metrology_181.bin 254 +|((( 255 +1. 256 +)))|sed_uvp_arch|A service for poling Promavtomatika's archive for devices of the UVP series|sed_metrology_352.bin 257 +|((( 258 +1. 259 +)))|sed_ce_arch|A service for receiving archived data from Energomera devices of the CE series according to the IEC61107 protocol|sed_metrology_362.bin 260 +|((( 261 +1. 262 +)))|sed_alpha_arch|A service for receiving archived data from Alfa-3 devices manufactured by Alfamera|sed_metrology_462_472.bin 263 +|((( 264 +1. 265 +)))|sed_bug01_rtd|A service for receiving archived data of BUG-01 devices|sed_metrology_491.bin 266 +|((( 267 +1. 268 +)))|sed_dymetic_arch|A service for receiving archived data from Dimetik|sed_metrology_552.bin 269 +|((( 270 +1. 271 +)))|sed_irvis_arch|A service for receiving archived data from devices using the Irvis protocol|sed_metrology_442.bin 272 +|((( 273 +1. 274 +)))|sed_karat_arch|A service for receiving archived data from Karat devices|sed_metrology_512.bin 275 +|((( 276 +1. 277 +)))|sed_lis200_arch|A service for receiving archived data from the EK-260 and EK-270 devices manufactured by Elster|sed_metrology_452.bin 278 +|((( 279 +1. 280 +)))|sed_rtu_over_tcp_sepam_waveform|A service for reading waveform files from Sepam devices using Modbus RTU over TCP protocol|sed_metrology_298.bin 281 +|(% colspan="4" %)**Data export and import services in SQL databases** 282 +|((( 283 +1. 284 +)))|sed_sql_rtd|A service for receiving tele-measurement data from MySQL|sed_metrology_211.bin 285 +|((( 286 +1. 287 +)))|sed_sql_arch|A service for archived data retrieval from Microsoft SQL Server| 288 +|((( 289 +1. 290 +)))|sed_sql_arch_send|A service for recording archived data in an external SQL database| 291 +|(% colspan="4" %)**Data processing services** 292 +|((( 293 +1. 294 +)))|sed_controller|A service for telemetry reception and processing (writes to the InfluxDB database)|sed_metrology_controller.bin 295 +|((( 296 +1. 297 +)))|sed_events_calc|A service for generating event based on the conditions specified in the configuration| 298 +|((( 299 +1. 300 +)))|sed_calc_arch|A service for calculating metering channels|((( 171 171 sed_metrology_calc_arch.bin 172 172 173 173 sed_metrology_formulas.bin ... ... @@ -174,208 +174,208 @@ 174 174 ))) 175 175 |((( 176 176 1. 177 -)))| (%style="width:214px" %)sed_calc_rtd|(% style="width:676px" %)A service for calculating pre-calculated tags|(%style="width:358px" %)307 +)))|sed_calc_rtd|A service for calculating pre-calculated tags| 178 178 |((( 179 179 1. 180 -)))| (%style="width:214px" %)sed_round_arch|(% style="width:676px" %)A service for calculating metering channels with rounding|(%style="width:358px" %)sed_metrology_round_arch.bin310 +)))|sed_round_arch|A service for calculating metering channels with rounding|sed_metrology_round_arch.bin 181 181 |((( 182 182 1. 183 -)))| (%style="width:214px" %)sed_energy_calc|(% style="width:676px" %)A service for server-level energy resource calculation|(%style="width:358px" %)sed_metrology_411_421.bin313 +)))|sed_energy_calc|A service for server-level energy resource calculation|sed_metrology_411_421.bin 184 184 |((( 185 185 1. 186 -)))| (%style="width:214px" %)sed_loadflow_calc|(% style="width:676px" %)A service for calculating modes based on an information model|(%style="width:358px" %)316 +)))|sed_loadflow_calc|A service for calculating modes based on an information model| 187 187 |((( 188 188 1. 189 -)))| (%style="width:214px" %)sed_storage_writer|(% style="width:676px" %)A service for recording archived data (metering and event logs) in a data storage (InfluxDB and MongoDB)|(%style="width:358px" %)319 +)))|sed_storage_writer|A service for recording archived data (metering and event logs) in a data storage (InfluxDB and MongoDB)| 190 190 |(% colspan="4" %)**Web Part Services** 191 191 |((( 192 192 1. 193 -)))| (% style="width:214px" %)php5-cgi|(% style="width:676px" %)A Web Query Service|(%style="width:358px" %)323 +)))|php5-cgi|A Web Query Service| 194 194 |((( 195 195 1. 196 -)))| (% style="width:214px" %)nginx|(% style="width:676px" %)A Web Server|(%style="width:358px" %)326 +)))|nginx|A Web Server| 197 197 |((( 198 198 1. 199 -)))| (%style="width:214px" %)sed_ui|(% style="width:676px" %)A service for processing requests for web resources (js, css, html files)|(%style="width:358px" %)329 +)))|sed_ui|A service for processing requests for web resources (js, css, html files)| 200 200 |((( 201 201 1. 202 -)))| (%style="width:214px" %)sed_rtd_analysis|(% style="width:676px" %)A service for analyzing real-time data|(%style="width:358px" %)332 +)))|sed_rtd_analysis|A service for analyzing real-time data| 203 203 |((( 204 204 1. 205 -)))| (%style="width:214px" %)sed_auth|(% style="width:676px" %)A service for authenticating and authorizing users in the system and configuring access rights|(%style="width:358px" %)335 +)))|sed_auth|A service for authenticating and authorizing users in the system and configuring access rights| 206 206 |((( 207 207 1. 208 -)))| (%style="width:214px" %)sed_auth_privileges|(% style="width:676px" %)A User Privilege Management Service|(%style="width:358px" %)338 +)))|sed_auth_privileges|A User Privilege Management Service| 209 209 |((( 210 210 1. 211 -)))| (%style="width:214px" %)sed_api_gateway|(% style="width:676px" %)A service for proxying of web requests to other services within the system|(%style="width:358px" %)341 +)))|sed_api_gateway|A service for proxying of web requests to other services within the system| 212 212 |((( 213 213 1. 214 -)))| (%style="width:214px" %)sed_dataset_configurator|(% style="width:676px" %)A service for working with datasets|(%style="width:358px" %)344 +)))|sed_dataset_configurator|A service for working with datasets| 215 215 |((( 216 216 1. 217 -)))| (%style="width:214px" %)sed_rtd|(% style="width:676px" %)A real-time data subscription service|(%style="width:358px" %)347 +)))|sed_rtd|A real-time data subscription service| 218 218 |((( 219 219 1. 220 -)))| (%style="width:214px" %)sed_rtd_archive|(% style="width:676px" %)A service for generating archived data from real-time data|(%style="width:358px" %)350 +)))|sed_rtd_archive|A service for generating archived data from real-time data| 221 221 |((( 222 222 1. 223 -)))| (%style="width:214px" %)sed_system|(% style="width:676px" %)A service that provides a user interface with information about the system|(%style="width:358px" %)353 +)))|sed_system|A service that provides a user interface with information about the system| 224 224 |((( 225 225 1. 226 -)))| (%style="width:214px" %)sed_archive|(% style="width:676px" %)A service that provides user interfaces for analyzing electricity and energy accounting|(%style="width:358px" %)356 +)))|sed_archive|A service that provides user interfaces for analyzing electricity and energy accounting| 227 227 |((( 228 228 1. 229 -)))| (%style="width:214px" %)sed_archive_integrity|(% style="width:676px" %)A service that provides user interfaces for analyzing the completeness of electricity and energy resources data|(%style="width:358px" %)359 +)))|sed_archive_integrity|A service that provides user interfaces for analyzing the completeness of electricity and energy resources data| 230 230 |((( 231 231 1. 232 -)))| (%style="width:214px" %)sed_pq_reports|(% style="width:676px" %)A service for working with power quality reports|(%style="width:358px" %)362 +)))|sed_pq_reports|A service for working with power quality reports| 233 233 |((( 234 234 1. 235 -)))| (%style="width:214px" %)sed_pq_journal|(% style="width:676px" %)A service for working with power quality logs|(%style="width:358px" %)365 +)))|sed_pq_journal|A service for working with power quality logs| 236 236 |((( 237 237 1. 238 -)))| (%style="width:214px" %)sed_ras_configurator|(% style="width:676px" %)A service for configuring emergency event loggers|(%style="width:358px" %)368 +)))|sed_ras_configurator|A service for configuring emergency event loggers| 239 239 |((( 240 240 1. 241 -)))| (%style="width:214px" %)sed_reports|(% style="width:676px" %)A service for generating and managing reports, and maintaining user interfaces for reports|(%style="width:358px" %)371 +)))|sed_reports|A service for generating and managing reports, and maintaining user interfaces for reports| 242 242 |((( 243 243 1. 244 -)))| (%style="width:214px" %)sed_widgets|(% style="width:676px" %)A service for the user interfaces of drag'n'drop widgets|(%style="width:358px" %)374 +)))|sed_widgets|A service for the user interfaces of drag'n'drop widgets| 245 245 |((( 246 246 1. 247 -)))| (%style="width:214px" %)sed_menu|(% style="width:676px" %)A service for displaying and configuring CENTO system menu|(%style="width:358px" %)377 +)))|sed_menu|A service for displaying and configuring CENTO system menu| 248 248 |((( 249 249 1. 250 -)))| (%style="width:214px" %)sed_mnemonic_diagrams|(% style="width:676px" %)A service for the user interfaces of diagrams v2|(%style="width:358px" %)380 +)))|sed_mnemonic_diagrams|A service for the user interfaces of diagrams v2| 251 251 |((( 252 252 1. 253 -)))| (%style="width:214px" %)sed_configuration|(% style="width:676px" %)A service for user interfaces for system configuration (alerts, mail servers, formulas, device trees)|(%style="width:358px" %)383 +)))|sed_configuration|A service for user interfaces for system configuration (alerts, mail servers, formulas, device trees)| 254 254 |((( 255 255 1. 256 -)))| (%style="width:214px" %)sed_devices_configurator|(% style="width:676px" %)A service for editing device configurations, tags, and channels|(%style="width:358px" %)386 +)))|sed_devices_configurator|A service for editing device configurations, tags, and channels| 257 257 |((( 258 258 1. 259 -)))| (%style="width:214px" %)sed_common_event_journal|(% style="width:676px" %)A service for user interfaces for generalized configurable event logs|(%style="width:358px" %)389 +)))|sed_common_event_journal|A service for user interfaces for generalized configurable event logs| 260 260 |((( 261 261 1. 262 -)))| (%style="width:214px" %)sed_device_event_journal|(% style="width:676px" %)A Device Log Service|(%style="width:358px" %)392 +)))|sed_device_event_journal|A Device Log Service| 263 263 |((( 264 264 1. 265 -)))| (%style="width:214px" %)sed_operative_journal|(% style="width:676px" %)A service for the user interface of the real-time event log|(%style="width:358px" %)395 +)))|sed_operative_journal|A service for the user interface of the real-time event log| 266 266 |((( 267 267 1. 268 -)))| (%style="width:214px" %)sed_video_journal|(% style="width:676px" %)A Video Camera Log Service|(%style="width:358px" %)398 +)))|sed_video_journal|A Video Camera Log Service| 269 269 |((( 270 270 1. 271 -)))| (%style="width:214px" %)sed_marking|(% style="width:676px" %)A Dispatch Tag Management Service|(%style="width:358px" %)401 +)))|sed_marking|A Dispatch Tag Management Service| 272 272 |((( 273 273 1. 274 -)))| (%style="width:214px" %)sed_sounds|(% style="width:676px" %)A service for the user interface for sound alerts management|(%style="width:358px" %)404 +)))|sed_sounds|A service for the user interface for sound alerts management| 275 275 |((( 276 276 1. 277 -)))| (%style="width:214px" %)sed_video_stream|(% style="width:676px" %)A service for streaming video from cameras registered in the information model|(%style="width:358px" %)407 +)))|sed_video_stream|A service for streaming video from cameras registered in the information model| 278 278 |(% colspan="4" %)**System services** 279 279 |((( 280 280 1. 281 -)))| (% style="width:214px" %)nats|(% style="width:676px" %)A message broker and a service registry (service registry/service discovery)|(%style="width:358px" %)411 +)))|nats|A message broker and a service registry (service registry/service discovery)| 282 282 |((( 283 283 1. 284 -)))| (% style="width:214px" %)influxdb|(% style="width:676px" %)A time series database|(%style="width:358px" %)414 +)))|influxdb|A time series database| 285 285 |((( 286 286 1. 287 -)))| (% style="width:214px" %)mongod|(% style="width:676px" %)A database of configuration and structured data (event logs, requests)|(%style="width:358px" %)417 +)))|mongod|A database of configuration and structured data (event logs, requests)| 288 288 |((( 289 289 1. 290 -)))| (%style="width:214px" %)sed_signals|(% style="width:676px" %)A signal reception and transmission service inside the system (remote control, configuration update, manual polling, parameter recalculation)|(%style="width:358px" %)420 +)))|sed_signals|A signal reception and transmission service inside the system (remote control, configuration update, manual polling, parameter recalculation)| 291 291 |((( 292 292 1. 293 -)))| (%style="width:214px" %)sed_debug|(% style="width:676px" %)A service for providing access to debugging information of CENTO services|(%style="width:358px" %)423 +)))|sed_debug|A service for providing access to debugging information of CENTO services| 294 294 |((( 295 295 1. 296 -)))| (%style="width:214px" %)sed_graphql|(% style="width:676px" %)A subscription service for device statuses|(%style="width:358px" %)426 +)))|sed_graphql|A subscription service for device statuses| 297 297 |((( 298 298 1. 299 -)))| (%style="width:214px" %)sed_energy_calc_configuration|(% style="width:676px" %)A service for creating, changing, and deleting energy resource calculation configurations at the server level|(%style="width:358px" %)429 +)))|sed_energy_calc_configuration|A service for creating, changing, and deleting energy resource calculation configurations at the server level| 300 300 |((( 301 301 1. 302 -)))| (%style="width:214px" %)sed_backup|(% style="width:676px" %)A service for backing up data according to the cron rule.|(%style="width:358px" %)432 +)))|sed_backup|A service for backing up data according to the cron rule.| 303 303 |((( 304 304 1. 305 -)))| (%style="width:214px" %)sed_channels|(% style="width:676px" %)A channel subscription service|(%style="width:358px" %)435 +)))|sed_channels|A channel subscription service| 306 306 |((( 307 307 1. 308 -)))| (%style="width:214px" %)sed_channels_data|(% style="width:676px" %)A subscription service for protocol statuses and the latest channel data|(%style="width:358px" %)438 +)))|sed_channels_data|A subscription service for protocol statuses and the latest channel data| 309 309 |((( 310 310 1. 311 -)))| (%style="width:214px" %)sed_emission_archive|(% style="width:676px" %)A service for providing emissions metering data|(%style="width:358px" %)441 +)))|sed_emission_archive|A service for providing emissions metering data| 312 312 |((( 313 313 1. 314 -)))| (%style="width:214px" %)sed_profile_archive|(% style="width:676px" %)A service for providing metering data from InfluxDB via gRPC.|(%style="width:358px" %)444 +)))|sed_profile_archive|A service for providing metering data from InfluxDB via gRPC.| 315 315 |((( 316 316 1. 317 -)))| (%style="width:214px" %)sed_web_storage|(% style="width:676px" %)A service for accessing archived metering data|(%style="width:358px" %)447 +)))|sed_web_storage|A service for accessing archived metering data| 318 318 |((( 319 319 1. 320 -)))| (%style="width:214px" %)sed_watchdog|(% style="width:676px" %)A service for managing the launch of CENTO services|(%style="width:358px" %)450 +)))|sed_watchdog|A service for managing the launch of CENTO services| 321 321 |((( 322 322 1. 323 -)))| (%style="width:214px" %)sed_scheduler|(% style="width:676px" %)A service for launching scheduled tasks|(%style="width:358px" %)453 +)))|sed_scheduler|A service for launching scheduled tasks| 324 324 |((( 325 325 1. 326 -)))| (%style="width:214px" %)sed_license|(% style="width:676px" %)A licensing service|(%style="width:358px" %)456 +)))|sed_license|A licensing service| 327 327 |((( 328 328 1. 329 -)))| (%style="width:214px" %)sed_monitor|(% style="width:676px" %)A service for monitoring the operation of the system's services and applications|(%style="width:358px" %)459 +)))|sed_monitor|A service for monitoring the operation of the system's services and applications| 330 330 |((( 331 331 1. 332 -)))| (%style="width:214px" %)sed_telecontrol|(% style="width:676px" %)A remote control service|(%style="width:358px" %)462 +)))|sed_telecontrol|A remote control service| 333 333 |((( 334 334 1. 335 -)))| (%style="width:214px" %)sed_notificator|(% style="width:676px" %)A service for notifying users about events by e-mail|(%style="width:358px" %)465 +)))|sed_notificator|A service for notifying users about events by e-mail| 336 336 |((( 337 337 1. 338 -)))| (%style="width:214px" %)sed_waveforms_journal|(% style="width:676px" %)A waveform Log Service|(%style="width:358px" %)468 +)))|sed_waveforms_journal|A waveform Log Service| 339 339 |((( 340 340 1. 341 -)))| (%style="width:214px" %)sed_storage_configurator|(% style="width:676px" %)An InfluxDB Database Configuration Service|(%style="width:358px" %)471 +)))|sed_storage_configurator|An InfluxDB Database Configuration Service| 342 342 |((( 343 343 1. 344 -)))| (%style="width:214px" %)sed_system_configuration|(% style="width:676px" %)A CENTO System Configuration Editing Service|(%style="width:358px" %)474 +)))|sed_system_configuration|A CENTO System Configuration Editing Service| 345 345 |((( 346 346 1. 347 -)))| (%style="width:214px" %)sed_user_settings|(% style="width:676px" %)A User Settings Configuration Service|(%style="width:358px" %)477 +)))|sed_user_settings|A User Settings Configuration Service| 348 348 |((( 349 349 1. 350 -)))| (%style="width:214px" %)sed_system_event_journal|(% style="width:676px" %)A service for registration and provision of system events (business logic and administration)|(%style="width:358px" %)480 +)))|sed_system_event_journal|A service for registration and provision of system events (business logic and administration)| 351 351 |((( 352 352 1. 353 -)))| (%style="width:214px" %)sed_tech_event_journal|(% style="width:676px" %)A service for processing and managing technological events|(%style="width:358px" %)483 +)))|sed_tech_event_journal|A service for processing and managing technological events| 354 354 |((( 355 355 1. 356 -)))| (%style="width:214px" %)sed_information_model|(% style="width:676px" %)A System Information Model Management Service|(%style="width:358px" %)486 +)))|sed_information_model|A System Information Model Management Service| 357 357 |((( 358 358 1. 359 -)))| (%style="width:214px" %)sed_events_configurator|(% style="width:676px" %)A System Event Configuration Service|(%style="width:358px" %)489 +)))|sed_events_configurator|A System Event Configuration Service| 360 360 |((( 361 361 1. 362 -)))| (%style="width:214px" %)sed_information_model_editor|(% style="width:676px" %)A service for editing the information model|(%style="width:358px" %)492 +)))|sed_information_model_editor|A service for editing the information model| 363 363 |(% colspan="4" %)**Server Backup Services** 364 364 |((( 365 365 1. 366 -)))| (%style="width:214px" %)sed_coordinator|(% style="width:676px" %)A service for selecting the cluster's host server using the Bully leader election algorithm|(%style="width:358px" %)496 +)))|sed_coordinator|A service for selecting the cluster's host server using the Bully leader election algorithm| 367 367 |((( 368 368 1. 369 -)))| (%style="width:214px" %)sed_reserve|(% style="width:676px" %)A service for displaying a list of backup servers|(%style="width:358px" %)499 +)))|sed_reserve|A service for displaying a list of backup servers| 370 370 |((( 371 371 1. 372 -)))| (%style="width:214px" %)sed_replicator|(% style="width:676px" %)A log replication service between cluster servers|(%style="width:358px" %)502 +)))|sed_replicator|A log replication service between cluster servers| 373 373 |((( 374 374 1. 375 -)))| (%style="width:214px" %)sed_influx_replicator|(% style="width:676px" %)A data replication service (archives and telemetry) between cluster servers|(%style="width:358px" %)505 +)))|sed_influx_replicator|A data replication service (archives and telemetry) between cluster servers| 376 376 |((( 377 377 1. 378 -)))| (%style="width:214px" %)sed_events_replicator|(% style="width:676px" %)An event replication service between cluster servers|(%style="width:358px" %)508 +)))|sed_events_replicator|An event replication service between cluster servers| 379 379 |((( 380 380 1. 381 -)))| (%style="width:214px" %)sed_fs_synch|(% style="width:676px" %)A data replication service (gob files, reports, waveforms) between cluster servers|(%style="width:358px" %)511 +)))|sed_fs_synch|A data replication service (gob files, reports, waveforms) between cluster servers|