Changes for page 4. Structure and Modules Description
Last modified by Iaroslav Platonov on 2026/06/08 10:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -74,404 +74,4 @@ 74 74 75 75 Table 1 – CENTO software components 76 76 77 -|(% style="text-align:center" %)**№**|(% style="text-align:center; width:214px" %)**Service Name**|(% style="text-align:center; width:676px" %)**Function**|(% style="text-align:center; width:358px" %)**Metrologically significant part** 78 -|(% colspan="4" style="text-align:center" %)**Data collection and transmission services** 79 -|((( 80 -~1. 81 -)))|(% style="width:214px" %)sed_bus_dispatcher|(% style="width:676px" %)Sequential Device Polling Management Service|(% style="width:358px" %) 82 -|((( 83 -2. 84 -)))|(% style="width:214px" %)sed_xml_reader|(% style="width:676px" %)Service for processing received XML files 80020|(% style="width:358px" %) 85 -|((( 86 -3. 87 -)))|(% style="width:214px" %)sed_xml_send|(% style="width:676px" %)XML file transfer Service 80020|(% style="width:358px" %) 88 -|((( 89 -4. 90 -)))|(% style="width:214px" %)sed_archive_webapi|(% style="width:676px" %)Implementation of the web API for transmitting archived data according to the CENTO documentation|(% style="width:358px" %) 91 -|((( 92 -5. 93 -)))|(% style="width:214px" %)sed_s2s_configuration|(% style="width:676px" %)Configuration transmission service between CENTO servers|(% style="width:358px" %) 94 -|(% colspan="4" style="text-align:center" %)**Data collection and transmission services using standard protocols** 95 -|6.|(% style="width:214px" %)sed_modbus_rtd|(% style="width:676px" %)A service for reading real-time data from devices using Modbus protocol (Modbus TCP and Modbus RTU over TCP)|(% style="width:358px" %)sed_metrology_001.bin 96 -|7.|(% style="width:214px" %)sed_modbus_rtd_send|(% style="width:676px" %)A service for sending real-time data to third-party devices using the Modbus TCP protocol|(% style="width:358px" %) 97 -|8.|(% style="width:214px" %)sed_modbus_sync|(% style="width:676px" %)A device time synchronization service using Modbus protocol (Modbus TCP and Modbus RTU over TCP)|(% style="width:358px" %) 98 -|9.|(% style="width:214px" %)sed_snmp_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the SNMP (v1, v2c, v3), ICMP protocols|(% style="width:358px" %) 99 -|10.|(% style="width:214px" %)sed_iec103_waveform|(% style="width:676px" %)A service for reading waveform files from devices using the IEC protocol-60870-5-103|(% style="width:358px" %)sed_metrology_393.bin 100 -|11.|(% style="width:214px" %)sed_iec104_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the IEC 60870-5-104 protocol|(% style="width:358px" %)sed_metrology_011.bin 101 -|12.|(% style="width:214px" %)sed_iec104_rtd_send|(% style="width:676px" %)A service for sending real-time data to third-party devices using the IEC 60870-5-104 protocol|(% style="width:358px" %)sed_metrology_012.bin 102 -|13.|(% style="width:214px" %)sed_opcda_rtd|(% style="width:676px" %)A service for receiving real-time data using the OPC DA protocol|(% style="width:358px" %) 103 -|14.|(% style="width:214px" %)sed_opcua_rtd|(% style="width:676px" %)A service for receiving real-time data using the OPC UA protocol|(% style="width:358px" %) 104 -|15.|(% style="width:214px" %)sed_opcua_arch|(% style="width:676px" %)A service for receiving archived data using the OPC UA protocol|(% style="width:358px" %)sed_metrology_402.bin 105 -|16.|(% style="width:214px" %)sed_opcua_server|(% style="width:676px" %)A service for transmitting data using the OPC UA protocol|(% style="width:358px" %) 106 -|17.|(% style="width:214px" %)sed_dnp3_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the DNP3 protocol|(% style="width:358px" %) 107 -| |(% style="width:214px" %)sed_ftp_waveform|(% style="width:676px" %)A service for receiving waveform files via FTP protocol|(% style="width:358px" %)sed_metrology_380.bin 108 -| |(% style="width:214px" %)sed_iec61107_rtd|(% style="width:676px" %)A service for obtaining real-time data from devices using the IEC 62056-21 protocol|(% style="width:358px" %)sed_metrology_61107.bin 109 -| |(% style="width:214px" %)sed_iec61850_arch|(% style="width:676px" %)A service for receiving archived data from devices using the IEC 61850 protocol|(% style="width:358px" %) 110 -| |(% style="width:214px" %)sed_iec61850_rtd|(% style="width:676px" %)A service for receiving operational data from devices using the IEC 61850 protocol|(% style="width:358px" %) 111 -|(% colspan="4" %)**Proprietary protocol data collection and transmission services** 112 -|((( 113 -1. 114 -)))|(% style="width:214px" %)sed_satec_arch|(% style="width:676px" %)A service for reading archived data (metering and event logs) from SATEC devices|(% style="width:358px" %)sed_metrology_7_8.bin 115 -|((( 116 -1. 117 -)))|(% style="width:214px" %)sed_satec_pq_journal|(% style="width:676px" %)A service for obtaining event logs for monitoring the power quality from Satec devices|(% style="width:358px" %)sed_metrology_106.bin 118 -|((( 119 -1. 120 -)))|(% style="width:214px" %)sed_satec_pq_report|(% style="width:676px" %)A service for receiving reports on the power quality control from Satec devices|(% style="width:358px" %)sed_metrology_106.bin 121 -|((( 122 -1. 123 -)))|(% style="width:214px" %)sed_satec_waveforms|(% style="width:676px" %)A service for proofreading waveforms from SATEC devices using Modbus TCP and RTU over TCP protocols|(% style="width:358px" %)sed_metrology_108_109.bin 124 -|((( 125 -1. 126 -)))|(% style="width:214px" %)sed_iec103_rtd|(% style="width:676px" %)A service for reading real-time data from TOR 200 terminals according to the IEC protocol-60870-5-103|(% style="width:358px" %)sed_metrology_391.bin 127 -|((( 128 -1. 129 -)))|(% style="width:214px" %)sed_sepam_waveform|(% style="width:676px" %)A service for proofreading waveforms and time synchronization using the Modbus RTU over TCP protocol from Sepam devices|(% style="width:358px" %)sed_metrology_298_299.bin 130 -|((( 131 -1. 132 -)))|(% style="width:214px" %)sed_rtu_over_tcp_logikamp_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the LogicaMP RTU over TCP protocol|(% style="width:358px" %)sed_metrology_121.bin 133 -|((( 134 -1. 135 -)))|(% style="width:214px" %)sed_rtu_over_tcp_logikamp_arch|(% style="width:676px" %)A service for reading archived data from devices using the LogicaMP RTU over TCP protocol|(% style="width:358px" %)sed_metrology_122.bin 136 -|((( 137 -1. 138 -)))|(% style="width:214px" %)sed_axis_video_journal|(% style="width:676px" %)An AXIS camera recording service|(% style="width:358px" %)sed_metrology_435.bin 139 -|((( 140 -1. 141 -)))|(% style="width:214px" %)sed_vzlyotmb_arch|(% style="width:676px" %)A service for reading archives and event logs of devices Vzlet TSRV-043, TSRV-027, IVK-TER|(% style="width:358px" %)sed_metrology_25_133.bin 142 -|((( 143 -1. 144 -)))|(% style="width:214px" %)sed_micom_waveforms|(% style="width:676px" %)A service for reading waveform files from Micom devices using Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_370.bin 145 -|((( 146 -1. 147 -)))|(% style="width:214px" %)sed_pulsar_arch|(% style="width:676px" %)A service for reading archives from Pulsar devices using the Modbus protocol|(% style="width:358px" %)sed_metrology_342.bin 148 -|((( 149 -1. 150 -)))|(% style="width:214px" %)sed_rtu_over_tcp_a1800_arch|(% style="width:676px" %)A service for receiving archived data from A1800 meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_232.bin 151 -|((( 152 -1. 153 -)))|(% style="width:214px" %)sed_rtu_over_tcp_a1800_rtd|(% style="width:676px" %)A service for receiving real-time data from A1800 meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_231.bin 154 -|((( 155 -1. 156 -)))|(% style="width:214px" %)sed_rtu_over_tcp_acron_arch|(% style="width:676px" %)A service for receiving archived data from Acron meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_142.bin 157 -|((( 158 -1. 159 -)))|(% style="width:214px" %)sed_rtu_over_tcp_acron_rtd|(% style="width:676px" %)A service for receiving real-time data from Acron meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_141.bin 160 -|((( 161 -1. 162 -)))|(% style="width:214px" %)sed_rtu_over_tcp_bmrz_waveform|(% style="width:676px" %)A service for reading waveform files from BMRZ terminals using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_110.bin 163 -|((( 164 -1. 165 -)))|(% style="width:214px" %)sed_rtu_over_tcp_bzp03_waveform|(% style="width:676px" %)A service for reading waveform files from BZP-03 terminals using Modbus RTU over TCP protocol|(% style="width:358px" %) 166 -|((( 167 -1. 168 -)))|(% style="width:214px" %)sed_rtu_over_tcp_kmp_rtd|(% style="width:676px" %)A service for polling Multitical 601 device using the KMP protocol|(% style="width:358px" %)sed_metrology_191.bin 169 -|((( 170 -1. 171 -)))|(% style="width:214px" %)sed_rtu_over_tcp_majac_arch|(% style="width:676px" %)A service for receiving archived data from devices using the Mayak protocol|(% style="width:358px" %)sed_metrology_152.bin 172 -|((( 173 -1. 174 -)))|(% style="width:214px" %)sed_rtu_over_tcp_mercury200_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the Mercury 200 protocol|(% style="width:358px" %)sed_metrology_251.bin 175 -|((( 176 -1. 177 -)))|(% style="width:214px" %)sed_rtu_over_tcp_mercury_arch|(% style="width:676px" %)A service for reading archives and event logs from Mercury-230 series devices using the Mercury-230 protocol|(% style="width:358px" %)sed_metrology_202.bin 178 -|((( 179 -1. 180 -)))|(% style="width:214px" %)sed_rtu_over_tcp_mercury_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the Mercury 230 protocol|(% style="width:358px" %)sed_metrology_201.bin 181 -|((( 182 -1. 183 -)))|(% style="width:214px" %)sed_rtu_over_tcp_photon_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the photon RTU over TCP protocol|(% style="width:358px" %)sed_metrology_221.bin 184 -|((( 185 -1. 186 -)))|(% style="width:214px" %)sed_rtu_over_tcp_ref542plus_waveform|(% style="width:676px" %)Proofreading of waveforms and time synchronization via Modbus RTU over TCP protocol from ABB REF 542plus devices|(% style="width:358px" %) 187 -|((( 188 -1. 189 -)))|(% style="width:214px" %)sed_rtu_over_tcp_set4tm_arch|(% style="width:676px" %)A service for polling SET-4TM, PSC meters’ archives|(% style="width:358px" %)sed_metrology_112.bin 190 -|((( 191 -1. 192 -)))|(% style="width:214px" %)sed_rtu_over_tcp_set4tm_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the SET-4TM rtu over tcp protocol|(% style="width:358px" %)sed_metrology_111.bin 193 -|((( 194 -1. 195 -)))|(% style="width:214px" %)sed_rtu_over_tcp_tem104_arch|(% style="width:676px" %)A service for receiving archived data from devices using the TEM104 protocol|(% style="width:358px" %)sed_metrology_162.bin 196 -|((( 197 -1. 198 -)))|(% style="width:214px" %)sed_rtu_over_tcp_tem104_rtd|(% style="width:676px" %)A service for receiving real-tume data from devices using the TEM104 protocol|(% style="width:358px" %)sed_metrology_161.bin 199 -|((( 200 -1. 201 -)))|(% style="width:214px" %)sed_rtu_over_tcp_vist_arch|(% style="width:676px" %)A service for receiving archived data from devices using the VIS.T protocol|(% style="width:358px" %)sed_metrology_172.bin 202 -|((( 203 -1. 204 -)))|(% style="width:214px" %)sed_rtu_over_tcp_vkt5_arch|(% style="width:676px" %)A service for receiving archived data from VKT-5 devices|(% style="width:358px" %)sed_metrology_312.bin 205 -|((( 206 -1. 207 -)))|(% style="width:214px" %)sed_rtu_over_tcp_vkt5_rtd|(% style="width:676px" %)A service for receiving real-time data from VKT-5 devices|(% style="width:358px" %)sed_metrology_311.bin 208 -|((( 209 -1. 210 -)))|(% style="width:214px" %)sed_vkt7_arch|(% style="width:676px" %)A service for receiving archived data from VKT-7 devices|(% style="width:358px" %) 211 -|((( 212 -1. 213 -)))|(% style="width:214px" %)sed_vkt7_rtd|(% style="width:676px" %)A service for receiving real-time data from VKT-7 devices|(% style="width:358px" %) 214 -|((( 215 -1. 216 -)))|(% style="width:214px" %)sed_rtu_over_tcp_vtd_arch|(% style="width:676px" %)A service for receiving archived data of VTD devices|(% style="width:358px" %)sed_metrology_182.bin 217 -|((( 218 -1. 219 -)))|(% style="width:214px" %)sed_rtu_over_tcp_vtd_rtd|(% style="width:676px" %)A service for receiving operational data from VTD devices|(% style="width:358px" %)sed_metrology_181.bin 220 -|((( 221 -1. 222 -)))|(% style="width:214px" %)sed_uvp_arch|(% style="width:676px" %)A service for poling Promavtomatika's archive for devices of the UVP series|(% style="width:358px" %)sed_metrology_352.bin 223 -|((( 224 -1. 225 -)))|(% style="width:214px" %)sed_ce_arch|(% style="width:676px" %)A service for receiving archived data from Energomera devices of the CE series according to the IEC61107 protocol|(% style="width:358px" %)sed_metrology_362.bin 226 -|((( 227 -1. 228 -)))|(% style="width:214px" %)sed_alpha_arch|(% style="width:676px" %)A service for receiving archived data from Alfa-3 devices manufactured by Alfamera|(% style="width:358px" %)sed_metrology_462_472.bin 229 -|((( 230 -1. 231 -)))|(% style="width:214px" %)sed_bug01_rtd|(% style="width:676px" %)A service for receiving archived data of BUG-01 devices|(% style="width:358px" %)sed_metrology_491.bin 232 -|((( 233 -1. 234 -)))|(% style="width:214px" %)sed_dymetic_arch|(% style="width:676px" %)A service for receiving archived data from Dimetik|(% style="width:358px" %)sed_metrology_552.bin 235 -|((( 236 -1. 237 -)))|(% style="width:214px" %)sed_irvis_arch|(% style="width:676px" %)A service for receiving archived data from devices using the Irvis protocol|(% style="width:358px" %)sed_metrology_442.bin 238 -|((( 239 -1. 240 -)))|(% style="width:214px" %)sed_karat_arch|(% style="width:676px" %)A service for receiving archived data from Karat devices|(% style="width:358px" %)sed_metrology_512.bin 241 -|((( 242 -1. 243 -)))|(% style="width:214px" %)sed_lis200_arch|(% style="width:676px" %)A service for receiving archived data from the EK-260 and EK-270 devices manufactured by Elster|(% style="width:358px" %)sed_metrology_452.bin 244 -|((( 245 -1. 246 -)))|(% style="width:214px" %)sed_rtu_over_tcp_sepam_waveform|(% style="width:676px" %)A service for reading waveform files from Sepam devices using Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_298.bin 247 -|(% colspan="4" %)**Data export and import services in SQL databases** 248 -|((( 249 -1. 250 -)))|(% style="width:214px" %)sed_sql_rtd|(% style="width:676px" %)A service for receiving tele-measurement data from MySQL|(% style="width:358px" %)sed_metrology_211.bin 251 -|((( 252 -1. 253 -)))|(% style="width:214px" %)sed_sql_arch|(% style="width:676px" %)A service for archived data retrieval from Microsoft SQL Server|(% style="width:358px" %) 254 -|((( 255 -1. 256 -)))|(% style="width:214px" %)sed_sql_arch_send|(% style="width:676px" %)A service for recording archived data in an external SQL database|(% style="width:358px" %) 257 -|(% colspan="4" %)**Data processing services** 258 -|((( 259 -1. 260 -)))|(% style="width:214px" %)sed_controller|(% style="width:676px" %)A service for telemetry reception and processing (writes to the InfluxDB database)|(% style="width:358px" %)sed_metrology_controller.bin 261 -|((( 262 -1. 263 -)))|(% style="width:214px" %)sed_events_calc|(% style="width:676px" %)A service for generating event based on the conditions specified in the configuration|(% style="width:358px" %) 264 -|((( 265 -1. 266 -)))|(% style="width:214px" %)sed_calc_arch|(% style="width:676px" %)A service for calculating metering channels|(% style="width:358px" %)((( 267 -sed_metrology_calc_arch.bin 268 - 269 -sed_metrology_formulas.bin 270 -))) 271 -|((( 272 -1. 273 -)))|(% style="width:214px" %)sed_calc_rtd|(% style="width:676px" %)A service for calculating pre-calculated tags|(% style="width:358px" %) 274 -|((( 275 -1. 276 -)))|(% style="width:214px" %)sed_round_arch|(% style="width:676px" %)A service for calculating metering channels with rounding|(% style="width:358px" %)sed_metrology_round_arch.bin 277 -|((( 278 -1. 279 -)))|(% style="width:214px" %)sed_energy_calc|(% style="width:676px" %)A service for server-level energy resource calculation|(% style="width:358px" %)sed_metrology_411_421.bin 280 -|((( 281 -1. 282 -)))|(% style="width:214px" %)sed_loadflow_calc|(% style="width:676px" %)A service for calculating modes based on an information model|(% style="width:358px" %) 283 -|((( 284 -1. 285 -)))|(% style="width:214px" %)sed_storage_writer|(% style="width:676px" %)A service for recording archived data (metering and event logs) in a data storage (InfluxDB and MongoDB)|(% style="width:358px" %) 286 -|(% colspan="4" %)**Web Part Services** 287 -|((( 288 -1. 289 -)))|(% style="width:214px" %)php5-cgi|(% style="width:676px" %)A Web Query Service|(% style="width:358px" %) 290 -|((( 291 -1. 292 -)))|(% style="width:214px" %)nginx|(% style="width:676px" %)A Web Server|(% style="width:358px" %) 293 -|((( 294 -1. 295 -)))|(% style="width:214px" %)sed_ui|(% style="width:676px" %)A service for processing requests for web resources (js, css, html files)|(% style="width:358px" %) 296 -|((( 297 -1. 298 -)))|(% style="width:214px" %)sed_rtd_analysis|(% style="width:676px" %)A service for analyzing real-time data|(% style="width:358px" %) 299 -|((( 300 -1. 301 -)))|(% style="width:214px" %)sed_auth|(% style="width:676px" %)A service for authenticating and authorizing users in the system and configuring access rights|(% style="width:358px" %) 302 -|((( 303 -1. 304 -)))|(% style="width:214px" %)sed_auth_privileges|(% style="width:676px" %)A User Privilege Management Service|(% style="width:358px" %) 305 -|((( 306 -1. 307 -)))|(% style="width:214px" %)sed_api_gateway|(% style="width:676px" %)A service for proxying of web requests to other services within the system|(% style="width:358px" %) 308 -|((( 309 -1. 310 -)))|(% style="width:214px" %)sed_dataset_configurator|(% style="width:676px" %)A service for working with datasets|(% style="width:358px" %) 311 -|((( 312 -1. 313 -)))|(% style="width:214px" %)sed_rtd|(% style="width:676px" %)A real-time data subscription service|(% style="width:358px" %) 314 -|((( 315 -1. 316 -)))|(% style="width:214px" %)sed_rtd_archive|(% style="width:676px" %)A service for generating archived data from real-time data|(% style="width:358px" %) 317 -|((( 318 -1. 319 -)))|(% style="width:214px" %)sed_system|(% style="width:676px" %)A service that provides a user interface with information about the system|(% style="width:358px" %) 320 -|((( 321 -1. 322 -)))|(% style="width:214px" %)sed_archive|(% style="width:676px" %)A service that provides user interfaces for analyzing electricity and energy accounting|(% style="width:358px" %) 323 -|((( 324 -1. 325 -)))|(% style="width:214px" %)sed_archive_integrity|(% style="width:676px" %)A service that provides user interfaces for analyzing the completeness of electricity and energy resources data|(% style="width:358px" %) 326 -|((( 327 -1. 328 -)))|(% style="width:214px" %)sed_pq_reports|(% style="width:676px" %)A service for working with power quality reports|(% style="width:358px" %) 329 -|((( 330 -1. 331 -)))|(% style="width:214px" %)sed_pq_journal|(% style="width:676px" %)A service for working with power quality logs|(% style="width:358px" %) 332 -|((( 333 -1. 334 -)))|(% style="width:214px" %)sed_ras_configurator|(% style="width:676px" %)A service for configuring emergency event loggers|(% style="width:358px" %) 335 -|((( 336 -1. 337 -)))|(% style="width:214px" %)sed_reports|(% style="width:676px" %)A service for generating and managing reports, and maintaining user interfaces for reports|(% style="width:358px" %) 338 -|((( 339 -1. 340 -)))|(% style="width:214px" %)sed_widgets|(% style="width:676px" %)A service for the user interfaces of drag'n'drop widgets|(% style="width:358px" %) 341 -|((( 342 -1. 343 -)))|(% style="width:214px" %)sed_menu|(% style="width:676px" %)A service for displaying and configuring CENTO system menu|(% style="width:358px" %) 344 -|((( 345 -1. 346 -)))|(% style="width:214px" %)sed_mnemonic_diagrams|(% style="width:676px" %)A service for the user interfaces of diagrams v2|(% style="width:358px" %) 347 -|((( 348 -1. 349 -)))|(% style="width:214px" %)sed_configuration|(% style="width:676px" %)A service for user interfaces for system configuration (alerts, mail servers, formulas, device trees)|(% style="width:358px" %) 350 -|((( 351 -1. 352 -)))|(% style="width:214px" %)sed_devices_configurator|(% style="width:676px" %)A service for editing device configurations, tags, and channels|(% style="width:358px" %) 353 -|((( 354 -1. 355 -)))|(% style="width:214px" %)sed_common_event_journal|(% style="width:676px" %)A service for user interfaces for generalized configurable event logs|(% style="width:358px" %) 356 -|((( 357 -1. 358 -)))|(% style="width:214px" %)sed_device_event_journal|(% style="width:676px" %)A Device Log Service|(% style="width:358px" %) 359 -|((( 360 -1. 361 -)))|(% style="width:214px" %)sed_operative_journal|(% style="width:676px" %)A service for the user interface of the real-time event log|(% style="width:358px" %) 362 -|((( 363 -1. 364 -)))|(% style="width:214px" %)sed_video_journal|(% style="width:676px" %)A Video Camera Log Service|(% style="width:358px" %) 365 -|((( 366 -1. 367 -)))|(% style="width:214px" %)sed_marking|(% style="width:676px" %)A Dispatch Tag Management Service|(% style="width:358px" %) 368 -|((( 369 -1. 370 -)))|(% style="width:214px" %)sed_sounds|(% style="width:676px" %)A service for the user interface for sound alerts management|(% style="width:358px" %) 371 -|((( 372 -1. 373 -)))|(% style="width:214px" %)sed_video_stream|(% style="width:676px" %)A service for streaming video from cameras registered in the information model|(% style="width:358px" %) 374 -|(% colspan="4" %)**System services** 375 -|((( 376 -1. 377 -)))|(% style="width:214px" %)nats|(% style="width:676px" %)A message broker and a service registry (service registry/service discovery)|(% style="width:358px" %) 378 -|((( 379 -1. 380 -)))|(% style="width:214px" %)influxdb|(% style="width:676px" %)A time series database|(% style="width:358px" %) 381 -|((( 382 -1. 383 -)))|(% style="width:214px" %)mongod|(% style="width:676px" %)A database of configuration and structured data (event logs, requests)|(% style="width:358px" %) 384 -|((( 385 -1. 386 -)))|(% style="width:214px" %)sed_signals|(% style="width:676px" %)A signal reception and transmission service inside the system (remote control, configuration update, manual polling, parameter recalculation)|(% style="width:358px" %) 387 -|((( 388 -1. 389 -)))|(% style="width:214px" %)sed_debug|(% style="width:676px" %)A service for providing access to debugging information of CENTO services|(% style="width:358px" %) 390 -|((( 391 -1. 392 -)))|(% style="width:214px" %)sed_graphql|(% style="width:676px" %)A subscription service for device statuses|(% style="width:358px" %) 393 -|((( 394 -1. 395 -)))|(% style="width:214px" %)sed_energy_calc_configuration|(% style="width:676px" %)A service for creating, changing, and deleting energy resource calculation configurations at the server level|(% style="width:358px" %) 396 -|((( 397 -1. 398 -)))|(% style="width:214px" %)sed_backup|(% style="width:676px" %)A service for backing up data according to the cron rule.|(% style="width:358px" %) 399 -|((( 400 -1. 401 -)))|(% style="width:214px" %)sed_channels|(% style="width:676px" %)A channel subscription service|(% style="width:358px" %) 402 -|((( 403 -1. 404 -)))|(% style="width:214px" %)sed_channels_data|(% style="width:676px" %)A subscription service for protocol statuses and the latest channel data|(% style="width:358px" %) 405 -|((( 406 -1. 407 -)))|(% style="width:214px" %)sed_emission_archive|(% style="width:676px" %)A service for providing emissions metering data|(% style="width:358px" %) 408 -|((( 409 -1. 410 -)))|(% style="width:214px" %)sed_profile_archive|(% style="width:676px" %)A service for providing metering data from InfluxDB via gRPC.|(% style="width:358px" %) 411 -|((( 412 -1. 413 -)))|(% style="width:214px" %)sed_web_storage|(% style="width:676px" %)A service for accessing archived metering data|(% style="width:358px" %) 414 -|((( 415 -1. 416 -)))|(% style="width:214px" %)sed_watchdog|(% style="width:676px" %)A service for managing the launch of CENTO services|(% style="width:358px" %) 417 -|((( 418 -1. 419 -)))|(% style="width:214px" %)sed_scheduler|(% style="width:676px" %)A service for launching scheduled tasks|(% style="width:358px" %) 420 -|((( 421 -1. 422 -)))|(% style="width:214px" %)sed_license|(% style="width:676px" %)A licensing service|(% style="width:358px" %) 423 -|((( 424 -1. 425 -)))|(% style="width:214px" %)sed_monitor|(% style="width:676px" %)A service for monitoring the operation of the system's services and applications|(% style="width:358px" %) 426 -|((( 427 -1. 428 -)))|(% style="width:214px" %)sed_telecontrol|(% style="width:676px" %)A remote control service|(% style="width:358px" %) 429 -|((( 430 -1. 431 -)))|(% style="width:214px" %)sed_notificator|(% style="width:676px" %)A service for notifying users about events by e-mail|(% style="width:358px" %) 432 -|((( 433 -1. 434 -)))|(% style="width:214px" %)sed_waveforms_journal|(% style="width:676px" %)A waveform Log Service|(% style="width:358px" %) 435 -|((( 436 -1. 437 -)))|(% style="width:214px" %)sed_storage_configurator|(% style="width:676px" %)An InfluxDB Database Configuration Service|(% style="width:358px" %) 438 -|((( 439 -1. 440 -)))|(% style="width:214px" %)sed_system_configuration|(% style="width:676px" %)A CENTO System Configuration Editing Service|(% style="width:358px" %) 441 -|((( 442 -1. 443 -)))|(% style="width:214px" %)sed_user_settings|(% style="width:676px" %)A User Settings Configuration Service|(% style="width:358px" %) 444 -|((( 445 -1. 446 -)))|(% style="width:214px" %)sed_system_event_journal|(% style="width:676px" %)A service for registration and provision of system events (business logic and administration)|(% style="width:358px" %) 447 -|((( 448 -1. 449 -)))|(% style="width:214px" %)sed_tech_event_journal|(% style="width:676px" %)A service for processing and managing technological events|(% style="width:358px" %) 450 -|((( 451 -1. 452 -)))|(% style="width:214px" %)sed_information_model|(% style="width:676px" %)A System Information Model Management Service|(% style="width:358px" %) 453 -|((( 454 -1. 455 -)))|(% style="width:214px" %)sed_events_configurator|(% style="width:676px" %)A System Event Configuration Service|(% style="width:358px" %) 456 -|((( 457 -1. 458 -)))|(% style="width:214px" %)sed_information_model_editor|(% style="width:676px" %)A service for editing the information model|(% style="width:358px" %) 459 -|(% colspan="4" %)**Server Backup Services** 460 -|((( 461 -1. 462 -)))|(% style="width:214px" %)sed_coordinator|(% style="width:676px" %)A service for selecting the cluster's host server using the Bully leader election algorithm|(% style="width:358px" %) 463 -|((( 464 -1. 465 -)))|(% style="width:214px" %)sed_reserve|(% style="width:676px" %)A service for displaying a list of backup servers|(% style="width:358px" %) 466 -|((( 467 -1. 468 -)))|(% style="width:214px" %)sed_replicator|(% style="width:676px" %)A log replication service between cluster servers|(% style="width:358px" %) 469 -|((( 470 -1. 471 -)))|(% style="width:214px" %)sed_influx_replicator|(% style="width:676px" %)A data replication service (archives and telemetry) between cluster servers|(% style="width:358px" %) 472 -|((( 473 -1. 474 -)))|(% style="width:214px" %)sed_events_replicator|(% style="width:676px" %)An event replication service between cluster servers|(% style="width:358px" %) 475 -|((( 476 -1. 477 -)))|(% style="width:214px" %)sed_fs_synch|(% style="width:676px" %)A data replication service (gob files, reports, waveforms) between cluster servers|(% style="width:358px" %) 77 +