Last modified by Iaroslav Platonov on 2026/06/08 10:08

From version 6.2
edited by Lana
on 2025/12/03 21:51
Change comment: There is no comment for this version
To version 6.8
edited by Lana
on 2025/12/03 21:58
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -74,4 +74,292 @@
74 74  
75 75  Table 1 – CENTO software components
76 76  
77 -
77 +|(% style="text-align:center" %)**№**|(% style="text-align:center; width:214px" %)**Service Name**|(% style="text-align:center; width:676px" %)**Function**|(% style="text-align:center; width:358px" %)**Metrologically significant part**
78 +|(% colspan="4" style="text-align:center" %)**Data collection and transmission services**
79 +|(((
80 +~1.
81 +)))|(% style="width:214px" %)sed_bus_dispatcher|(% style="width:676px" %)Sequential Device Polling Management Service|(% style="width:358px" %)
82 +|(((
83 +2.
84 +)))|(% style="width:214px" %)sed_xml_reader|(% style="width:676px" %)Service for processing received XML files 80020|(% style="width:358px" %)
85 +|(((
86 +3.
87 +)))|(% style="width:214px" %)sed_xml_send|(% style="width:676px" %)XML file transfer Service 80020|(% style="width:358px" %)
88 +|(((
89 +4.
90 +)))|(% style="width:214px" %)sed_archive_webapi|(% style="width:676px" %)Implementation of the web API for transmitting archived data according to the CENTO documentation|(% style="width:358px" %)
91 +|(((
92 +5.
93 +)))|(% style="width:214px" %)sed_s2s_configuration|(% style="width:676px" %)Configuration transmission service between CENTO servers|(% style="width:358px" %)
94 +|(% colspan="4" style="text-align:center" %)**Data collection and transmission services using standard protocols**
95 +|6.|(% style="width:214px" %)sed_modbus_rtd|(% style="width:676px" %)A service for reading real-time data from devices using Modbus protocol (Modbus TCP and Modbus RTU over TCP)|(% style="width:358px" %)sed_metrology_001.bin
96 +|7.|(% style="width:214px" %)sed_modbus_rtd_send|(% style="width:676px" %)A service for sending real-time data to third-party devices using the Modbus TCP protocol|(% style="width:358px" %)
97 +|8.|(% style="width:214px" %)sed_modbus_sync|(% style="width:676px" %)A device time synchronization service using Modbus protocol (Modbus TCP and Modbus RTU over TCP)|(% style="width:358px" %)
98 +|9.|(% style="width:214px" %)sed_snmp_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the SNMP (v1, v2c, v3), ICMP protocols|(% style="width:358px" %)
99 +|10.|(% style="width:214px" %)sed_iec103_waveform|(% style="width:676px" %)A service for reading waveform files from devices using the IEC protocol-60870-5-103|(% style="width:358px" %)sed_metrology_393.bin
100 +|11.|(% style="width:214px" %)sed_iec104_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the IEC 60870-5-104 protocol|(% style="width:358px" %)sed_metrology_011.bin
101 +|12.|(% style="width:214px" %)sed_iec104_rtd_send|(% style="width:676px" %)A service for sending real-time data to third-party devices using the IEC 60870-5-104 protocol|(% style="width:358px" %)sed_metrology_012.bin
102 +|13.|(% style="width:214px" %)sed_opcda_rtd|(% style="width:676px" %)A service for receiving real-time data using the OPC DA protocol|(% style="width:358px" %)
103 +|14.|(% style="width:214px" %)sed_opcua_rtd|(% style="width:676px" %)A service for receiving real-time data using the OPC UA protocol|(% style="width:358px" %)
104 +|15.|(% style="width:214px" %)sed_opcua_arch|(% style="width:676px" %)A service for receiving archived data using the OPC UA protocol|(% style="width:358px" %)sed_metrology_402.bin
105 +|16.|(% style="width:214px" %)sed_opcua_server|(% style="width:676px" %)A service for transmitting data using the OPC UA protocol|(% style="width:358px" %)
106 +|17.|(% style="width:214px" %)sed_dnp3_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the DNP3 protocol|(% style="width:358px" %)
107 +|18.|(% style="width:214px" %)sed_ftp_waveform|(% style="width:676px" %)A service for receiving waveform files via FTP protocol|(% style="width:358px" %)sed_metrology_380.bin
108 +|19.|(% style="width:214px" %)sed_iec61107_rtd|(% style="width:676px" %)A service for obtaining real-time data from devices using the IEC 62056-21 protocol|(% style="width:358px" %)sed_metrology_61107.bin
109 +|20.|(% style="width:214px" %)sed_iec61850_arch|(% style="width:676px" %)A service for receiving archived data from devices using the IEC 61850 protocol|(% style="width:358px" %)
110 +|21.|(% style="width:214px" %)sed_iec61850_rtd|(% style="width:676px" %)A service for receiving operational data from devices using the IEC 61850 protocol|(% style="width:358px" %)
111 +|(% colspan="4" style="text-align:center" %)**Proprietary protocol data collection and transmission services**
112 +|22.|(% style="width:214px" %)sed_satec_arch|(% style="width:676px" %)A service for reading archived data (metering and event logs) from SATEC devices|(% style="width:358px" %)sed_metrology_7_8.bin
113 +|23.|(% style="width:214px" %)sed_satec_pq_journal|(% style="width:676px" %)A service for obtaining event logs for monitoring the power quality from Satec devices|(% style="width:358px" %)sed_metrology_106.bin
114 +|24.|(% style="width:214px" %)sed_satec_pq_report|(% style="width:676px" %)A service for receiving reports on the power quality control from Satec devices|(% style="width:358px" %)sed_metrology_106.bin
115 +|25.|(% style="width:214px" %)sed_satec_waveforms|(% style="width:676px" %)A service for proofreading waveforms from SATEC devices using Modbus TCP and RTU over TCP protocols|(% style="width:358px" %)sed_metrology_108_109.bin
116 +|26.|(% style="width:214px" %)sed_iec103_rtd|(% style="width:676px" %)A service for reading real-time data from TOR 200 terminals according to the IEC protocol-60870-5-103|(% style="width:358px" %)sed_metrology_391.bin
117 +|27.|(% style="width:214px" %)sed_sepam_waveform|(% style="width:676px" %)A service for proofreading waveforms and time synchronization using the Modbus RTU over TCP protocol from Sepam devices|(% style="width:358px" %)sed_metrology_298_299.bin
118 +|28.|(% style="width:214px" %)sed_rtu_over_tcp_logikamp_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the LogicaMP RTU over TCP protocol|(% style="width:358px" %)sed_metrology_121.bin
119 +|29.|(% style="width:214px" %)sed_rtu_over_tcp_logikamp_arch|(% style="width:676px" %)A service for reading archived data from devices using the LogicaMP RTU over TCP protocol|(% style="width:358px" %)sed_metrology_122.bin
120 +|30.|(% style="width:214px" %)sed_axis_video_journal|(% style="width:676px" %)An AXIS camera recording service|(% style="width:358px" %)sed_metrology_435.bin
121 +|31.|(% style="width:214px" %)sed_vzlyotmb_arch|(% style="width:676px" %)A service for reading archives and event logs of devices Vzlet TSRV-043, TSRV-027, IVK-TER|(% style="width:358px" %)sed_metrology_25_133.bin
122 +|32.|(% style="width:214px" %)sed_micom_waveforms|(% style="width:676px" %)A service for reading waveform files from Micom devices using Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_370.bin
123 +|33.|(% style="width:214px" %)sed_pulsar_arch|(% style="width:676px" %)A service for reading archives from Pulsar devices using the Modbus protocol|(% style="width:358px" %)sed_metrology_342.bin
124 +|34.|(% style="width:214px" %)sed_rtu_over_tcp_a1800_arch|(% style="width:676px" %)A service for receiving archived data from A1800 meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_232.bin
125 +|35.|(% style="width:214px" %)sed_rtu_over_tcp_a1800_rtd|(% style="width:676px" %)A service for receiving real-time data from A1800 meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_231.bin
126 +|36.|(% style="width:214px" %)sed_rtu_over_tcp_acron_arch|(% style="width:676px" %)A service for receiving archived data from Acron meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_142.bin
127 +|37.|(% style="width:214px" %)sed_rtu_over_tcp_acron_rtd|(% style="width:676px" %)A service for receiving real-time data from Acron meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_141.bin
128 +|38.|(% style="width:214px" %)sed_rtu_over_tcp_bmrz_waveform|(% style="width:676px" %)A service for reading waveform files from BMRZ terminals using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_110.bin
129 +|39.|(% style="width:214px" %)sed_rtu_over_tcp_bzp03_waveform|(% style="width:676px" %)A service for reading waveform files from BZP-03 terminals using Modbus RTU over TCP protocol|(% style="width:358px" %)
130 +|40.|(% style="width:214px" %)sed_rtu_over_tcp_kmp_rtd|(% style="width:676px" %)A service for polling Multitical 601 device using the KMP protocol|(% style="width:358px" %)sed_metrology_191.bin
131 +|41.|(% style="width:214px" %)sed_rtu_over_tcp_majac_arch|(% style="width:676px" %)A service for receiving archived data from devices using the Mayak protocol|(% style="width:358px" %)sed_metrology_152.bin
132 +|42.|(% style="width:214px" %)sed_rtu_over_tcp_mercury200_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the Mercury 200 protocol|(% style="width:358px" %)sed_metrology_251.bin
133 +|43.|(% style="width:214px" %)sed_rtu_over_tcp_mercury_arch|(% style="width:676px" %)A service for reading archives and event logs from Mercury-230 series devices using the Mercury-230 protocol|(% style="width:358px" %)sed_metrology_202.bin
134 +|44.|(% style="width:214px" %)sed_rtu_over_tcp_mercury_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the Mercury 230 protocol|(% style="width:358px" %)sed_metrology_201.bin
135 +|45.|(% style="width:214px" %)sed_rtu_over_tcp_photon_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the photon RTU over TCP protocol|(% style="width:358px" %)sed_metrology_221.bin
136 +|46.|(% style="width:214px" %)sed_rtu_over_tcp_ref542plus_waveform|(% style="width:676px" %)Proofreading of waveforms and time synchronization via Modbus RTU over TCP protocol from ABB REF 542plus devices|(% style="width:358px" %)
137 +|47.|(% style="width:214px" %)sed_rtu_over_tcp_set4tm_arch|(% style="width:676px" %)A service for polling SET-4TM, PSC meters’ archives|(% style="width:358px" %)sed_metrology_112.bin
138 +|48.|(% style="width:214px" %)sed_rtu_over_tcp_set4tm_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the SET-4TM rtu over tcp protocol|(% style="width:358px" %)sed_metrology_111.bin
139 +|49.|(% style="width:214px" %)sed_rtu_over_tcp_tem104_arch|(% style="width:676px" %)A service for receiving archived data from devices using the TEM104 protocol|(% style="width:358px" %)sed_metrology_162.bin
140 +|50.|(% style="width:214px" %)sed_rtu_over_tcp_tem104_rtd|(% style="width:676px" %)A service for receiving real-tume data from devices using the TEM104 protocol|(% style="width:358px" %)sed_metrology_161.bin
141 +|51.|(% style="width:214px" %)sed_rtu_over_tcp_vist_arch|(% style="width:676px" %)A service for receiving archived data from devices using the VIS.T protocol|(% style="width:358px" %)sed_metrology_172.bin
142 +|52.|(% style="width:214px" %)sed_rtu_over_tcp_vkt5_arch|(% style="width:676px" %)A service for receiving archived data from VKT-5 devices|(% style="width:358px" %)sed_metrology_312.bin
143 +|53.|(% style="width:214px" %)sed_rtu_over_tcp_vkt5_rtd|(% style="width:676px" %)A service for receiving real-time data from VKT-5 devices|(% style="width:358px" %)sed_metrology_311.bin
144 +|54.|(% style="width:214px" %)sed_vkt7_arch|(% style="width:676px" %)A service for receiving archived data from VKT-7 devices|(% style="width:358px" %)
145 +|55.|(% style="width:214px" %)sed_vkt7_rtd|(% style="width:676px" %)A service for receiving real-time data from VKT-7 devices|(% style="width:358px" %)
146 +|56.|(% style="width:214px" %)sed_rtu_over_tcp_vtd_arch|(% style="width:676px" %)A service for receiving archived data of VTD devices|(% style="width:358px" %)sed_metrology_182.bin
147 +|57.|(% style="width:214px" %)sed_rtu_over_tcp_vtd_rtd|(% style="width:676px" %)A service for receiving operational data from VTD devices|(% style="width:358px" %)sed_metrology_181.bin
148 +|58.|(% style="width:214px" %)sed_uvp_arch|(% style="width:676px" %)A service for poling Promavtomatika's archive for devices of the UVP series|(% style="width:358px" %)sed_metrology_352.bin
149 +|59.|(% style="width:214px" %)sed_ce_arch|(% style="width:676px" %)A service for receiving archived data from Energomera devices of the CE series according to the IEC61107 protocol|(% style="width:358px" %)sed_metrology_362.bin
150 +|60.|(% style="width:214px" %)sed_alpha_arch|(% style="width:676px" %)A service for receiving archived data from Alfa-3 devices manufactured by Alfamera|(% style="width:358px" %)sed_metrology_462_472.bin
151 +|61.|(% style="width:214px" %)sed_bug01_rtd|(% style="width:676px" %)A service for receiving archived data of BUG-01 devices|(% style="width:358px" %)sed_metrology_491.bin
152 +|62.|(% style="width:214px" %)sed_dymetic_arch|(% style="width:676px" %)A service for receiving archived data from Dimetik|(% style="width:358px" %)sed_metrology_552.bin
153 +|63.|(% style="width:214px" %)sed_irvis_arch|(% style="width:676px" %)A service for receiving archived data from devices using the Irvis protocol|(% style="width:358px" %)sed_metrology_442.bin
154 +|64.|(% style="width:214px" %)sed_karat_arch|(% style="width:676px" %)A service for receiving archived data from Karat devices|(% style="width:358px" %)sed_metrology_512.bin
155 +|65.|(% style="width:214px" %)sed_lis200_arch|(% style="width:676px" %)A service for receiving archived data from the EK-260 and EK-270 devices manufactured by Elster|(% style="width:358px" %)sed_metrology_452.bin
156 +|66.|(% style="width:214px" %)sed_rtu_over_tcp_sepam_waveform|(% style="width:676px" %)A service for reading waveform files from Sepam devices using Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_298.bin
157 +|(% colspan="4" style="text-align:center" %)**Data export and import services in SQL databases**
158 +|67.|(% style="width:214px" %)sed_sql_rtd|(% style="width:676px" %)A service for receiving tele-measurement data from MySQL|(% style="width:358px" %)sed_metrology_211.bin
159 +|68.|(% style="width:214px" %)sed_sql_arch|(% style="width:676px" %)A service for archived data retrieval from Microsoft SQL Server|(% style="width:358px" %)
160 +|69.|(% style="width:214px" %)sed_sql_arch_send|(% style="width:676px" %)A service for recording archived data in an external SQL database|(% style="width:358px" %)
161 +|(% colspan="4" style="text-align:center" %)**Data processing services**
162 +| |(% style="width:214px" %)sed_controller|(% style="width:676px" %)A service for telemetry reception and processing (writes to the InfluxDB database)|(% style="width:358px" %)sed_metrology_controller.bin
163 +| |(% style="width:214px" %)sed_events_calc|(% style="width:676px" %)A service for generating event based on the conditions specified in the configuration|(% style="width:358px" %)
164 +| |(% style="width:214px" %)sed_calc_arch|(% style="width:676px" %)A service for calculating metering channels|(% style="width:358px" %)(((
165 +sed_metrology_calc_arch.bin
166 +
167 +sed_metrology_formulas.bin
168 +)))
169 +| |(% style="width:214px" %)sed_calc_rtd|(% style="width:676px" %)A service for calculating pre-calculated tags|(% style="width:358px" %)
170 +| |(% style="width:214px" %)sed_round_arch|(% style="width:676px" %)A service for calculating metering channels with rounding|(% style="width:358px" %)sed_metrology_round_arch.bin
171 +| |(% style="width:214px" %)sed_energy_calc|(% style="width:676px" %)A service for server-level energy resource calculation|(% style="width:358px" %)sed_metrology_411_421.bin
172 +| |(% style="width:214px" %)sed_loadflow_calc|(% style="width:676px" %)A service for calculating modes based on an information model|(% style="width:358px" %)
173 +| |(% style="width:214px" %)sed_storage_writer|(% style="width:676px" %)A service for recording archived data (metering and event logs) in a data storage (InfluxDB and MongoDB)|(% style="width:358px" %)
174 +|(% colspan="4" style="text-align:center" %)**Web Part Services**
175 +|(((
176 +1.
177 +)))|(% style="width:214px" %)php5-cgi|(% style="width:676px" %)A Web Query Service|(% style="width:358px" %)
178 +|(((
179 +1.
180 +)))|(% style="width:214px" %)nginx|(% style="width:676px" %)A Web Server|(% style="width:358px" %)
181 +|(((
182 +1.
183 +)))|(% style="width:214px" %)sed_ui|(% style="width:676px" %)A service for processing requests for web resources (js, css, html files)|(% style="width:358px" %)
184 +|(((
185 +1.
186 +)))|(% style="width:214px" %)sed_rtd_analysis|(% style="width:676px" %)A service for analyzing real-time data|(% style="width:358px" %)
187 +|(((
188 +1.
189 +)))|(% style="width:214px" %)sed_auth|(% style="width:676px" %)A service for authenticating and authorizing users in the system and configuring access rights|(% style="width:358px" %)
190 +|(((
191 +1.
192 +)))|(% style="width:214px" %)sed_auth_privileges|(% style="width:676px" %)A User Privilege Management Service|(% style="width:358px" %)
193 +|(((
194 +1.
195 +)))|(% style="width:214px" %)sed_api_gateway|(% style="width:676px" %)A service for proxying of web requests to other services within the system|(% style="width:358px" %)
196 +|(((
197 +1.
198 +)))|(% style="width:214px" %)sed_dataset_configurator|(% style="width:676px" %)A service for working with datasets|(% style="width:358px" %)
199 +|(((
200 +1.
201 +)))|(% style="width:214px" %)sed_rtd|(% style="width:676px" %)A real-time data subscription service|(% style="width:358px" %)
202 +|(((
203 +1.
204 +)))|(% style="width:214px" %)sed_rtd_archive|(% style="width:676px" %)A service for generating archived data from real-time data|(% style="width:358px" %)
205 +|(((
206 +1.
207 +)))|(% style="width:214px" %)sed_system|(% style="width:676px" %)A service that provides a user interface with information about the system|(% style="width:358px" %)
208 +|(((
209 +1.
210 +)))|(% style="width:214px" %)sed_archive|(% style="width:676px" %)A service that provides user interfaces for analyzing electricity and energy accounting|(% style="width:358px" %)
211 +|(((
212 +1.
213 +)))|(% style="width:214px" %)sed_archive_integrity|(% style="width:676px" %)A service that provides user interfaces for analyzing the completeness of electricity and energy resources data|(% style="width:358px" %)
214 +|(((
215 +1.
216 +)))|(% style="width:214px" %)sed_pq_reports|(% style="width:676px" %)A service for working with power quality reports|(% style="width:358px" %)
217 +|(((
218 +1.
219 +)))|(% style="width:214px" %)sed_pq_journal|(% style="width:676px" %)A service for working with power quality logs|(% style="width:358px" %)
220 +|(((
221 +1.
222 +)))|(% style="width:214px" %)sed_ras_configurator|(% style="width:676px" %)A service for configuring emergency event loggers|(% style="width:358px" %)
223 +|(((
224 +1.
225 +)))|(% style="width:214px" %)sed_reports|(% style="width:676px" %)A service for generating and managing reports, and maintaining user interfaces for reports|(% style="width:358px" %)
226 +|(((
227 +1.
228 +)))|(% style="width:214px" %)sed_widgets|(% style="width:676px" %)A service for the user interfaces of drag'n'drop widgets|(% style="width:358px" %)
229 +|(((
230 +1.
231 +)))|(% style="width:214px" %)sed_menu|(% style="width:676px" %)A service for displaying and configuring CENTO system menu|(% style="width:358px" %)
232 +|(((
233 +1.
234 +)))|(% style="width:214px" %)sed_mnemonic_diagrams|(% style="width:676px" %)A service for the user interfaces of diagrams v2|(% style="width:358px" %)
235 +|(((
236 +1.
237 +)))|(% style="width:214px" %)sed_configuration|(% style="width:676px" %)A service for user interfaces for system configuration (alerts, mail servers, formulas, device trees)|(% style="width:358px" %)
238 +|(((
239 +1.
240 +)))|(% style="width:214px" %)sed_devices_configurator|(% style="width:676px" %)A service for editing device configurations, tags, and channels|(% style="width:358px" %)
241 +|(((
242 +1.
243 +)))|(% style="width:214px" %)sed_common_event_journal|(% style="width:676px" %)A service for user interfaces for generalized configurable event logs|(% style="width:358px" %)
244 +|(((
245 +1.
246 +)))|(% style="width:214px" %)sed_device_event_journal|(% style="width:676px" %)A Device Log Service|(% style="width:358px" %)
247 +|(((
248 +1.
249 +)))|(% style="width:214px" %)sed_operative_journal|(% style="width:676px" %)A service for the user interface of the real-time event log|(% style="width:358px" %)
250 +|(((
251 +1.
252 +)))|(% style="width:214px" %)sed_video_journal|(% style="width:676px" %)A Video Camera Log Service|(% style="width:358px" %)
253 +|(((
254 +1.
255 +)))|(% style="width:214px" %)sed_marking|(% style="width:676px" %)A Dispatch Tag Management Service|(% style="width:358px" %)
256 +|(((
257 +1.
258 +)))|(% style="width:214px" %)sed_sounds|(% style="width:676px" %)A service for the user interface for sound alerts management|(% style="width:358px" %)
259 +|(((
260 +1.
261 +)))|(% style="width:214px" %)sed_video_stream|(% style="width:676px" %)A service for streaming video from cameras registered in the information model|(% style="width:358px" %)
262 +|(% colspan="4" %)**System services**
263 +|(((
264 +1.
265 +)))|(% style="width:214px" %)nats|(% style="width:676px" %)A message broker and a service registry (service registry/service discovery)|(% style="width:358px" %)
266 +|(((
267 +1.
268 +)))|(% style="width:214px" %)influxdb|(% style="width:676px" %)A time series database|(% style="width:358px" %)
269 +|(((
270 +1.
271 +)))|(% style="width:214px" %)mongod|(% style="width:676px" %)A database of configuration and structured data (event logs, requests)|(% style="width:358px" %)
272 +|(((
273 +1.
274 +)))|(% style="width:214px" %)sed_signals|(% style="width:676px" %)A signal reception and transmission service inside the system (remote control, configuration update, manual polling, parameter recalculation)|(% style="width:358px" %)
275 +|(((
276 +1.
277 +)))|(% style="width:214px" %)sed_debug|(% style="width:676px" %)A service for providing access to debugging information of CENTO services|(% style="width:358px" %)
278 +|(((
279 +1.
280 +)))|(% style="width:214px" %)sed_graphql|(% style="width:676px" %)A subscription service for device statuses|(% style="width:358px" %)
281 +|(((
282 +1.
283 +)))|(% style="width:214px" %)sed_energy_calc_configuration|(% style="width:676px" %)A service for creating, changing, and deleting energy resource calculation configurations at the server level|(% style="width:358px" %)
284 +|(((
285 +1.
286 +)))|(% style="width:214px" %)sed_backup|(% style="width:676px" %)A service for backing up data according to the cron rule.|(% style="width:358px" %)
287 +|(((
288 +1.
289 +)))|(% style="width:214px" %)sed_channels|(% style="width:676px" %)A channel subscription service|(% style="width:358px" %)
290 +|(((
291 +1.
292 +)))|(% style="width:214px" %)sed_channels_data|(% style="width:676px" %)A subscription service for protocol statuses and the latest channel data|(% style="width:358px" %)
293 +|(((
294 +1.
295 +)))|(% style="width:214px" %)sed_emission_archive|(% style="width:676px" %)A service for providing emissions metering data|(% style="width:358px" %)
296 +|(((
297 +1.
298 +)))|(% style="width:214px" %)sed_profile_archive|(% style="width:676px" %)A service for providing metering data from InfluxDB via gRPC.|(% style="width:358px" %)
299 +|(((
300 +1.
301 +)))|(% style="width:214px" %)sed_web_storage|(% style="width:676px" %)A service for accessing archived metering data|(% style="width:358px" %)
302 +|(((
303 +1.
304 +)))|(% style="width:214px" %)sed_watchdog|(% style="width:676px" %)A service for managing the launch of CENTO services|(% style="width:358px" %)
305 +|(((
306 +1.
307 +)))|(% style="width:214px" %)sed_scheduler|(% style="width:676px" %)A service for launching scheduled tasks|(% style="width:358px" %)
308 +|(((
309 +1.
310 +)))|(% style="width:214px" %)sed_license|(% style="width:676px" %)A licensing service|(% style="width:358px" %)
311 +|(((
312 +1.
313 +)))|(% style="width:214px" %)sed_monitor|(% style="width:676px" %)A service for monitoring the operation of the system's services and applications|(% style="width:358px" %)
314 +|(((
315 +1.
316 +)))|(% style="width:214px" %)sed_telecontrol|(% style="width:676px" %)A remote control service|(% style="width:358px" %)
317 +|(((
318 +1.
319 +)))|(% style="width:214px" %)sed_notificator|(% style="width:676px" %)A service for notifying users about events by e-mail|(% style="width:358px" %)
320 +|(((
321 +1.
322 +)))|(% style="width:214px" %)sed_waveforms_journal|(% style="width:676px" %)A waveform Log Service|(% style="width:358px" %)
323 +|(((
324 +1.
325 +)))|(% style="width:214px" %)sed_storage_configurator|(% style="width:676px" %)An InfluxDB Database Configuration Service|(% style="width:358px" %)
326 +|(((
327 +1.
328 +)))|(% style="width:214px" %)sed_system_configuration|(% style="width:676px" %)A CENTO System Configuration Editing Service|(% style="width:358px" %)
329 +|(((
330 +1.
331 +)))|(% style="width:214px" %)sed_user_settings|(% style="width:676px" %)A User Settings Configuration Service|(% style="width:358px" %)
332 +|(((
333 +1.
334 +)))|(% style="width:214px" %)sed_system_event_journal|(% style="width:676px" %)A service for registration and provision of system events (business logic and administration)|(% style="width:358px" %)
335 +|(((
336 +1.
337 +)))|(% style="width:214px" %)sed_tech_event_journal|(% style="width:676px" %)A service for processing and managing technological events|(% style="width:358px" %)
338 +|(((
339 +1.
340 +)))|(% style="width:214px" %)sed_information_model|(% style="width:676px" %)A System Information Model Management Service|(% style="width:358px" %)
341 +|(((
342 +1.
343 +)))|(% style="width:214px" %)sed_events_configurator|(% style="width:676px" %)A System Event Configuration Service|(% style="width:358px" %)
344 +|(((
345 +1.
346 +)))|(% style="width:214px" %)sed_information_model_editor|(% style="width:676px" %)A service for editing the information model|(% style="width:358px" %)
347 +|(% colspan="4" %)**Server Backup Services**
348 +|(((
349 +1.
350 +)))|(% style="width:214px" %)sed_coordinator|(% style="width:676px" %)A service for selecting the cluster's host server using the Bully leader election algorithm|(% style="width:358px" %)
351 +|(((
352 +1.
353 +)))|(% style="width:214px" %)sed_reserve|(% style="width:676px" %)A service for displaying a list of backup servers|(% style="width:358px" %)
354 +|(((
355 +1.
356 +)))|(% style="width:214px" %)sed_replicator|(% style="width:676px" %)A log replication service between cluster servers|(% style="width:358px" %)
357 +|(((
358 +1.
359 +)))|(% style="width:214px" %)sed_influx_replicator|(% style="width:676px" %)A data replication service (archives and telemetry) between cluster servers|(% style="width:358px" %)
360 +|(((
361 +1.
362 +)))|(% style="width:214px" %)sed_events_replicator|(% style="width:676px" %)An event replication service between cluster servers|(% style="width:358px" %)
363 +|(((
364 +1.
365 +)))|(% style="width:214px" %)sed_fs_synch|(% style="width:676px" %)A data replication service (gob files, reports, waveforms) between cluster servers|(% style="width:358px" %)