Changes for page 4. Structure and Modules Description
Last modified by Iaroslav Platonov on 2026/06/08 10:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -74,4 +74,308 @@ 74 74 75 75 Table 1 – CENTO software components 76 76 77 - 77 +|(% style="text-align:center" %)**№**|(% style="text-align:center; width:214px" %)**Service Name**|(% style="text-align:center; width:676px" %)**Function**|(% style="text-align:center; width:358px" %)**Metrologically significant part** 78 +|(% colspan="4" style="text-align:center" %)**Data collection and transmission services** 79 +|((( 80 +~1. 81 +)))|(% style="width:214px" %)sed_bus_dispatcher|(% style="width:676px" %)Sequential Device Polling Management Service|(% style="width:358px" %) 82 +|((( 83 +2. 84 +)))|(% style="width:214px" %)sed_xml_reader|(% style="width:676px" %)Service for processing received XML files 80020|(% style="width:358px" %) 85 +|((( 86 +3. 87 +)))|(% style="width:214px" %)sed_xml_send|(% style="width:676px" %)XML file transfer Service 80020|(% style="width:358px" %) 88 +|((( 89 +4. 90 +)))|(% style="width:214px" %)sed_archive_webapi|(% style="width:676px" %)Implementation of the web API for transmitting archived data according to the CENTO documentation|(% style="width:358px" %) 91 +|((( 92 +5. 93 +)))|(% style="width:214px" %)sed_s2s_configuration|(% style="width:676px" %)Configuration transmission service between CENTO servers|(% style="width:358px" %) 94 +|(% colspan="4" style="text-align:center" %)**Data collection and transmission services using standard protocols** 95 +|6.|(% style="width:214px" %)sed_modbus_rtd|(% style="width:676px" %)A service for reading real-time data from devices using Modbus protocol (Modbus TCP and Modbus RTU over TCP)|(% style="width:358px" %)sed_metrology_001.bin 96 +|7.|(% style="width:214px" %)sed_modbus_rtd_send|(% style="width:676px" %)A service for sending real-time data to third-party devices using the Modbus TCP protocol|(% style="width:358px" %) 97 +|8.|(% style="width:214px" %)sed_modbus_sync|(% style="width:676px" %)A device time synchronization service using Modbus protocol (Modbus TCP and Modbus RTU over TCP)|(% style="width:358px" %) 98 +|9.|(% style="width:214px" %)sed_snmp_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the SNMP (v1, v2c, v3), ICMP protocols|(% style="width:358px" %) 99 +|10.|(% style="width:214px" %)sed_iec103_waveform|(% style="width:676px" %)A service for reading waveform files from devices using the IEC protocol-60870-5-103|(% style="width:358px" %)sed_metrology_393.bin 100 +|11.|(% style="width:214px" %)sed_iec104_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the IEC 60870-5-104 protocol|(% style="width:358px" %)sed_metrology_011.bin 101 +|12.|(% style="width:214px" %)sed_iec104_rtd_send|(% style="width:676px" %)A service for sending real-time data to third-party devices using the IEC 60870-5-104 protocol|(% style="width:358px" %)sed_metrology_012.bin 102 +|13.|(% style="width:214px" %)sed_opcda_rtd|(% style="width:676px" %)A service for receiving real-time data using the OPC DA protocol|(% style="width:358px" %) 103 +|14.|(% style="width:214px" %)sed_opcua_rtd|(% style="width:676px" %)A service for receiving real-time data using the OPC UA protocol|(% style="width:358px" %) 104 +|15.|(% style="width:214px" %)sed_opcua_arch|(% style="width:676px" %)A service for receiving archived data using the OPC UA protocol|(% style="width:358px" %)sed_metrology_402.bin 105 +|16.|(% style="width:214px" %)sed_opcua_server|(% style="width:676px" %)A service for transmitting data using the OPC UA protocol|(% style="width:358px" %) 106 +|17.|(% style="width:214px" %)sed_dnp3_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the DNP3 protocol|(% style="width:358px" %) 107 +|18.|(% style="width:214px" %)sed_ftp_waveform|(% style="width:676px" %)A service for receiving waveform files via FTP protocol|(% style="width:358px" %)sed_metrology_380.bin 108 +|19.|(% style="width:214px" %)sed_iec61107_rtd|(% style="width:676px" %)A service for obtaining real-time data from devices using the IEC 62056-21 protocol|(% style="width:358px" %)sed_metrology_61107.bin 109 +|20.|(% style="width:214px" %)sed_iec61850_arch|(% style="width:676px" %)A service for receiving archived data from devices using the IEC 61850 protocol|(% style="width:358px" %) 110 +|21.|(% style="width:214px" %)sed_iec61850_rtd|(% style="width:676px" %)A service for receiving operational data from devices using the IEC 61850 protocol|(% style="width:358px" %) 111 +|(% colspan="4" style="text-align:center" %)**Proprietary protocol data collection and transmission services** 112 +|22.|(% style="width:214px" %)sed_satec_arch|(% style="width:676px" %)A service for reading archived data (metering and event logs) from SATEC devices|(% style="width:358px" %)sed_metrology_7_8.bin 113 +|23.|(% style="width:214px" %)sed_satec_pq_journal|(% style="width:676px" %)A service for obtaining event logs for monitoring the power quality from Satec devices|(% style="width:358px" %)sed_metrology_106.bin 114 +|24.|(% style="width:214px" %)sed_satec_pq_report|(% style="width:676px" %)A service for receiving reports on the power quality control from Satec devices|(% style="width:358px" %)sed_metrology_106.bin 115 +|25.|(% style="width:214px" %)sed_satec_waveforms|(% style="width:676px" %)A service for proofreading waveforms from SATEC devices using Modbus TCP and RTU over TCP protocols|(% style="width:358px" %)sed_metrology_108_109.bin 116 +|26.|(% style="width:214px" %)sed_iec103_rtd|(% style="width:676px" %)A service for reading real-time data from TOR 200 terminals according to the IEC protocol-60870-5-103|(% style="width:358px" %)sed_metrology_391.bin 117 +|27.|(% style="width:214px" %)sed_sepam_waveform|(% style="width:676px" %)A service for proofreading waveforms and time synchronization using the Modbus RTU over TCP protocol from Sepam devices|(% style="width:358px" %)sed_metrology_298_299.bin 118 +|28.|(% style="width:214px" %)sed_rtu_over_tcp_logikamp_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the LogicaMP RTU over TCP protocol|(% style="width:358px" %)sed_metrology_121.bin 119 +|29.|(% style="width:214px" %)sed_rtu_over_tcp_logikamp_arch|(% style="width:676px" %)A service for reading archived data from devices using the LogicaMP RTU over TCP protocol|(% style="width:358px" %)sed_metrology_122.bin 120 +|30.|(% style="width:214px" %)sed_axis_video_journal|(% style="width:676px" %)An AXIS camera recording service|(% style="width:358px" %)sed_metrology_435.bin 121 +|31.|(% style="width:214px" %)sed_vzlyotmb_arch|(% style="width:676px" %)A service for reading archives and event logs of devices Vzlet TSRV-043, TSRV-027, IVK-TER|(% style="width:358px" %)sed_metrology_25_133.bin 122 +|32.|(% style="width:214px" %)sed_micom_waveforms|(% style="width:676px" %)A service for reading waveform files from Micom devices using Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_370.bin 123 +|33.|(% style="width:214px" %)sed_pulsar_arch|(% style="width:676px" %)A service for reading archives from Pulsar devices using the Modbus protocol|(% style="width:358px" %)sed_metrology_342.bin 124 +|34.|(% style="width:214px" %)sed_rtu_over_tcp_a1800_arch|(% style="width:676px" %)A service for receiving archived data from A1800 meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_232.bin 125 +|35.|(% style="width:214px" %)sed_rtu_over_tcp_a1800_rtd|(% style="width:676px" %)A service for receiving real-time data from A1800 meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_231.bin 126 +|36.|(% style="width:214px" %)sed_rtu_over_tcp_acron_arch|(% style="width:676px" %)A service for receiving archived data from Acron meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_142.bin 127 +|37.|(% style="width:214px" %)sed_rtu_over_tcp_acron_rtd|(% style="width:676px" %)A service for receiving real-time data from Acron meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_141.bin 128 +|38.|(% style="width:214px" %)sed_rtu_over_tcp_bmrz_waveform|(% style="width:676px" %)A service for reading waveform files from BMRZ terminals using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_110.bin 129 +|39.|(% style="width:214px" %)sed_rtu_over_tcp_bzp03_waveform|(% style="width:676px" %)A service for reading waveform files from BZP-03 terminals using Modbus RTU over TCP protocol|(% style="width:358px" %) 130 +|40.|(% style="width:214px" %)sed_rtu_over_tcp_kmp_rtd|(% style="width:676px" %)A service for polling Multitical 601 device using the KMP protocol|(% style="width:358px" %)sed_metrology_191.bin 131 +|41.|(% style="width:214px" %)sed_rtu_over_tcp_majac_arch|(% style="width:676px" %)A service for receiving archived data from devices using the Mayak protocol|(% style="width:358px" %)sed_metrology_152.bin 132 +|42.|(% style="width:214px" %)sed_rtu_over_tcp_mercury200_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the Mercury 200 protocol|(% style="width:358px" %)sed_metrology_251.bin 133 +|43.|(% style="width:214px" %)sed_rtu_over_tcp_mercury_arch|(% style="width:676px" %)A service for reading archives and event logs from Mercury-230 series devices using the Mercury-230 protocol|(% style="width:358px" %)sed_metrology_202.bin 134 +|44.|(% style="width:214px" %)sed_rtu_over_tcp_mercury_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the Mercury 230 protocol|(% style="width:358px" %)sed_metrology_201.bin 135 +|45.|(% style="width:214px" %)sed_rtu_over_tcp_photon_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the photon RTU over TCP protocol|(% style="width:358px" %)sed_metrology_221.bin 136 +|46.|(% style="width:214px" %)sed_rtu_over_tcp_ref542plus_waveform|(% style="width:676px" %)Proofreading of waveforms and time synchronization via Modbus RTU over TCP protocol from ABB REF 542plus devices|(% style="width:358px" %) 137 +|47.|(% style="width:214px" %)sed_rtu_over_tcp_set4tm_arch|(% style="width:676px" %)A service for polling SET-4TM, PSC meters’ archives|(% style="width:358px" %)sed_metrology_112.bin 138 +|48.|(% style="width:214px" %)sed_rtu_over_tcp_set4tm_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the SET-4TM rtu over tcp protocol|(% style="width:358px" %)sed_metrology_111.bin 139 +|49.|(% style="width:214px" %)sed_rtu_over_tcp_tem104_arch|(% style="width:676px" %)A service for receiving archived data from devices using the TEM104 protocol|(% style="width:358px" %)sed_metrology_162.bin 140 +|50.|(% style="width:214px" %)sed_rtu_over_tcp_tem104_rtd|(% style="width:676px" %)A service for receiving real-tume data from devices using the TEM104 protocol|(% style="width:358px" %)sed_metrology_161.bin 141 +|51.|(% style="width:214px" %)sed_rtu_over_tcp_vist_arch|(% style="width:676px" %)A service for receiving archived data from devices using the VIS.T protocol|(% style="width:358px" %)sed_metrology_172.bin 142 +|52.|(% style="width:214px" %)sed_rtu_over_tcp_vkt5_arch|(% style="width:676px" %)A service for receiving archived data from VKT-5 devices|(% style="width:358px" %)sed_metrology_312.bin 143 +| |(% style="width:214px" %)sed_rtu_over_tcp_vkt5_rtd|(% style="width:676px" %)A service for receiving real-time data from VKT-5 devices|(% style="width:358px" %)sed_metrology_311.bin 144 +| |(% style="width:214px" %)sed_vkt7_arch|(% style="width:676px" %)A service for receiving archived data from VKT-7 devices|(% style="width:358px" %) 145 +| |(% style="width:214px" %)sed_vkt7_rtd|(% style="width:676px" %)A service for receiving real-time data from VKT-7 devices|(% style="width:358px" %) 146 +| |(% style="width:214px" %)sed_rtu_over_tcp_vtd_arch|(% style="width:676px" %)A service for receiving archived data of VTD devices|(% style="width:358px" %)sed_metrology_182.bin 147 +| |(% style="width:214px" %)sed_rtu_over_tcp_vtd_rtd|(% style="width:676px" %)A service for receiving operational data from VTD devices|(% style="width:358px" %)sed_metrology_181.bin 148 +| |(% style="width:214px" %)sed_uvp_arch|(% style="width:676px" %)A service for poling Promavtomatika's archive for devices of the UVP series|(% style="width:358px" %)sed_metrology_352.bin 149 +| |(% style="width:214px" %)sed_ce_arch|(% style="width:676px" %)A service for receiving archived data from Energomera devices of the CE series according to the IEC61107 protocol|(% style="width:358px" %)sed_metrology_362.bin 150 +| |(% style="width:214px" %)sed_alpha_arch|(% style="width:676px" %)A service for receiving archived data from Alfa-3 devices manufactured by Alfamera|(% style="width:358px" %)sed_metrology_462_472.bin 151 +| |(% style="width:214px" %)sed_bug01_rtd|(% style="width:676px" %)A service for receiving archived data of BUG-01 devices|(% style="width:358px" %)sed_metrology_491.bin 152 +| |(% style="width:214px" %)sed_dymetic_arch|(% style="width:676px" %)A service for receiving archived data from Dimetik|(% style="width:358px" %)sed_metrology_552.bin 153 +| |(% style="width:214px" %)sed_irvis_arch|(% style="width:676px" %)A service for receiving archived data from devices using the Irvis protocol|(% style="width:358px" %)sed_metrology_442.bin 154 +| |(% style="width:214px" %)sed_karat_arch|(% style="width:676px" %)A service for receiving archived data from Karat devices|(% style="width:358px" %)sed_metrology_512.bin 155 +| |(% style="width:214px" %)sed_lis200_arch|(% style="width:676px" %)A service for receiving archived data from the EK-260 and EK-270 devices manufactured by Elster|(% style="width:358px" %)sed_metrology_452.bin 156 +| |(% style="width:214px" %)sed_rtu_over_tcp_sepam_waveform|(% style="width:676px" %)A service for reading waveform files from Sepam devices using Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_298.bin 157 +|(% colspan="4" style="text-align:center" %)**Data export and import services in SQL databases** 158 +| |(% style="width:214px" %)sed_sql_rtd|(% style="width:676px" %)A service for receiving tele-measurement data from MySQL|(% style="width:358px" %)sed_metrology_211.bin 159 +| |(% style="width:214px" %)sed_sql_arch|(% style="width:676px" %)A service for archived data retrieval from Microsoft SQL Server|(% style="width:358px" %) 160 +| |(% style="width:214px" %)sed_sql_arch_send|(% style="width:676px" %)A service for recording archived data in an external SQL database|(% style="width:358px" %) 161 +|(% colspan="4" style="text-align:center" %)**Data processing services** 162 +|((( 163 +1. 164 +)))|(% style="width:214px" %)sed_controller|(% style="width:676px" %)A service for telemetry reception and processing (writes to the InfluxDB database)|(% style="width:358px" %)sed_metrology_controller.bin 165 +|((( 166 +1. 167 +)))|(% style="width:214px" %)sed_events_calc|(% style="width:676px" %)A service for generating event based on the conditions specified in the configuration|(% style="width:358px" %) 168 +|((( 169 +1. 170 +)))|(% style="width:214px" %)sed_calc_arch|(% style="width:676px" %)A service for calculating metering channels|(% style="width:358px" %)((( 171 +sed_metrology_calc_arch.bin 172 + 173 +sed_metrology_formulas.bin 174 +))) 175 +|((( 176 +1. 177 +)))|(% style="width:214px" %)sed_calc_rtd|(% style="width:676px" %)A service for calculating pre-calculated tags|(% style="width:358px" %) 178 +|((( 179 +1. 180 +)))|(% style="width:214px" %)sed_round_arch|(% style="width:676px" %)A service for calculating metering channels with rounding|(% style="width:358px" %)sed_metrology_round_arch.bin 181 +|((( 182 +1. 183 +)))|(% style="width:214px" %)sed_energy_calc|(% style="width:676px" %)A service for server-level energy resource calculation|(% style="width:358px" %)sed_metrology_411_421.bin 184 +|((( 185 +1. 186 +)))|(% style="width:214px" %)sed_loadflow_calc|(% style="width:676px" %)A service for calculating modes based on an information model|(% style="width:358px" %) 187 +|((( 188 +1. 189 +)))|(% style="width:214px" %)sed_storage_writer|(% style="width:676px" %)A service for recording archived data (metering and event logs) in a data storage (InfluxDB and MongoDB)|(% style="width:358px" %) 190 +|(% colspan="4" %)**Web Part Services** 191 +|((( 192 +1. 193 +)))|(% style="width:214px" %)php5-cgi|(% style="width:676px" %)A Web Query Service|(% style="width:358px" %) 194 +|((( 195 +1. 196 +)))|(% style="width:214px" %)nginx|(% style="width:676px" %)A Web Server|(% style="width:358px" %) 197 +|((( 198 +1. 199 +)))|(% style="width:214px" %)sed_ui|(% style="width:676px" %)A service for processing requests for web resources (js, css, html files)|(% style="width:358px" %) 200 +|((( 201 +1. 202 +)))|(% style="width:214px" %)sed_rtd_analysis|(% style="width:676px" %)A service for analyzing real-time data|(% style="width:358px" %) 203 +|((( 204 +1. 205 +)))|(% style="width:214px" %)sed_auth|(% style="width:676px" %)A service for authenticating and authorizing users in the system and configuring access rights|(% style="width:358px" %) 206 +|((( 207 +1. 208 +)))|(% style="width:214px" %)sed_auth_privileges|(% style="width:676px" %)A User Privilege Management Service|(% style="width:358px" %) 209 +|((( 210 +1. 211 +)))|(% style="width:214px" %)sed_api_gateway|(% style="width:676px" %)A service for proxying of web requests to other services within the system|(% style="width:358px" %) 212 +|((( 213 +1. 214 +)))|(% style="width:214px" %)sed_dataset_configurator|(% style="width:676px" %)A service for working with datasets|(% style="width:358px" %) 215 +|((( 216 +1. 217 +)))|(% style="width:214px" %)sed_rtd|(% style="width:676px" %)A real-time data subscription service|(% style="width:358px" %) 218 +|((( 219 +1. 220 +)))|(% style="width:214px" %)sed_rtd_archive|(% style="width:676px" %)A service for generating archived data from real-time data|(% style="width:358px" %) 221 +|((( 222 +1. 223 +)))|(% style="width:214px" %)sed_system|(% style="width:676px" %)A service that provides a user interface with information about the system|(% style="width:358px" %) 224 +|((( 225 +1. 226 +)))|(% style="width:214px" %)sed_archive|(% style="width:676px" %)A service that provides user interfaces for analyzing electricity and energy accounting|(% style="width:358px" %) 227 +|((( 228 +1. 229 +)))|(% style="width:214px" %)sed_archive_integrity|(% style="width:676px" %)A service that provides user interfaces for analyzing the completeness of electricity and energy resources data|(% style="width:358px" %) 230 +|((( 231 +1. 232 +)))|(% style="width:214px" %)sed_pq_reports|(% style="width:676px" %)A service for working with power quality reports|(% style="width:358px" %) 233 +|((( 234 +1. 235 +)))|(% style="width:214px" %)sed_pq_journal|(% style="width:676px" %)A service for working with power quality logs|(% style="width:358px" %) 236 +|((( 237 +1. 238 +)))|(% style="width:214px" %)sed_ras_configurator|(% style="width:676px" %)A service for configuring emergency event loggers|(% style="width:358px" %) 239 +|((( 240 +1. 241 +)))|(% style="width:214px" %)sed_reports|(% style="width:676px" %)A service for generating and managing reports, and maintaining user interfaces for reports|(% style="width:358px" %) 242 +|((( 243 +1. 244 +)))|(% style="width:214px" %)sed_widgets|(% style="width:676px" %)A service for the user interfaces of drag'n'drop widgets|(% style="width:358px" %) 245 +|((( 246 +1. 247 +)))|(% style="width:214px" %)sed_menu|(% style="width:676px" %)A service for displaying and configuring CENTO system menu|(% style="width:358px" %) 248 +|((( 249 +1. 250 +)))|(% style="width:214px" %)sed_mnemonic_diagrams|(% style="width:676px" %)A service for the user interfaces of diagrams v2|(% style="width:358px" %) 251 +|((( 252 +1. 253 +)))|(% style="width:214px" %)sed_configuration|(% style="width:676px" %)A service for user interfaces for system configuration (alerts, mail servers, formulas, device trees)|(% style="width:358px" %) 254 +|((( 255 +1. 256 +)))|(% style="width:214px" %)sed_devices_configurator|(% style="width:676px" %)A service for editing device configurations, tags, and channels|(% style="width:358px" %) 257 +|((( 258 +1. 259 +)))|(% style="width:214px" %)sed_common_event_journal|(% style="width:676px" %)A service for user interfaces for generalized configurable event logs|(% style="width:358px" %) 260 +|((( 261 +1. 262 +)))|(% style="width:214px" %)sed_device_event_journal|(% style="width:676px" %)A Device Log Service|(% style="width:358px" %) 263 +|((( 264 +1. 265 +)))|(% style="width:214px" %)sed_operative_journal|(% style="width:676px" %)A service for the user interface of the real-time event log|(% style="width:358px" %) 266 +|((( 267 +1. 268 +)))|(% style="width:214px" %)sed_video_journal|(% style="width:676px" %)A Video Camera Log Service|(% style="width:358px" %) 269 +|((( 270 +1. 271 +)))|(% style="width:214px" %)sed_marking|(% style="width:676px" %)A Dispatch Tag Management Service|(% style="width:358px" %) 272 +|((( 273 +1. 274 +)))|(% style="width:214px" %)sed_sounds|(% style="width:676px" %)A service for the user interface for sound alerts management|(% style="width:358px" %) 275 +|((( 276 +1. 277 +)))|(% style="width:214px" %)sed_video_stream|(% style="width:676px" %)A service for streaming video from cameras registered in the information model|(% style="width:358px" %) 278 +|(% colspan="4" %)**System services** 279 +|((( 280 +1. 281 +)))|(% style="width:214px" %)nats|(% style="width:676px" %)A message broker and a service registry (service registry/service discovery)|(% style="width:358px" %) 282 +|((( 283 +1. 284 +)))|(% style="width:214px" %)influxdb|(% style="width:676px" %)A time series database|(% style="width:358px" %) 285 +|((( 286 +1. 287 +)))|(% style="width:214px" %)mongod|(% style="width:676px" %)A database of configuration and structured data (event logs, requests)|(% style="width:358px" %) 288 +|((( 289 +1. 290 +)))|(% style="width:214px" %)sed_signals|(% style="width:676px" %)A signal reception and transmission service inside the system (remote control, configuration update, manual polling, parameter recalculation)|(% style="width:358px" %) 291 +|((( 292 +1. 293 +)))|(% style="width:214px" %)sed_debug|(% style="width:676px" %)A service for providing access to debugging information of CENTO services|(% style="width:358px" %) 294 +|((( 295 +1. 296 +)))|(% style="width:214px" %)sed_graphql|(% style="width:676px" %)A subscription service for device statuses|(% style="width:358px" %) 297 +|((( 298 +1. 299 +)))|(% style="width:214px" %)sed_energy_calc_configuration|(% style="width:676px" %)A service for creating, changing, and deleting energy resource calculation configurations at the server level|(% style="width:358px" %) 300 +|((( 301 +1. 302 +)))|(% style="width:214px" %)sed_backup|(% style="width:676px" %)A service for backing up data according to the cron rule.|(% style="width:358px" %) 303 +|((( 304 +1. 305 +)))|(% style="width:214px" %)sed_channels|(% style="width:676px" %)A channel subscription service|(% style="width:358px" %) 306 +|((( 307 +1. 308 +)))|(% style="width:214px" %)sed_channels_data|(% style="width:676px" %)A subscription service for protocol statuses and the latest channel data|(% style="width:358px" %) 309 +|((( 310 +1. 311 +)))|(% style="width:214px" %)sed_emission_archive|(% style="width:676px" %)A service for providing emissions metering data|(% style="width:358px" %) 312 +|((( 313 +1. 314 +)))|(% style="width:214px" %)sed_profile_archive|(% style="width:676px" %)A service for providing metering data from InfluxDB via gRPC.|(% style="width:358px" %) 315 +|((( 316 +1. 317 +)))|(% style="width:214px" %)sed_web_storage|(% style="width:676px" %)A service for accessing archived metering data|(% style="width:358px" %) 318 +|((( 319 +1. 320 +)))|(% style="width:214px" %)sed_watchdog|(% style="width:676px" %)A service for managing the launch of CENTO services|(% style="width:358px" %) 321 +|((( 322 +1. 323 +)))|(% style="width:214px" %)sed_scheduler|(% style="width:676px" %)A service for launching scheduled tasks|(% style="width:358px" %) 324 +|((( 325 +1. 326 +)))|(% style="width:214px" %)sed_license|(% style="width:676px" %)A licensing service|(% style="width:358px" %) 327 +|((( 328 +1. 329 +)))|(% style="width:214px" %)sed_monitor|(% style="width:676px" %)A service for monitoring the operation of the system's services and applications|(% style="width:358px" %) 330 +|((( 331 +1. 332 +)))|(% style="width:214px" %)sed_telecontrol|(% style="width:676px" %)A remote control service|(% style="width:358px" %) 333 +|((( 334 +1. 335 +)))|(% style="width:214px" %)sed_notificator|(% style="width:676px" %)A service for notifying users about events by e-mail|(% style="width:358px" %) 336 +|((( 337 +1. 338 +)))|(% style="width:214px" %)sed_waveforms_journal|(% style="width:676px" %)A waveform Log Service|(% style="width:358px" %) 339 +|((( 340 +1. 341 +)))|(% style="width:214px" %)sed_storage_configurator|(% style="width:676px" %)An InfluxDB Database Configuration Service|(% style="width:358px" %) 342 +|((( 343 +1. 344 +)))|(% style="width:214px" %)sed_system_configuration|(% style="width:676px" %)A CENTO System Configuration Editing Service|(% style="width:358px" %) 345 +|((( 346 +1. 347 +)))|(% style="width:214px" %)sed_user_settings|(% style="width:676px" %)A User Settings Configuration Service|(% style="width:358px" %) 348 +|((( 349 +1. 350 +)))|(% style="width:214px" %)sed_system_event_journal|(% style="width:676px" %)A service for registration and provision of system events (business logic and administration)|(% style="width:358px" %) 351 +|((( 352 +1. 353 +)))|(% style="width:214px" %)sed_tech_event_journal|(% style="width:676px" %)A service for processing and managing technological events|(% style="width:358px" %) 354 +|((( 355 +1. 356 +)))|(% style="width:214px" %)sed_information_model|(% style="width:676px" %)A System Information Model Management Service|(% style="width:358px" %) 357 +|((( 358 +1. 359 +)))|(% style="width:214px" %)sed_events_configurator|(% style="width:676px" %)A System Event Configuration Service|(% style="width:358px" %) 360 +|((( 361 +1. 362 +)))|(% style="width:214px" %)sed_information_model_editor|(% style="width:676px" %)A service for editing the information model|(% style="width:358px" %) 363 +|(% colspan="4" %)**Server Backup Services** 364 +|((( 365 +1. 366 +)))|(% style="width:214px" %)sed_coordinator|(% style="width:676px" %)A service for selecting the cluster's host server using the Bully leader election algorithm|(% style="width:358px" %) 367 +|((( 368 +1. 369 +)))|(% style="width:214px" %)sed_reserve|(% style="width:676px" %)A service for displaying a list of backup servers|(% style="width:358px" %) 370 +|((( 371 +1. 372 +)))|(% style="width:214px" %)sed_replicator|(% style="width:676px" %)A log replication service between cluster servers|(% style="width:358px" %) 373 +|((( 374 +1. 375 +)))|(% style="width:214px" %)sed_influx_replicator|(% style="width:676px" %)A data replication service (archives and telemetry) between cluster servers|(% style="width:358px" %) 376 +|((( 377 +1. 378 +)))|(% style="width:214px" %)sed_events_replicator|(% style="width:676px" %)An event replication service between cluster servers|(% style="width:358px" %) 379 +|((( 380 +1. 381 +)))|(% style="width:214px" %)sed_fs_synch|(% style="width:676px" %)A data replication service (gob files, reports, waveforms) between cluster servers|(% style="width:358px" %)