Last modified by Iaroslav Platonov on 2026/06/08 10:08

From version 6.2
edited by Lana
on 2025/12/03 21:51
Change comment: There is no comment for this version
To version 6.4
edited by Lana
on 2025/12/03 21:53
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -74,4 +74,436 @@
74 74  
75 75  Table 1 – CENTO software components
76 76  
77 -
77 +|(% style="text-align:center" %)**№**|(% style="text-align:center; width:214px" %)**Service Name**|(% style="text-align:center; width:676px" %)**Function**|(% style="text-align:center; width:358px" %)**Metrologically significant part**
78 +|(% colspan="4" style="text-align:center" %)**Data collection and transmission services**
79 +|(((
80 +~1.
81 +)))|(% style="width:214px" %)sed_bus_dispatcher|(% style="width:676px" %)Sequential Device Polling Management Service|(% style="width:358px" %)
82 +|(((
83 +2.
84 +)))|(% style="width:214px" %)sed_xml_reader|(% style="width:676px" %)Service for processing received XML files 80020|(% style="width:358px" %)
85 +|(((
86 +3.
87 +)))|(% style="width:214px" %)sed_xml_send|(% style="width:676px" %)XML file transfer Service 80020|(% style="width:358px" %)
88 +|(((
89 +4.
90 +)))|(% style="width:214px" %)sed_archive_webapi|(% style="width:676px" %)Implementation of the web API for transmitting archived data according to the CENTO documentation|(% style="width:358px" %)
91 +|(((
92 +1.
93 +)))|(% style="width:214px" %)sed_s2s_configuration|(% style="width:676px" %)Configuration transmission service between CENTO servers|(% style="width:358px" %)
94 +|(% colspan="4" %)**Data collection and transmission services using standard protocols**
95 +|(((
96 +1.
97 +)))|(% style="width:214px" %)sed_modbus_rtd|(% style="width:676px" %)A service for reading real-time data from devices using Modbus protocol (Modbus TCP and Modbus RTU over TCP)|(% style="width:358px" %)sed_metrology_001.bin
98 +|(((
99 +1.
100 +)))|(% style="width:214px" %)sed_modbus_rtd_send|(% style="width:676px" %)A service for sending real-time data to third-party devices using the Modbus TCP protocol|(% style="width:358px" %)
101 +|(((
102 +1.
103 +)))|(% style="width:214px" %)sed_modbus_sync|(% style="width:676px" %)A device time synchronization service using Modbus protocol (Modbus TCP and Modbus RTU over TCP)|(% style="width:358px" %)
104 +|(((
105 +1.
106 +)))|(% style="width:214px" %)sed_snmp_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the SNMP (v1, v2c, v3), ICMP protocols|(% style="width:358px" %)
107 +|(((
108 +1.
109 +)))|(% style="width:214px" %)sed_iec103_waveform|(% style="width:676px" %)A service for reading waveform files from devices using the IEC protocol-60870-5-103|(% style="width:358px" %)sed_metrology_393.bin
110 +|(((
111 +1.
112 +)))|(% style="width:214px" %)sed_iec104_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the IEC 60870-5-104 protocol|(% style="width:358px" %)sed_metrology_011.bin
113 +|(((
114 +1.
115 +)))|(% style="width:214px" %)sed_iec104_rtd_send|(% style="width:676px" %)A service for sending real-time data to third-party devices using the IEC 60870-5-104 protocol|(% style="width:358px" %)sed_metrology_012.bin
116 +|(((
117 +1.
118 +)))|(% style="width:214px" %)sed_opcda_rtd|(% style="width:676px" %)A service for receiving real-time data using the OPC DA protocol|(% style="width:358px" %)
119 +|(((
120 +1.
121 +)))|(% style="width:214px" %)sed_opcua_rtd|(% style="width:676px" %)A service for receiving real-time data using the OPC UA protocol|(% style="width:358px" %)
122 +|(((
123 +1.
124 +)))|(% style="width:214px" %)sed_opcua_arch|(% style="width:676px" %)A service for receiving archived data using the OPC UA protocol|(% style="width:358px" %)sed_metrology_402.bin
125 +|(((
126 +1.
127 +)))|(% style="width:214px" %)sed_opcua_server|(% style="width:676px" %)A service for transmitting data using the OPC UA protocol|(% style="width:358px" %)
128 +|(((
129 +1.
130 +)))|(% style="width:214px" %)sed_dnp3_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the DNP3 protocol|(% style="width:358px" %)
131 +|(((
132 +1.
133 +)))|(% style="width:214px" %)sed_ftp_waveform|(% style="width:676px" %)A service for receiving waveform files via FTP protocol|(% style="width:358px" %)sed_metrology_380.bin
134 +|(((
135 +1.
136 +)))|(% style="width:214px" %)sed_iec61107_rtd|(% style="width:676px" %)A service for obtaining real-time data from devices using the IEC 62056-21 protocol|(% style="width:358px" %)sed_metrology_61107.bin
137 +|(((
138 +1.
139 +)))|(% style="width:214px" %)sed_iec61850_arch|(% style="width:676px" %)A service for receiving archived data from devices using the IEC 61850 protocol|(% style="width:358px" %)
140 +|(((
141 +1.
142 +)))|(% style="width:214px" %)sed_iec61850_rtd|(% style="width:676px" %)A service for receiving operational data from devices using the IEC 61850 protocol|(% style="width:358px" %)
143 +|(% colspan="4" %)**Proprietary protocol data collection and transmission services**
144 +|(((
145 +1.
146 +)))|(% style="width:214px" %)sed_satec_arch|(% style="width:676px" %)A service for reading archived data (metering and event logs) from SATEC devices|(% style="width:358px" %)sed_metrology_7_8.bin
147 +|(((
148 +1.
149 +)))|(% style="width:214px" %)sed_satec_pq_journal|(% style="width:676px" %)A service for obtaining event logs for monitoring the power quality from Satec devices|(% style="width:358px" %)sed_metrology_106.bin
150 +|(((
151 +1.
152 +)))|(% style="width:214px" %)sed_satec_pq_report|(% style="width:676px" %)A service for receiving reports on the power quality control from Satec devices|(% style="width:358px" %)sed_metrology_106.bin
153 +|(((
154 +1.
155 +)))|(% style="width:214px" %)sed_satec_waveforms|(% style="width:676px" %)A service for proofreading waveforms from SATEC devices using Modbus TCP and RTU over TCP protocols|(% style="width:358px" %)sed_metrology_108_109.bin
156 +|(((
157 +1.
158 +)))|(% style="width:214px" %)sed_iec103_rtd|(% style="width:676px" %)A service for reading real-time data from TOR 200 terminals according to the IEC protocol-60870-5-103|(% style="width:358px" %)sed_metrology_391.bin
159 +|(((
160 +1.
161 +)))|(% style="width:214px" %)sed_sepam_waveform|(% style="width:676px" %)A service for proofreading waveforms and time synchronization using the Modbus RTU over TCP protocol from Sepam devices|(% style="width:358px" %)sed_metrology_298_299.bin
162 +|(((
163 +1.
164 +)))|(% style="width:214px" %)sed_rtu_over_tcp_logikamp_rtd|(% style="width:676px" %)A service for reading real-time data from devices using the LogicaMP RTU over TCP protocol|(% style="width:358px" %)sed_metrology_121.bin
165 +|(((
166 +1.
167 +)))|(% style="width:214px" %)sed_rtu_over_tcp_logikamp_arch|(% style="width:676px" %)A service for reading archived data from devices using the LogicaMP RTU over TCP protocol|(% style="width:358px" %)sed_metrology_122.bin
168 +|(((
169 +1.
170 +)))|(% style="width:214px" %)sed_axis_video_journal|(% style="width:676px" %)An AXIS camera recording service|(% style="width:358px" %)sed_metrology_435.bin
171 +|(((
172 +1.
173 +)))|(% style="width:214px" %)sed_vzlyotmb_arch|(% style="width:676px" %)A service for reading archives and event logs of devices Vzlet TSRV-043, TSRV-027, IVK-TER|(% style="width:358px" %)sed_metrology_25_133.bin
174 +|(((
175 +1.
176 +)))|(% style="width:214px" %)sed_micom_waveforms|(% style="width:676px" %)A service for reading waveform files from Micom devices using Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_370.bin
177 +|(((
178 +1.
179 +)))|(% style="width:214px" %)sed_pulsar_arch|(% style="width:676px" %)A service for reading archives from Pulsar devices using the Modbus protocol|(% style="width:358px" %)sed_metrology_342.bin
180 +|(((
181 +1.
182 +)))|(% style="width:214px" %)sed_rtu_over_tcp_a1800_arch|(% style="width:676px" %)A service for receiving archived data from A1800 meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_232.bin
183 +|(((
184 +1.
185 +)))|(% style="width:214px" %)sed_rtu_over_tcp_a1800_rtd|(% style="width:676px" %)A service for receiving real-time data from A1800 meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_231.bin
186 +|(((
187 +1.
188 +)))|(% style="width:214px" %)sed_rtu_over_tcp_acron_arch|(% style="width:676px" %)A service for receiving archived data from Acron meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_142.bin
189 +|(((
190 +1.
191 +)))|(% style="width:214px" %)sed_rtu_over_tcp_acron_rtd|(% style="width:676px" %)A service for receiving real-time data from Acron meters using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_141.bin
192 +|(((
193 +1.
194 +)))|(% style="width:214px" %)sed_rtu_over_tcp_bmrz_waveform|(% style="width:676px" %)A service for reading waveform files from BMRZ terminals using the Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_110.bin
195 +|(((
196 +1.
197 +)))|(% style="width:214px" %)sed_rtu_over_tcp_bzp03_waveform|(% style="width:676px" %)A service for reading waveform files from BZP-03 terminals using Modbus RTU over TCP protocol|(% style="width:358px" %)
198 +|(((
199 +1.
200 +)))|(% style="width:214px" %)sed_rtu_over_tcp_kmp_rtd|(% style="width:676px" %)A service for polling Multitical 601 device using the KMP protocol|(% style="width:358px" %)sed_metrology_191.bin
201 +|(((
202 +1.
203 +)))|(% style="width:214px" %)sed_rtu_over_tcp_majac_arch|(% style="width:676px" %)A service for receiving archived data from devices using the Mayak protocol|(% style="width:358px" %)sed_metrology_152.bin
204 +|(((
205 +1.
206 +)))|(% style="width:214px" %)sed_rtu_over_tcp_mercury200_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the Mercury 200 protocol|(% style="width:358px" %)sed_metrology_251.bin
207 +|(((
208 +1.
209 +)))|(% style="width:214px" %)sed_rtu_over_tcp_mercury_arch|(% style="width:676px" %)A service for reading archives and event logs from Mercury-230 series devices using the Mercury-230 protocol|(% style="width:358px" %)sed_metrology_202.bin
210 +|(((
211 +1.
212 +)))|(% style="width:214px" %)sed_rtu_over_tcp_mercury_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the Mercury 230 protocol|(% style="width:358px" %)sed_metrology_201.bin
213 +|(((
214 +1.
215 +)))|(% style="width:214px" %)sed_rtu_over_tcp_photon_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the photon RTU over TCP protocol|(% style="width:358px" %)sed_metrology_221.bin
216 +|(((
217 +1.
218 +)))|(% style="width:214px" %)sed_rtu_over_tcp_ref542plus_waveform|(% style="width:676px" %)Proofreading of waveforms and time synchronization via Modbus RTU over TCP protocol from ABB REF 542plus devices|(% style="width:358px" %)
219 +|(((
220 +1.
221 +)))|(% style="width:214px" %)sed_rtu_over_tcp_set4tm_arch|(% style="width:676px" %)A service for polling SET-4TM, PSC meters’ archives|(% style="width:358px" %)sed_metrology_112.bin
222 +|(((
223 +1.
224 +)))|(% style="width:214px" %)sed_rtu_over_tcp_set4tm_rtd|(% style="width:676px" %)A service for receiving real-time data from devices using the SET-4TM rtu over tcp protocol|(% style="width:358px" %)sed_metrology_111.bin
225 +|(((
226 +1.
227 +)))|(% style="width:214px" %)sed_rtu_over_tcp_tem104_arch|(% style="width:676px" %)A service for receiving archived data from devices using the TEM104 protocol|(% style="width:358px" %)sed_metrology_162.bin
228 +|(((
229 +1.
230 +)))|(% style="width:214px" %)sed_rtu_over_tcp_tem104_rtd|(% style="width:676px" %)A service for receiving real-tume data from devices using the TEM104 protocol|(% style="width:358px" %)sed_metrology_161.bin
231 +|(((
232 +1.
233 +)))|(% style="width:214px" %)sed_rtu_over_tcp_vist_arch|(% style="width:676px" %)A service for receiving archived data from devices using the VIS.T protocol|(% style="width:358px" %)sed_metrology_172.bin
234 +|(((
235 +1.
236 +)))|(% style="width:214px" %)sed_rtu_over_tcp_vkt5_arch|(% style="width:676px" %)A service for receiving archived data from VKT-5 devices|(% style="width:358px" %)sed_metrology_312.bin
237 +|(((
238 +1.
239 +)))|(% style="width:214px" %)sed_rtu_over_tcp_vkt5_rtd|(% style="width:676px" %)A service for receiving real-time data from VKT-5 devices|(% style="width:358px" %)sed_metrology_311.bin
240 +|(((
241 +1.
242 +)))|(% style="width:214px" %)sed_vkt7_arch|(% style="width:676px" %)A service for receiving archived data from VKT-7 devices|(% style="width:358px" %)
243 +|(((
244 +1.
245 +)))|(% style="width:214px" %)sed_vkt7_rtd|(% style="width:676px" %)A service for receiving real-time data from VKT-7 devices|(% style="width:358px" %)
246 +|(((
247 +1.
248 +)))|(% style="width:214px" %)sed_rtu_over_tcp_vtd_arch|(% style="width:676px" %)A service for receiving archived data of VTD devices|(% style="width:358px" %)sed_metrology_182.bin
249 +|(((
250 +1.
251 +)))|(% style="width:214px" %)sed_rtu_over_tcp_vtd_rtd|(% style="width:676px" %)A service for receiving operational data from VTD devices|(% style="width:358px" %)sed_metrology_181.bin
252 +|(((
253 +1.
254 +)))|(% style="width:214px" %)sed_uvp_arch|(% style="width:676px" %)A service for poling Promavtomatika's archive for devices of the UVP series|(% style="width:358px" %)sed_metrology_352.bin
255 +|(((
256 +1.
257 +)))|(% style="width:214px" %)sed_ce_arch|(% style="width:676px" %)A service for receiving archived data from Energomera devices of the CE series according to the IEC61107 protocol|(% style="width:358px" %)sed_metrology_362.bin
258 +|(((
259 +1.
260 +)))|(% style="width:214px" %)sed_alpha_arch|(% style="width:676px" %)A service for receiving archived data from Alfa-3 devices manufactured by Alfamera|(% style="width:358px" %)sed_metrology_462_472.bin
261 +|(((
262 +1.
263 +)))|(% style="width:214px" %)sed_bug01_rtd|(% style="width:676px" %)A service for receiving archived data of BUG-01 devices|(% style="width:358px" %)sed_metrology_491.bin
264 +|(((
265 +1.
266 +)))|(% style="width:214px" %)sed_dymetic_arch|(% style="width:676px" %)A service for receiving archived data from Dimetik|(% style="width:358px" %)sed_metrology_552.bin
267 +|(((
268 +1.
269 +)))|(% style="width:214px" %)sed_irvis_arch|(% style="width:676px" %)A service for receiving archived data from devices using the Irvis protocol|(% style="width:358px" %)sed_metrology_442.bin
270 +|(((
271 +1.
272 +)))|(% style="width:214px" %)sed_karat_arch|(% style="width:676px" %)A service for receiving archived data from Karat devices|(% style="width:358px" %)sed_metrology_512.bin
273 +|(((
274 +1.
275 +)))|(% style="width:214px" %)sed_lis200_arch|(% style="width:676px" %)A service for receiving archived data from the EK-260 and EK-270 devices manufactured by Elster|(% style="width:358px" %)sed_metrology_452.bin
276 +|(((
277 +1.
278 +)))|(% style="width:214px" %)sed_rtu_over_tcp_sepam_waveform|(% style="width:676px" %)A service for reading waveform files from Sepam devices using Modbus RTU over TCP protocol|(% style="width:358px" %)sed_metrology_298.bin
279 +|(% colspan="4" %)**Data export and import services in SQL databases**
280 +|(((
281 +1.
282 +)))|(% style="width:214px" %)sed_sql_rtd|(% style="width:676px" %)A service for receiving tele-measurement data from MySQL|(% style="width:358px" %)sed_metrology_211.bin
283 +|(((
284 +1.
285 +)))|(% style="width:214px" %)sed_sql_arch|(% style="width:676px" %)A service for archived data retrieval from Microsoft SQL Server|(% style="width:358px" %)
286 +|(((
287 +1.
288 +)))|(% style="width:214px" %)sed_sql_arch_send|(% style="width:676px" %)A service for recording archived data in an external SQL database|(% style="width:358px" %)
289 +|(% colspan="4" %)**Data processing services**
290 +|(((
291 +1.
292 +)))|(% style="width:214px" %)sed_controller|(% style="width:676px" %)A service for telemetry reception and processing (writes to the InfluxDB database)|(% style="width:358px" %)sed_metrology_controller.bin
293 +|(((
294 +1.
295 +)))|(% style="width:214px" %)sed_events_calc|(% style="width:676px" %)A service for generating event based on the conditions specified in the configuration|(% style="width:358px" %)
296 +|(((
297 +1.
298 +)))|(% style="width:214px" %)sed_calc_arch|(% style="width:676px" %)A service for calculating metering channels|(% style="width:358px" %)(((
299 +sed_metrology_calc_arch.bin
300 +
301 +sed_metrology_formulas.bin
302 +)))
303 +|(((
304 +1.
305 +)))|(% style="width:214px" %)sed_calc_rtd|(% style="width:676px" %)A service for calculating pre-calculated tags|(% style="width:358px" %)
306 +|(((
307 +1.
308 +)))|(% style="width:214px" %)sed_round_arch|(% style="width:676px" %)A service for calculating metering channels with rounding|(% style="width:358px" %)sed_metrology_round_arch.bin
309 +|(((
310 +1.
311 +)))|(% style="width:214px" %)sed_energy_calc|(% style="width:676px" %)A service for server-level energy resource calculation|(% style="width:358px" %)sed_metrology_411_421.bin
312 +|(((
313 +1.
314 +)))|(% style="width:214px" %)sed_loadflow_calc|(% style="width:676px" %)A service for calculating modes based on an information model|(% style="width:358px" %)
315 +|(((
316 +1.
317 +)))|(% style="width:214px" %)sed_storage_writer|(% style="width:676px" %)A service for recording archived data (metering and event logs) in a data storage (InfluxDB and MongoDB)|(% style="width:358px" %)
318 +|(% colspan="4" %)**Web Part Services**
319 +|(((
320 +1.
321 +)))|(% style="width:214px" %)php5-cgi|(% style="width:676px" %)A Web Query Service|(% style="width:358px" %)
322 +|(((
323 +1.
324 +)))|(% style="width:214px" %)nginx|(% style="width:676px" %)A Web Server|(% style="width:358px" %)
325 +|(((
326 +1.
327 +)))|(% style="width:214px" %)sed_ui|(% style="width:676px" %)A service for processing requests for web resources (js, css, html files)|(% style="width:358px" %)
328 +|(((
329 +1.
330 +)))|(% style="width:214px" %)sed_rtd_analysis|(% style="width:676px" %)A service for analyzing real-time data|(% style="width:358px" %)
331 +|(((
332 +1.
333 +)))|(% style="width:214px" %)sed_auth|(% style="width:676px" %)A service for authenticating and authorizing users in the system and configuring access rights|(% style="width:358px" %)
334 +|(((
335 +1.
336 +)))|(% style="width:214px" %)sed_auth_privileges|(% style="width:676px" %)A User Privilege Management Service|(% style="width:358px" %)
337 +|(((
338 +1.
339 +)))|(% style="width:214px" %)sed_api_gateway|(% style="width:676px" %)A service for proxying of web requests to other services within the system|(% style="width:358px" %)
340 +|(((
341 +1.
342 +)))|(% style="width:214px" %)sed_dataset_configurator|(% style="width:676px" %)A service for working with datasets|(% style="width:358px" %)
343 +|(((
344 +1.
345 +)))|(% style="width:214px" %)sed_rtd|(% style="width:676px" %)A real-time data subscription service|(% style="width:358px" %)
346 +|(((
347 +1.
348 +)))|(% style="width:214px" %)sed_rtd_archive|(% style="width:676px" %)A service for generating archived data from real-time data|(% style="width:358px" %)
349 +|(((
350 +1.
351 +)))|(% style="width:214px" %)sed_system|(% style="width:676px" %)A service that provides a user interface with information about the system|(% style="width:358px" %)
352 +|(((
353 +1.
354 +)))|(% style="width:214px" %)sed_archive|(% style="width:676px" %)A service that provides user interfaces for analyzing electricity and energy accounting|(% style="width:358px" %)
355 +|(((
356 +1.
357 +)))|(% style="width:214px" %)sed_archive_integrity|(% style="width:676px" %)A service that provides user interfaces for analyzing the completeness of electricity and energy resources data|(% style="width:358px" %)
358 +|(((
359 +1.
360 +)))|(% style="width:214px" %)sed_pq_reports|(% style="width:676px" %)A service for working with power quality reports|(% style="width:358px" %)
361 +|(((
362 +1.
363 +)))|(% style="width:214px" %)sed_pq_journal|(% style="width:676px" %)A service for working with power quality logs|(% style="width:358px" %)
364 +|(((
365 +1.
366 +)))|(% style="width:214px" %)sed_ras_configurator|(% style="width:676px" %)A service for configuring emergency event loggers|(% style="width:358px" %)
367 +|(((
368 +1.
369 +)))|(% style="width:214px" %)sed_reports|(% style="width:676px" %)A service for generating and managing reports, and maintaining user interfaces for reports|(% style="width:358px" %)
370 +|(((
371 +1.
372 +)))|(% style="width:214px" %)sed_widgets|(% style="width:676px" %)A service for the user interfaces of drag'n'drop widgets|(% style="width:358px" %)
373 +|(((
374 +1.
375 +)))|(% style="width:214px" %)sed_menu|(% style="width:676px" %)A service for displaying and configuring CENTO system menu|(% style="width:358px" %)
376 +|(((
377 +1.
378 +)))|(% style="width:214px" %)sed_mnemonic_diagrams|(% style="width:676px" %)A service for the user interfaces of diagrams v2|(% style="width:358px" %)
379 +|(((
380 +1.
381 +)))|(% style="width:214px" %)sed_configuration|(% style="width:676px" %)A service for user interfaces for system configuration (alerts, mail servers, formulas, device trees)|(% style="width:358px" %)
382 +|(((
383 +1.
384 +)))|(% style="width:214px" %)sed_devices_configurator|(% style="width:676px" %)A service for editing device configurations, tags, and channels|(% style="width:358px" %)
385 +|(((
386 +1.
387 +)))|(% style="width:214px" %)sed_common_event_journal|(% style="width:676px" %)A service for user interfaces for generalized configurable event logs|(% style="width:358px" %)
388 +|(((
389 +1.
390 +)))|(% style="width:214px" %)sed_device_event_journal|(% style="width:676px" %)A Device Log Service|(% style="width:358px" %)
391 +|(((
392 +1.
393 +)))|(% style="width:214px" %)sed_operative_journal|(% style="width:676px" %)A service for the user interface of the real-time event log|(% style="width:358px" %)
394 +|(((
395 +1.
396 +)))|(% style="width:214px" %)sed_video_journal|(% style="width:676px" %)A Video Camera Log Service|(% style="width:358px" %)
397 +|(((
398 +1.
399 +)))|(% style="width:214px" %)sed_marking|(% style="width:676px" %)A Dispatch Tag Management Service|(% style="width:358px" %)
400 +|(((
401 +1.
402 +)))|(% style="width:214px" %)sed_sounds|(% style="width:676px" %)A service for the user interface for sound alerts management|(% style="width:358px" %)
403 +|(((
404 +1.
405 +)))|(% style="width:214px" %)sed_video_stream|(% style="width:676px" %)A service for streaming video from cameras registered in the information model|(% style="width:358px" %)
406 +|(% colspan="4" %)**System services**
407 +|(((
408 +1.
409 +)))|(% style="width:214px" %)nats|(% style="width:676px" %)A message broker and a service registry (service registry/service discovery)|(% style="width:358px" %)
410 +|(((
411 +1.
412 +)))|(% style="width:214px" %)influxdb|(% style="width:676px" %)A time series database|(% style="width:358px" %)
413 +|(((
414 +1.
415 +)))|(% style="width:214px" %)mongod|(% style="width:676px" %)A database of configuration and structured data (event logs, requests)|(% style="width:358px" %)
416 +|(((
417 +1.
418 +)))|(% style="width:214px" %)sed_signals|(% style="width:676px" %)A signal reception and transmission service inside the system (remote control, configuration update, manual polling, parameter recalculation)|(% style="width:358px" %)
419 +|(((
420 +1.
421 +)))|(% style="width:214px" %)sed_debug|(% style="width:676px" %)A service for providing access to debugging information of CENTO services|(% style="width:358px" %)
422 +|(((
423 +1.
424 +)))|(% style="width:214px" %)sed_graphql|(% style="width:676px" %)A subscription service for device statuses|(% style="width:358px" %)
425 +|(((
426 +1.
427 +)))|(% style="width:214px" %)sed_energy_calc_configuration|(% style="width:676px" %)A service for creating, changing, and deleting energy resource calculation configurations at the server level|(% style="width:358px" %)
428 +|(((
429 +1.
430 +)))|(% style="width:214px" %)sed_backup|(% style="width:676px" %)A service for backing up data according to the cron rule.|(% style="width:358px" %)
431 +|(((
432 +1.
433 +)))|(% style="width:214px" %)sed_channels|(% style="width:676px" %)A channel subscription service|(% style="width:358px" %)
434 +|(((
435 +1.
436 +)))|(% style="width:214px" %)sed_channels_data|(% style="width:676px" %)A subscription service for protocol statuses and the latest channel data|(% style="width:358px" %)
437 +|(((
438 +1.
439 +)))|(% style="width:214px" %)sed_emission_archive|(% style="width:676px" %)A service for providing emissions metering data|(% style="width:358px" %)
440 +|(((
441 +1.
442 +)))|(% style="width:214px" %)sed_profile_archive|(% style="width:676px" %)A service for providing metering data from InfluxDB via gRPC.|(% style="width:358px" %)
443 +|(((
444 +1.
445 +)))|(% style="width:214px" %)sed_web_storage|(% style="width:676px" %)A service for accessing archived metering data|(% style="width:358px" %)
446 +|(((
447 +1.
448 +)))|(% style="width:214px" %)sed_watchdog|(% style="width:676px" %)A service for managing the launch of CENTO services|(% style="width:358px" %)
449 +|(((
450 +1.
451 +)))|(% style="width:214px" %)sed_scheduler|(% style="width:676px" %)A service for launching scheduled tasks|(% style="width:358px" %)
452 +|(((
453 +1.
454 +)))|(% style="width:214px" %)sed_license|(% style="width:676px" %)A licensing service|(% style="width:358px" %)
455 +|(((
456 +1.
457 +)))|(% style="width:214px" %)sed_monitor|(% style="width:676px" %)A service for monitoring the operation of the system's services and applications|(% style="width:358px" %)
458 +|(((
459 +1.
460 +)))|(% style="width:214px" %)sed_telecontrol|(% style="width:676px" %)A remote control service|(% style="width:358px" %)
461 +|(((
462 +1.
463 +)))|(% style="width:214px" %)sed_notificator|(% style="width:676px" %)A service for notifying users about events by e-mail|(% style="width:358px" %)
464 +|(((
465 +1.
466 +)))|(% style="width:214px" %)sed_waveforms_journal|(% style="width:676px" %)A waveform Log Service|(% style="width:358px" %)
467 +|(((
468 +1.
469 +)))|(% style="width:214px" %)sed_storage_configurator|(% style="width:676px" %)An InfluxDB Database Configuration Service|(% style="width:358px" %)
470 +|(((
471 +1.
472 +)))|(% style="width:214px" %)sed_system_configuration|(% style="width:676px" %)A CENTO System Configuration Editing Service|(% style="width:358px" %)
473 +|(((
474 +1.
475 +)))|(% style="width:214px" %)sed_user_settings|(% style="width:676px" %)A User Settings Configuration Service|(% style="width:358px" %)
476 +|(((
477 +1.
478 +)))|(% style="width:214px" %)sed_system_event_journal|(% style="width:676px" %)A service for registration and provision of system events (business logic and administration)|(% style="width:358px" %)
479 +|(((
480 +1.
481 +)))|(% style="width:214px" %)sed_tech_event_journal|(% style="width:676px" %)A service for processing and managing technological events|(% style="width:358px" %)
482 +|(((
483 +1.
484 +)))|(% style="width:214px" %)sed_information_model|(% style="width:676px" %)A System Information Model Management Service|(% style="width:358px" %)
485 +|(((
486 +1.
487 +)))|(% style="width:214px" %)sed_events_configurator|(% style="width:676px" %)A System Event Configuration Service|(% style="width:358px" %)
488 +|(((
489 +1.
490 +)))|(% style="width:214px" %)sed_information_model_editor|(% style="width:676px" %)A service for editing the information model|(% style="width:358px" %)
491 +|(% colspan="4" %)**Server Backup Services**
492 +|(((
493 +1.
494 +)))|(% style="width:214px" %)sed_coordinator|(% style="width:676px" %)A service for selecting the cluster's host server using the Bully leader election algorithm|(% style="width:358px" %)
495 +|(((
496 +1.
497 +)))|(% style="width:214px" %)sed_reserve|(% style="width:676px" %)A service for displaying a list of backup servers|(% style="width:358px" %)
498 +|(((
499 +1.
500 +)))|(% style="width:214px" %)sed_replicator|(% style="width:676px" %)A log replication service between cluster servers|(% style="width:358px" %)
501 +|(((
502 +1.
503 +)))|(% style="width:214px" %)sed_influx_replicator|(% style="width:676px" %)A data replication service (archives and telemetry) between cluster servers|(% style="width:358px" %)
504 +|(((
505 +1.
506 +)))|(% style="width:214px" %)sed_events_replicator|(% style="width:676px" %)An event replication service between cluster servers|(% style="width:358px" %)
507 +|(((
508 +1.
509 +)))|(% style="width:214px" %)sed_fs_synch|(% style="width:676px" %)A data replication service (gob files, reports, waveforms) between cluster servers|(% style="width:358px" %)