Changes for page 2. Setup Manual
Last modified by Iaroslav Platonov on 2026/06/08 09:28
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.a dmin1 +XWiki.Lana - Content
-
... ... @@ -1,9 +1,10 @@ 1 ----- 2 - 1 +(% data-xwiki-rendering-protected="true" %) 3 3 = CONTENT = 4 4 5 5 {{toc/}} 6 6 6 +---- 7 + 7 7 = INTRODUCTION = 8 8 9 9 CENTO is a multifunctional software platform for data collection, processing, and display. ... ... @@ -466,7 +466,7 @@ 466 466 467 467 More detailed use of calculation channels is described in the "Guide to setting up accounting channels". 468 468 469 -= =CONFIGURING CENTO VIA EXCEL ==470 += CONFIGURING CENTO VIA EXCEL = 470 470 471 471 The CENTO software provides the ability to configure the system via Excel files. The interface of this functionality is located on the Downloading/Uploading Configuration Files page (Menu item "Settings" – "Configuration Files"). (see Fig. 3.1). 472 472 ... ... @@ -529,7 +529,7 @@ 529 529 530 530 "Tabular data references" are used in the mode calculation module, so their settings are specified in the "Mode Calculation Module Setup and Operation Manual". 531 531 532 -= =EVENTS ==533 += EVENTS = 533 533 534 534 "Events" in CENTO are designed to increase the observability of the system by tracking changes in the state of process equipment, recording changes in the event log and alerting users. 535 535 ... ... @@ -544,7 +544,7 @@ 544 544 * In the CENTO software, it is possible to notify users about the occurrence of events by e-mail in the "Notifications" menu item, the description and configuration of this functionality are described in the "Event System Configuration Guide". 545 545 * In the "Sound Editor" menu, it is possible to upload files for sound notification of the occurrence of an event, the setting is also indicated in the "Event System Setup Guide". 546 546 547 -= =MNEMONICS ==548 += MNEMONICS = 548 548 549 549 [[image:Screenshot 2025-11-09 at 22.13.04.png||height="403" width="658"]] 550 550 ... ... @@ -556,7 +556,7 @@ 556 556 557 557 More detailed use of mnemonic diagrams, their creation and configuration are described in the "Guide to the development of mnemonic diagrams". 558 558 559 -= =INFORMATION MODEL ==560 += INFORMATION MODEL = 560 560 561 561 An information model is a tool for describing the object of automation (physical objects, equipment, processes, etc.). The information model allows you to reflect the structure and consolidate information on each created object in the form of attributes (measurements, reference values, regulatory documentation, etc.). The information model is widely used in CENTO: to simplify the configuration of large systems, to implement various functions, to differentiate rights by objects. 562 562 ... ... @@ -570,7 +570,7 @@ 570 570 571 571 For a detailed description of how to set up an information model, see the Information Model Setup Guide. 572 572 573 -= =SYSTEM SETTINGS ==574 += SYSTEM SETTINGS = 574 574 575 575 [[image:Screenshot 2025-11-09 at 22.16.25.png]] 576 576 ... ... @@ -629,7 +629,7 @@ 629 629 630 630 To apply the changes, you need to refresh the browser page. 631 631 632 -= =TRANSFER KITS ==633 += TRANSFER KITS = 633 633 634 634 A number of methods are provided for the transfer of information (tags, channels) from CENTO to third-party systems: 635 635 ... ... @@ -648,7 +648,7 @@ 648 648 649 649 Fig.8.1 – Set Editor 650 650 651 -= =LIGHTING CONTROL ==652 += LIGHTING CONTROL = 652 652 653 653 [[image:Screenshot 2025-11-09 at 22.28.49.png||height="174" width="695"]] 654 654 ... ... @@ -656,7 +656,7 @@ 656 656 657 657 The "Lighting Control" page (see Fig. 9.1) ("Settings" - "Lighting Control") is used to enable/disable lighting objects from the "Lighting Control Module" schedule. The operation of this module is described in the "Lighting Control Module Setup Guide". 658 658 659 -= =TOOLING ==660 += TOOLING = 660 660 661 661 [[image:Screenshot 2025-11-09 at 22.29.51.png||height="354" width="291"]] 662 662 ... ... @@ -705,9 +705,9 @@ 705 705 706 706 The application is installed on the user's workplace. Allows you to work with CENTO without using a browser. After downloading the application for a certain type of operating system, it is necessary to run the file and enter the IP address of the server, after which the User gets to the authorization page, as without using this application. 707 707 708 -= =OTHER SETTINGS IN INTERFACES ==709 += OTHER SETTINGS IN INTERFACES = 709 709 710 -== =Analysis of real-time data ===711 +== Analysis of real-time data == 711 711 712 712 On the page "Analysis of operational data" ("Analysis" - "Operational data") there is a tab "Time" (Fig. 11.1), which is designed for time control on devices capable of transmitting their internal time to CENTO. In order for such devices to appear in the interface, time is collected from them into a tag with a name, for example, "Device time" in a string in the format YYYY-MM-DD HH:MM:SS. Next [[image:1762756612986-850.png||height="24" width="25"]] , the system will find all tags with this name and compare the time specified in them with the time of the last polling of the device. The difference will be displayed in the right column and will give the User an understanding of how many seconds the time of the device differs from the server time. 713 713 ... ... @@ -715,7 +715,7 @@ 715 715 716 716 Fig. 11.1 – Analysis of live data, "Time" tab 717 717 718 -== =Analysis of metering data ===719 +== Analysis of metering data == 719 719 720 720 On the page "Analysis of Metering data" ("Analysis" - "Metering Data"), in the Devices and Objects trees, it is possible to remove the tree levels (see Fig. 11.2) to display the path of the linked device in the table header (see Fig. 11.3) in the configuration window called by the button [[image:1762756705490-371.png||height="30" width="31"]] that is available to the User with the Administrator role. These settings are applied to all users. 721 721 ... ... @@ -727,7 +727,7 @@ 727 727 728 728 Fig. 11.3 – Display Tree Levels According to Setting 729 729 730 -== =Logs ===731 +== Logs == 731 731 732 732 In any event log ("Logs" - "Technological Events" - "Video Cameras" - "Oscillograms" - "Power Quality" - "Device Events" - System Events - "All Events") it is possible for the User with the Administrator role to change the width of columns by hovering over their borders and dragging them left/right. This appearance display will apply to all Users. 733 733 ... ... @@ -737,7 +737,7 @@ 737 737 738 738 Fig. 11.4 – Configure Log Display 739 739 740 -= =BASIC CONCEPTS AND ABBREVIATIONS ==741 += BASIC CONCEPTS AND ABBREVIATIONS = 741 741 742 742 DB – database; 743 743