Changes for page 2. Setup Manual
Last modified by Iaroslav Platonov on 2026/06/08 09:28
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -342,7 +342,7 @@ 342 342 343 343 The rules and specifics for setting up tags for different protocols and devices are described in separate configuration guides. 344 344 345 -=== 2.3.2.Add a calculation tag ===345 +=== Add a calculation tag === 346 346 347 347 If you select the "No log" item in the "Tag Polling Description" window (see Fig. 2.11) in the "Log" field, a calculated tag will be created, the value of which can be formed based on the transformation of other tags. 348 348 ... ... @@ -354,7 +354,7 @@ 354 354 355 355 Adding calculation tags to CENTO, as well as other configuration elements, is possible through the above-described web interface and using Excel files. Loading the CENTO configuration via Excel files is described in Section 3 of this guide. 356 356 357 -=== =2.3.3.Setting up calculation formulas ====357 +=== Setting up calculation formulas === 358 358 359 359 For calculated tags (see section 2.3.2), different processing formulas are used. If you use the same type of formulas for a number of tags, you should make a description of these formulas so that you can use them to process any required tag. 360 360 ... ... @@ -485,7 +485,7 @@ 485 485 where N is the serial number of the TI 486 486 )))|Previous Value of Telemeter from BDRV 487 487 488 -=== =2.3.4.Configuring calculation channels ====488 +=== Configuring calculation channels === 489 489 490 490 CENTO has the ability to create calculated accounting channels. A calculated channel can be created either based on the values of other channels or on the basis of tag values. In order to create a calculation channel, you need to go to the link "Settings" - "Devices, tags, channels" - "Calculation channels" (see Fig. 2.15). 491 491 ... ... @@ -509,7 +509,7 @@ 509 509 510 510 More detailed use of calculation channels is described in the "Guide to setting up accounting channels". 511 511 512 -= =3.CONFIGURING CENTO VIA EXCEL ==512 += CONFIGURING CENTO VIA EXCEL = 513 513 514 514 The CENTO software provides the ability to configure the system via Excel files. The interface of this functionality is located on the Downloading/Uploading Configuration Files page (Menu item "Settings" – "Configuration Files"). (see Fig. 3.1). 515 515 ... ... @@ -572,7 +572,7 @@ 572 572 573 573 "Tabular data references" are used in the mode calculation module, so their settings are specified in the "Mode Calculation Module Setup and Operation Manual". 574 574 575 -= =4.EVENTS ==575 += EVENTS = 576 576 577 577 "Events" in CENTO are designed to increase the observability of the system by tracking changes in the state of process equipment, recording changes in the event log and alerting users. 578 578 ... ... @@ -587,7 +587,7 @@ 587 587 * In the CENTO software, it is possible to notify users about the occurrence of events by e-mail in the "Notifications" menu item, the description and configuration of this functionality are described in the "Event System Configuration Guide". 588 588 * In the "Sound Editor" menu, it is possible to upload files for sound notification of the occurrence of an event, the setting is also indicated in the "Event System Setup Guide". 589 589 590 -= =5.MNEMONICS ==590 += MNEMONICS = 591 591 592 592 [[image:Screenshot 2025-11-09 at 22.13.04.png||height="403" width="658"]] 593 593 ... ... @@ -599,7 +599,7 @@ 599 599 600 600 More detailed use of mnemonic diagrams, their creation and configuration are described in the "Guide to the development of mnemonic diagrams". 601 601 602 -= =6.INFORMATION MODEL ==602 += INFORMATION MODEL = 603 603 604 604 An information model is a tool for describing the object of automation (physical objects, equipment, processes, etc.). The information model allows you to reflect the structure and consolidate information on each created object in the form of attributes (measurements, reference values, regulatory documentation, etc.). The information model is widely used in CENTO: to simplify the configuration of large systems, to implement various functions, to differentiate rights by objects. 605 605 ... ... @@ -613,7 +613,7 @@ 613 613 614 614 For a detailed description of how to set up an information model, see the Information Model Setup Guide. 615 615 616 -= =7.SYSTEM SETTINGS ==616 += SYSTEM SETTINGS = 617 617 618 618 [[image:Screenshot 2025-11-09 at 22.16.25.png]] 619 619 ... ... @@ -672,7 +672,7 @@ 672 672 673 673 To apply the changes, you need to refresh the browser page. 674 674 675 -= =8.TRANSFER KITS ==675 += TRANSFER KITS = 676 676 677 677 A number of methods are provided for the transfer of information (tags, channels) from CENTO to third-party systems: 678 678 ... ... @@ -691,7 +691,7 @@ 691 691 692 692 Fig.8.1 – Set Editor 693 693 694 -= =9.LIGHTING CONTROL ==694 += LIGHTING CONTROL = 695 695 696 696 [[image:Screenshot 2025-11-09 at 22.28.49.png||height="174" width="695"]] 697 697 ... ... @@ -699,7 +699,7 @@ 699 699 700 700 The "Lighting Control" page (see Fig. 9.1) ("Settings" - "Lighting Control") is used to enable/disable lighting objects from the "Lighting Control Module" schedule. The operation of this module is described in the "Lighting Control Module Setup Guide". 701 701 702 -= =10.TOOLING ==702 += TOOLING = 703 703 704 704 [[image:Screenshot 2025-11-09 at 22.29.51.png||height="354" width="291"]] 705 705 ... ... @@ -748,9 +748,9 @@ 748 748 749 749 The application is installed on the user's workplace. Allows you to work with CENTO without using a browser. After downloading the application for a certain type of operating system, it is necessary to run the file and enter the IP address of the server, after which the User gets to the authorization page, as without using this application. 750 750 751 -= =11.OTHER SETTINGS IN INTERFACES ==751 += OTHER SETTINGS IN INTERFACES = 752 752 753 -== =11.1.Analysis of real-time data ===753 +== Analysis of real-time data == 754 754 755 755 On the page "Analysis of operational data" ("Analysis" - "Operational data") there is a tab "Time" (Fig. 11.1), which is designed for time control on devices capable of transmitting their internal time to CENTO. In order for such devices to appear in the interface, time is collected from them into a tag with a name, for example, "Device time" in a string in the format YYYY-MM-DD HH:MM:SS. Next [[image:1762756612986-850.png||height="24" width="25"]] , the system will find all tags with this name and compare the time specified in them with the time of the last polling of the device. The difference will be displayed in the right column and will give the User an understanding of how many seconds the time of the device differs from the server time. 756 756 ... ... @@ -758,7 +758,7 @@ 758 758 759 759 Fig. 11.1 – Analysis of live data, "Time" tab 760 760 761 -== =11.2.Analysis of metering data ===761 +== Analysis of metering data == 762 762 763 763 On the page "Analysis of Metering data" ("Analysis" - "Metering Data"), in the Devices and Objects trees, it is possible to remove the tree levels (see Fig. 11.2) to display the path of the linked device in the table header (see Fig. 11.3) in the configuration window called by the button [[image:1762756705490-371.png||height="30" width="31"]] that is available to the User with the Administrator role. These settings are applied to all users. 764 764 ... ... @@ -770,7 +770,7 @@ 770 770 771 771 Fig. 11.3 – Display Tree Levels According to Setting 772 772 773 -== =11.3.Logs ===773 +== Logs == 774 774 775 775 In any event log ("Logs" - "Technological Events" - "Video Cameras" - "Oscillograms" - "Power Quality" - "Device Events" - System Events - "All Events") it is possible for the User with the Administrator role to change the width of columns by hovering over their borders and dragging them left/right. This appearance display will apply to all Users. 776 776 ... ... @@ -780,7 +780,7 @@ 780 780 781 781 Fig. 11.4 – Configure Log Display 782 782 783 -= =12.BASIC CONCEPTS AND ABBREVIATIONS ==783 += BASIC CONCEPTS AND ABBREVIATIONS = 784 784 785 785 DB – database; 786 786