Changes for page 2. Setup Manual

Last modified by Iaroslav Platonov on 2026/06/08 09:28

From version 152.8
edited by Lana
on 2025/11/11 16:54
Change comment: There is no comment for this version
To version 167.1
edited by admin
on 2025/11/13 09:21
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -Setup Guide
1 +2. Setup Manual
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Lana
1 +XWiki.admin
Content
... ... @@ -1,5 +1,8 @@
1 -== **CONTENT** ==
1 +(% data-xwiki-rendering-protected="true" %)
2 +{{toc/}}
2 2  
4 += **CONTENT** =
5 +
3 3  1. Introduction
4 4  
5 5  2. Devices, tags, channels
... ... @@ -42,20 +42,23 @@
42 42  
43 43   11.3. Logs
44 44  
48 +12. Basic concepts and abbreviations
45 45  
46 -== **1. INTRODUCTION** ==
50 +----
47 47  
52 += **INTRODUCTION** =
53 +
48 48  CENTO is a multifunctional software platform for data collection, processing, and display.
49 49  CENTO can be used to build various automated systems, for example: dispatching, control, accounting, diagnostics, etc.
50 50  This guide describes the general steps for setting up CENTO software, as well as links to other instructions.
51 51  
52 -== **2. DEVICES, TAGS, CHANNELS** ==
58 +== ** DEVICES, TAGS, CHANNELS** ==
53 53  
54 54  Operations for configuring the CENTO software are performed from the drop-down menu "Settings" (see Fig. 2.1) of the control panel at the top of the CENTO graphical interface.
55 55  \\[[image:1762536204394-536.png||height="430" width="212"]]
56 56  Fig. 2.1 – Settings drop-down menu
57 57  
58 -=== 2.1. Creating a device tree ===
64 +== Creating a device tree ==
59 59  
60 60  Configuration begins with the creation of a tree of devices (sources of information). The device tree is formed based on the convenience of further work with this tree and can reflect either the structure and names of the places where information sources are installed, or (in the case of small projects) combine information sources and production facilities of the enterprise.  This tree is necessary for the subsequent attribution of all sources of information and the information itself to this structure.
61 61  
... ... @@ -96,7 +96,7 @@
96 96  
97 97  Adding and configuring power facilities to CENTO is possible both through the above-described WEB-interface and using Excel files. Loading the CENTO configuration via Excel files is described in Section 3 of this guide.
98 98  
99 -=== 2.2. Creating devices ===
105 +== Creating devices ==
100 100  
101 101  You can create new devices (information sources) and edit existing ones on the "Devices, tags, channels" page ("Settings" – "Devices, tags, channels") (see Fig. 2.6).
102 102  
... ... @@ -195,7 +195,7 @@
195 195  |4|[[image:1762749353293-609.png]]|Tags or channels by device contain data with manual input
196 196  |9|[[image:1762749353294-893.png]]|Status Not Available (Status Not Yet Received or Not Available)
197 197  
198 -=== 2.3. Set up tags and channels ===
204 +== Set up tags and channels ==
199 199  
200 200  In CENTO software, information is divided into 2 types: tags and channels.
201 201  
... ... @@ -338,7 +338,7 @@
338 338  
339 339  The rules and specifics for setting up tags for different protocols and devices are described in separate configuration guides.
340 340  
341 -==== 2.3.2. Add a calculation tag ====
347 +=== Add a calculation tag ===
342 342  
343 343  If you select the "No log" item in the "Tag Polling Description" window (see Fig. 2.11) in the "Log" field, a calculated tag will be created, the value of which can be formed based on the transformation of other tags.
344 344  
... ... @@ -350,7 +350,7 @@
350 350  
351 351  Adding calculation tags to CENTO, as well as other configuration elements, is possible through the above-described web interface and using Excel files. Loading the CENTO configuration via Excel files is described in Section 3 of this guide.
352 352  
353 -==== 2.3.3. Setting up calculation formulas ====
359 +=== Setting up calculation formulas ===
354 354  
355 355  For calculated tags (see section 2.3.2), different processing formulas are used. If you use the same type of formulas for a number of tags, you should make a description of these formulas so that you can use them to process any required tag.
356 356  
... ... @@ -481,7 +481,7 @@
481 481  where N is the serial number of the TI
482 482  )))|Previous Value of Telemeter from BDRV
483 483  
484 -==== 2.3.4. Configuring calculation channels ====
490 +=== Configuring calculation channels ===
485 485  
486 486  CENTO has the ability to create calculated accounting channels. A calculated channel can be created either based on the values of other channels or on the basis of tag values. In order to create a calculation channel, you need to go to the link "Settings" - "Devices, tags, channels" - "Calculation channels" (see Fig. 2.15).
487 487  
... ... @@ -505,7 +505,7 @@
505 505  
506 506  More detailed use of calculation channels is described in the "Guide to setting up accounting channels".
507 507  
508 -== 3. CONFIGURING CENTO VIA EXCEL ==
514 += CONFIGURING CENTO VIA EXCEL =
509 509  
510 510  The CENTO software provides the ability to configure the system via Excel files. The interface of this functionality is located on the Downloading/Uploading Configuration Files page (Menu item "Settings" – "Configuration Files"). (see Fig. 3.1).
511 511  
... ... @@ -568,7 +568,7 @@
568 568  
569 569  "Tabular data references" are used in the mode calculation module, so their settings are specified in the "Mode Calculation Module Setup and Operation Manual".
570 570  
571 -== 4. EVENTS ==
577 += EVENTS =
572 572  
573 573  "Events" in CENTO are designed to increase the observability of the system by tracking changes in the state of process equipment, recording changes in the event log and alerting users.
574 574  
... ... @@ -583,7 +583,7 @@
583 583  * In the CENTO software, it is possible to notify users about the occurrence of events by e-mail in the "Notifications" menu item, the description and configuration of this functionality are described in the "Event System Configuration Guide".
584 584  * In the "Sound Editor" menu, it is possible to upload files for sound notification of the occurrence of an event, the setting is also indicated in the "Event System Setup Guide".
585 585  
586 -== 5. MNEMONICS ==
592 += MNEMONICS =
587 587  
588 588  [[image:Screenshot 2025-11-09 at 22.13.04.png||height="403" width="658"]]
589 589  
... ... @@ -595,7 +595,7 @@
595 595  
596 596  More detailed use of mnemonic diagrams, their creation and configuration are described in the "Guide to the development of mnemonic diagrams".
597 597  
598 -== 6. INFORMATION MODEL ==
604 += INFORMATION MODEL =
599 599  
600 600  An information model is a tool for describing the object of automation (physical objects, equipment, processes, etc.).  The information model allows you to reflect the structure and consolidate information on each created object in the form of attributes (measurements, reference values, regulatory documentation, etc.). The information model is widely used in CENTO: to simplify the configuration of large systems, to implement various functions, to differentiate rights by objects.
601 601  
... ... @@ -609,7 +609,7 @@
609 609  
610 610  For a detailed description of how to set up an information model, see the Information Model Setup Guide.
611 611  
612 -== 7. SYSTEM SETTINGS ==
618 += SYSTEM SETTINGS =
613 613  
614 614  [[image:Screenshot 2025-11-09 at 22.16.25.png]]
615 615  
... ... @@ -668,7 +668,7 @@
668 668  
669 669  To apply the changes, you need to refresh the browser page.
670 670  
671 -== 8. TRANSFER KITS ==
677 += TRANSFER KITS =
672 672  
673 673  A number of methods are provided for the transfer of information (tags, channels) from CENTO to third-party systems:
674 674  
... ... @@ -687,7 +687,7 @@
687 687  
688 688  Fig.8.1 – Set Editor
689 689  
690 -== 9. LIGHTING CONTROL ==
696 += LIGHTING CONTROL =
691 691  
692 692  [[image:Screenshot 2025-11-09 at 22.28.49.png||height="174" width="695"]]
693 693  
... ... @@ -695,7 +695,7 @@
695 695  
696 696  The "Lighting Control" page (see Fig. 9.1) ("Settings" - "Lighting Control") is used to enable/disable lighting objects from the "Lighting Control Module" schedule. The operation of this module is described in the "Lighting Control Module Setup Guide".
697 697  
698 -== 10. TOOLING ==
704 += TOOLING =
699 699  
700 700  [[image:Screenshot 2025-11-09 at 22.29.51.png||height="354" width="291"]]
701 701  
... ... @@ -744,9 +744,9 @@
744 744  
745 745  The application is installed on the user's workplace. Allows you to work with CENTO without using a browser. After downloading the application for a certain type of operating system, it is necessary to run the file and enter the IP address of the server, after which the User gets to the authorization page, as without using this application.
746 746  
747 -== 11. OTHER SETTINGS IN INTERFACES ==
753 += OTHER SETTINGS IN INTERFACES =
748 748  
749 -=== 11.1. Analysis of real-time data ===
755 +== Analysis of real-time data ==
750 750  
751 751  On the page "Analysis of operational data" ("Analysis" - "Operational data") there is a tab "Time" (Fig. 11.1), which is designed for time control on devices capable of transmitting their internal time to CENTO. In order for such devices to appear in the interface, time is collected from them into a tag with a name, for example, "Device time" in a string in the format YYYY-MM-DD HH:MM:SS.  Next [[image:1762756612986-850.png||height="24" width="25"]] , the system will find all tags with this name and compare the time specified in them with the time of the last polling of the device. The difference will be displayed in the right column and will give the User an understanding of how many seconds the time of the device differs from the server time.
752 752  
... ... @@ -754,7 +754,7 @@
754 754  
755 755  Fig. 11.1 – Analysis of live data, "Time" tab
756 756  
757 -=== 11.2. Analysis of metering data ===
763 +== Analysis of metering data ==
758 758  
759 759  On the page "Analysis of Metering data" ("Analysis" - "Metering Data"), in the Devices and Objects trees, it is possible to remove the tree levels (see Fig. 11.2) to display the path of the linked device in the table header (see Fig. 11.3) in the configuration window called by the button [[image:1762756705490-371.png||height="30" width="31"]] that is available to the User with the Administrator role. These settings are applied to all users.
760 760  
... ... @@ -766,7 +766,7 @@
766 766  
767 767  Fig. 11.3 – Display Tree Levels According to Setting
768 768  
769 -=== 11.3. Logs ===
775 +== Logs ==
770 770  
771 771  In any event log ("Logs" - "Technological Events" - "Video Cameras" - "Oscillograms" - "Power Quality" - "Device Events" - System Events - "All Events") it is possible for the User with the Administrator role to change the width of columns by hovering over their borders and dragging them left/right. This appearance display will apply to all Users.
772 772  
... ... @@ -776,7 +776,7 @@
776 776  
777 777  Fig. 11.4 – Configure Log Display
778 778  
779 -== BASIC CONCEPTS AND ABBREVIATIONS ==
785 += BASIC CONCEPTS AND ABBREVIATIONS =
780 780  
781 781  DB – database;
782 782  
noavatar.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +5.6 KB
Content
NumberedHeadings.Code.NumberedHeadingsClass[0]
Status
... ... @@ -1,0 +1,1 @@
1 +activated