Changes for page 2. Setup Manual
Last modified by Iaroslav Platonov on 2026/06/08 09:28
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,54 +1,5 @@ 1 - ==**CONTENT**==1 +**CONTENT** 2 2 3 -1. Introduction 4 - 5 -2. Devices, tags, channels 6 - 7 - 2.1. Creating a device tree 8 - 9 - 2.2. Creating devices 10 - 11 - 2.3. Set up tags and channels 12 - 13 - 2.3.1. Adding a protocol tag 14 - 15 - 2.3.2. Add a calculation tag 16 - 17 - 2.3.3. Setting up calculation formulas 18 - 19 - 2.3.4. Configuring calculation channels 20 - 21 -3. Configuring CENTO via Excel 22 - 23 -4. Events 24 - 25 -5. Mnemonics 26 - 27 -6. Information model 28 - 29 -7. System settings 30 - 31 -8. Transfer kits 32 - 33 -9. Lighting control 34 - 35 -10. Tooling 36 - 37 -~11. Other settings in interfaces 38 - 39 - 11.1. Analysis of real-time data 40 - 41 - 11.2. Analysis of metering data 42 - 43 - 11.3. Logs 44 - 45 - 46 - 47 -== == 48 - 49 - 50 - 51 - 52 52 == **1. INTRODUCTION** == 53 53 54 54 CENTO is a multifunctional software platform for data collection, processing, and display. ... ... @@ -687,47 +687,47 @@ 687 687 688 688 Data transfer via the OPC UA protocol and API does not require additional settings and is available after the installation of the appropriate modules in the system. 689 689 690 -Data transfer by other methods is carried out through the so-called Transmission Sets. Setting up Sets for transfer is located in the "Set Editor" (see Fig. 8.1) and the procedure for working with this interface is described in more detail in the "Guide to setting up sets for transmission".641 +Data transfer by other methods is carried out through the so-called Transmission Sets. Setting up Sets for transfer is located in the "Set Editor" (see Fig. 9.1) and the procedure for working with this interface is described in more detail in the "Guide to setting up sets for transmission". 691 691 692 692 [[image:Screenshot 2025-11-09 at 22.26.20.png||height="174" width="990"]] 693 693 694 -Fig. 8.1 – Set Editor645 +Fig.9.1 – Set Editor 695 695 696 696 == 9. LIGHTING CONTROL == 697 697 698 698 [[image:Screenshot 2025-11-09 at 22.28.49.png||height="174" width="695"]] 699 699 700 -Fig. 9.1 – Lighting control651 +Fig.10.1 – Lighting control 701 701 702 -The "Lighting Control" page (see Fig. 9.1) ("Settings" - "Lighting Control") is used to enable/disable lighting objects from the "Lighting Control Module" schedule. The operation of this module is described in the "Lighting Control Module Setup Guide".653 +The "Lighting Control" page (see Fig. 10.1) ("Settings" - "Lighting Control") is used to enable/disable lighting objects from the "Lighting Control Module" schedule. The operation of this module is described in the "Lighting Control Module Setup Guide". 703 703 704 704 == 10. TOOLING == 705 705 706 706 [[image:Screenshot 2025-11-09 at 22.29.51.png||height="354" width="291"]] 707 707 708 -Fig.1 0.1 – Tools menu659 +Fig.11.1 – Tools menu 709 709 710 -The CENTO software administrator has access to settings from the "Tools" menu item, as shown in Figure 1 0.1:661 +The CENTO software administrator has access to settings from the "Tools" menu item, as shown in Figure 11.1: 711 711 712 -**~1. Monitoring** – allows you to view the list of installed services in a tabular form (see Fig.1 0.2), there are filters in the Name and Status columns [[image:1762756224414-911.png]] , and sorting buttons in others [[image:1762756224415-121.png]] . Also, data on services can be viewed in a graphical representation on the tab [[image:1762756224415-521.png]] (see Fig.10.3). Data can be downloaded by clicking a button [[image:1762756224415-118.png||height="24" width="97"]] to a .xlsx file (see Fig.10.4), for a certain period of time selected in the calendar [[image:1762756224415-292.png||height="24" width="254"]]663 +**~1. Monitoring** – allows you to view the list of installed services in a tabular form (see Fig.11.2), there are filters in the Name and Status columns [[image:1762756224414-911.png]] , and sorting buttons in others [[image:1762756224415-121.png]] . Also, data on services can be viewed in a graphical representation on the tab [[image:1762756224415-521.png]] (see Fig.11.3). Data can be downloaded by clicking a button [[image:1762756224415-118.png||height="24" width="97"]] to a .xlsx file (see Fig.11.4), for a certain period of time selected in the calendar [[image:1762756224415-292.png||height="24" width="254"]] 713 713 714 714 [[image:Screenshot 2025-11-09 at 22.31.16.png]] 715 715 716 -Fig.1 0.2 – List of services in tabular form667 +Fig.11.2 – List of services in tabular form 717 717 718 718 [[image:Screenshot 2025-11-09 at 22.32.04.png]] 719 719 720 -Fig.1 0.3 – Service schedules671 +Fig.11.3 – Service schedules 721 721 722 722 [[image:Screenshot 2025-11-09 at 22.32.34.png||height="401" width="348"]] 723 723 724 -Fig.1 0.4 – Metrics in excel675 +Fig.11.4 – Metrics in excel 725 725 726 -In addition to information about the operation of services, in this interface ,you can view data on Users who use CENTO Software (see Fig. 10.5).677 +In addition to information about the operation of services, in this interface you can view data on Users who use CENTO Software (see Fig. 11.5). 727 727 728 728 [[image:Screenshot 2025-11-09 at 22.33.14.png]] 729 729 730 -Fig.1 0.5 – Users in CENTO software interfaces681 +Fig.11.5 – Users in CENTO software interfaces 731 731 732 732 This page displays information about Users who have used the CENTO software interfaces with the ability to search [[image:1762756421096-660.png]] by and sort [[image:1762756421096-718.png]] : 733 733 ... ... @@ -742,7 +742,7 @@ 742 742 743 743 **2. Server Reservation** – This item displays information about server reservations, the interface is described in the "Backup Guide". 744 744 745 -**3. Applications **—Provides access to additional applications that can be used on the system. This is currently the "CENTO Client" (see Figure 1 0.6)696 +**3. Applications **—Provides access to additional applications that can be used on the system. This is currently the "CENTO Client" (see Figure 11.6) 746 746 747 747 [[image:Screenshot 2025-11-09 at 22.34.57.png||height="254" width="627"]] 748 748