Changes for page 2. Setup Manual

Last modified by Iaroslav Platonov on 2026/06/08 09:28

From version 123.2
edited by Lana
on 2025/11/10 01:25
Change comment: There is no comment for this version
To version 126.2
edited by Lana
on 2025/11/10 01:28
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -610,7 +610,7 @@
610 610  
611 611  * change the language of the system (see Fig.7.5) After changing the language, the language in the CENTO interfaces will be changed (except for the information entered by the user himself when configuring the system, for example: names of devices, tags, symbols on mnemonic circuits, etc.)
612 612  
613 -[[image:Screenshot 2025-11-09 at 22.23.20.png||height="200" width="908"]]
613 +[[image:Screenshot 2025-11-09 at 22.23.20.png||height="214" width="972"]]
614 614  
615 615  Fig.7.5 – Selection of the system language
616 616  
... ... @@ -617,7 +617,7 @@
617 617  * server redundancy and backup of configuration/live data of tags and accounting channels/logs/reports (see "Backup Guide");
618 618  * To change the row height for all tables in the CENTO interfaces, see Figure 7.6:
619 619  
620 -[[image:Screenshot 2025-11-09 at 22.24.28.png||height="202" width="906"]]
620 +[[image:Screenshot 2025-11-09 at 22.24.28.png||height="217" width="974"]]
621 621  
622 622  Fig.7.6 – Adjusting rows in interface tables
623 623  
... ... @@ -625,4 +625,25 @@
625 625  
626 626  To apply the changes, you need to refresh the browser page.
627 627  
628 -
628 +== 8. TRANSFER KITS ==
629 +
630 +A number of methods are provided for the transfer of information (tags, channels) from CENTO to third-party systems:
631 +
632 +* Transmission via IEC-60870-5-104 protocol (tags);
633 +* Transmission via MODBUS TCP (tags);
634 +* Transfer to third-party MS SQL or MySQL databases (channels);
635 +* Transmission of electricity metering data in the form of XML files (channels);
636 +* Transmission via the OPC UA protocol (tags, channels);
637 +* Transfer via API (tags, channels, device trees, objects, information model attributes, etc.)
638 +
639 +Data transfer via the OPC UA protocol and API does not require additional settings and is available after the installation of the appropriate modules in the system.
640 +
641 +Data transfer by other methods is carried out through the so-called Transmission Sets. Setting up Sets for transfer is located in the "Set Editor" (see Fig. 9.1) and the procedure for working with this interface is described in more detail in the "Guide to setting up sets for transmission".
642 +
643 +[[image:Screenshot 2025-11-09 at 22.26.20.png||height="174" width="990"]]
644 +
645 +Fig.9.1 – Set Editor
646 +
647 +== 9. LIGHTING CONTROL ==
648 +
649 +[[image:Screenshot 2025-11-09 at 22.28.49.png]]
Screenshot 2025-11-09 at 22.26.20.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +49.4 KB
Content
Screenshot 2025-11-09 at 22.28.49.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +27.0 KB
Content