Changes for page 2. Setup Manual
Last modified by Iaroslav Platonov on 2026/06/08 09:28
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -604,9 +604,42 @@ 604 604 605 605 * depth of storage of tag values/flexible reports/system log/technological log (see Fig. 7.4), after the expiration of the depth period, the data will be deleted from the database: 606 606 607 -[[image:Screenshot 2025-11-09 at 22.22.12.png||height="2 63" width="687"]]607 +[[image:Screenshot 2025-11-09 at 22.22.12.png||height="242" width="632"]] 608 608 609 609 Fig.7.4 – Setting the storage depth 610 610 611 -* change the language of the system (see Fig.7.5) After changing the language, the language in the CENTO interfaces will be changed (except for the information entered by the user himself when configuring the system, for example: names of devices, tags, symbols on mnemonic circuits, etc.). 612 -* 611 +* change the language of the system (see Fig.7.5) After changing the language, the language in the CENTO interfaces will be changed (except for the information entered by the user himself when configuring the system, for example: names of devices, tags, symbols on mnemonic circuits, etc.) 612 + 613 +[[image:Screenshot 2025-11-09 at 22.23.20.png||height="200" width="908"]] 614 + 615 +Fig.7.5 – Selection of the system language 616 + 617 +* server redundancy and backup of configuration/live data of tags and accounting channels/logs/reports (see "Backup Guide"); 618 +* To change the row height for all tables in the CENTO interfaces, see Figure 7.6: 619 + 620 +[[image:Screenshot 2025-11-09 at 22.24.28.png||height="202" width="906"]] 621 + 622 +Fig.7.6 – Adjusting rows in interface tables 623 + 624 +* Changing the start page of the system. 625 + 626 +To apply the changes, you need to refresh the browser page. 627 + 628 +== 8. TRANSFER KITS == 629 + 630 +A number of methods are provided for the transfer of information (tags, channels) from CENTO to third-party systems: 631 + 632 +* Transmission via IEC-60870-5-104 protocol (tags); 633 +* Transmission via MODBUS TCP (tags); 634 +* Transfer to third-party MS SQL or MySQL databases (channels); 635 +* Transmission of electricity metering data in the form of XML files (channels); 636 +* Transmission via the OPC UA protocol (tags, channels); 637 +* Transfer via API (tags, channels, device trees, objects, information model attributes, etc.) 638 + 639 +Data transfer via the OPC UA protocol and API does not require additional settings and is available after the installation of the appropriate modules in the system. 640 + 641 +Data transfer by other methods is carried out through the so-called Transmission Sets. Setting up Sets for transfer is located in the "Set Editor" (see Fig. 9.1) and the procedure for working with this interface is described in more detail in the "Guide to setting up sets for transmission". 642 + 643 +[[image:Screenshot 2025-11-09 at 22.26.20.png]] 644 + 645 +
- Screenshot 2025-11-09 at 22.24.28.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Lana - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.1 KB - Content
- Screenshot 2025-11-09 at 22.26.20.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Lana - Size
-
... ... @@ -1,0 +1,1 @@ 1 +49.4 KB - Content