Changes for page 5. Diagrams Development Manual
Last modified by Iaroslav Platonov on 2026/06/08 10:32
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,5 @@ 1 1 = CONTENT = 2 2 3 -{{toc/}} 4 - 5 5 = 1. INTRODUCTION = 6 6 7 7 CENTO is a multifunctional software platform for data collection, processing, and display. ... ... @@ -360,13 +360,13 @@ 360 360 361 361 If the objects on the diagram differ from those placed in the category, clicking **Select all similar elements** pops up a message as in Fig. 4.14. 362 362 363 -[[image:Screenshot 2025-12-04 at 13.11.47.png ||height="504" width="369"]]361 +[[image:Screenshot 2025-12-04 at 13.11.47.png]] 364 364 365 365 Figure 4.14. Selecting similar elements is not available 366 366 367 367 == 4.6. Auto-replace of colors used in diagrams == 368 368 369 -[[image:Screenshot 2025-12-04 at 13.12.37.png ||height="408" width="581"]]367 +[[image:Screenshot 2025-12-04 at 13.12.37.png]] 370 370 371 371 Figure 4.15. Color replacement modal window 372 372 ... ... @@ -374,7 +374,7 @@ 374 374 375 375 == 4.7. Setting up an animation frame for technological events associated with a diagram object == 376 376 377 -[[image:Screenshot 2025-12-04 at 13.13.43.png ||height="311" width="582"]]375 +[[image:Screenshot 2025-12-04 at 13.13.43.png]] 378 378 379 379 Figure 4.16. Scheme settings modal window 380 380 ... ... @@ -393,7 +393,7 @@ 393 393 394 394 The default chart template is in a custom category named **Charts.** To use it, move it to the diagram canvas (see Fig. 4.17). 395 395 396 -[[image:Screenshot 2025-12-04 at 13.15.15.png ||height="291" width="582"]]394 +[[image:Screenshot 2025-12-04 at 13.15.15.png]] 397 397 398 398 Figure 4.17. Charts object 399 399 ... ... @@ -405,7 +405,7 @@ 405 405 406 406 Fig. 4.18 shows an example of configuring the tag value chart display 407 407 408 -[[image:Screenshot 2025-12-04 at 13.16.36.png ||height="532" width="452"]]406 +[[image:Screenshot 2025-12-04 at 13.16.36.png]] 409 409 410 410 Figure 4.18. Edit data of chart modal window 411 411 ... ... @@ -424,7 +424,7 @@ 424 424 425 425 When filling in the chart settings, the data is displayed as shown below: 426 426 427 -[[image:Screenshot 2025-12-04 at 13.18.01.png ||height="269" width="559"]]425 +[[image:Screenshot 2025-12-04 at 13.18.01.png]] 428 428 429 429 Figure 4.19. Chart in the diagram viewer 430 430 ... ... @@ -432,7 +432,7 @@ 432 432 433 433 === 4.8.2. Charts of tag values selected on the diagram === 434 434 435 -[[image:Screenshot 2025-12-04 at 13.18.57.png ||height="599" width="559"]]433 +[[image:Screenshot 2025-12-04 at 13.18.57.png]] 436 436 437 437 Figure 4.20. Edit the data of the chart 438 438 ... ... @@ -449,13 +449,13 @@ 449 449 450 450 When the chart settings are configured as shown in Fig. 4.20, data in view mode is displayed only after a linked tag is left-clicked. Each additional selected tag plots its own chart (see Fig. 4.21). 451 451 452 -[[image:Screenshot 2025-12-04 at 13.19.47.png ||height="257" width="551"]]450 +[[image:Screenshot 2025-12-04 at 13.19.47.png]] 453 453 454 454 Figure 4.21. Chart in the diagram viewer 455 455 456 456 === 4.8.3. Displaying future data on charts === 457 457 458 -[[image:Screenshot 2025-12-04 at 13.20.34.png ||height="467" width="359"]]456 +[[image:Screenshot 2025-12-04 at 13.20.34.png]] 459 459 460 460 Figure 4.22. Edit the data of the chart 461 461 ... ... @@ -716,7 +716,7 @@ 716 716 717 717 Figure 4.49. Displaying a number in exponential form 718 718 719 -== 4.17. Displaying delimited values == 717 +== 4.17. Displaying delimited values == 720 720 721 721 In the settings [[image:Screenshot 2025-12-04 at 13.50.03.png]] , in diagram view mode, instant tag values can be displayed as delimited values. This setting is enabled by default (see Fig. 4.50). 722 722 ... ... @@ -765,7 +765,7 @@ 765 765 * **Width **is the column width. 766 766 * **Change time **is a system field used to display the time of the metering channel's value change. 767 767 768 -Rows in this table can be moved [[image:Screenshot 2025-12-04 at 14.08.30.png]], deleted [[image:Screenshot 2025-12-04 at 14.09.56.png||height="32" width="33"]], and added [[image:Screenshot 2025-12-04 at 14.10.25.png||height="31" width="89"]]. 766 +Rows in this table can be moved [[image:Screenshot 2025-12-04 at 14.08.30.png]], deleted [[image:Screenshot 2025-12-04 at 14.09.56.png||height="32" width="33"]], and added [[image:Screenshot 2025-12-04 at 14.10.25.png||height="31" width="89"]]. 769 769 770 770 [[image:Screenshot 2025-12-04 at 14.10.47.png]] 771 771 ... ... @@ -827,7 +827,7 @@ 827 827 1. Blocking changes to a layer from the list. 828 828 1. Foreground/background of the layer. 829 829 830 -== 4.21. Active SVG elements == 828 +== 4.21. Active SVG elements == 831 831 832 832 The diagram editor allows importing graphic element templates in SVG format from various sources. Developed animated images from external sources help optimize work in both view and edit modes of the diagram (see Section 4.22.1). They also enable monitoring technological processes with the ability to view moving and rotating objects on the diagram (see Section 4.22.2). 833 833 ... ... @@ -1048,173 +1048,12 @@ 1048 1048 1049 1049 Select the text on the diagram, which is to be a dynamic parameter, and open the window [[image:Screenshot 2025-12-04 at 14.39.54.png||height="28" width="29"]]. 1050 1050 1051 -In the rule, check the box next to the words** Without conditions** (1) (optional) and describe the first action. Mark the**Text** field, select the **Tag** parameter type (2) and write, for example, the ID=502001 (3) number from the database (or select it from the drop-down list (4) see Fig. 5.2), if it is necessary to round the values, enable rounding (5) and specify how many decimal places should be displayed. It is possible to format the text in the actions of the rules (6) (see Fig. 5.3), as well as output the value of the number in exponential form (7). Click **Save,** switch to the diagram [[image:Screenshot 2025-12-04 at 14.40.43.png||height="24" width="31"]]viewing mode and see the result (see Fig. 5.4).1049 +In the rule, check the box next to the words** Without conditions** (1) (optional) and describe the first action. Mark the** Text** field, select the **Tag** parameter type (2) and write, for example, the ID=502001 (3) number from the database (or select it from the drop-down list (4) see Fig. 5.2), if it is necessary to round the values, enable rounding (5) and specify how many decimal places should be displayed. It is possible to format the text in the actions of the rules (6) (see Fig. 5.3), as well as output the value of the number in exponential form (7). Click **Save,** switch to the diagram [[image:Screenshot 2025-12-04 at 14.40.43.png||height="24" width="31"]]viewing mode and see the result (see Fig. 5.4). 1052 1052 1053 1053 [[image:Screenshot 2025-12-04 at 14.41.18.png]] 1054 1054 1055 1055 Figure 5.1. Binding to the text 1056 1056 1057 -To quickly bind to a tag, the **Component visual settings** window can be skipped by using the **Bind an element to a tag or channel** tree [[image:Screenshot 2025-12-04 at 14.41.48.png ||height="25" width="25"]]. This automatically fills the tag, see Fig. 5.1.1055 +To quickly bind to a tag, the **Component visual settings** window can be skipped by using the **Bind an element to a tag or channel** tree [[image:Screenshot 2025-12-04 at 14.41.48.png]]. This automatically fills the tag, see Fig. 5.1. 1058 1058 1059 -[[image:Screenshot 2025-12-04 at 14.42.21.png]] 1060 - 1061 -Figure 5.2. Choose the parameter drop-down list 1062 - 1063 -[[image:Screenshot 2025-12-04 at 14.42.51.png]] 1064 - 1065 -Figure 5.3. Formatting the text in the rules 1066 - 1067 -[[image:Screenshot 2025-12-04 at 14.43.17.png]] 1068 - 1069 -Figure 5.4. Tag value in the view mode 1070 - 1071 -The tag settings include a field not only for the ID number but also for specifying a code that can be used when binding to the diagram. To do this, in Fig. 5.1, field No. 3, enter the tag code instead of its ID. 1072 - 1073 -In the viewing mode in Fig. 5.4 there is no difference in the display in this case. 1074 - 1075 -**Example No. 2** 1076 - 1077 -An example of binding a real parameter taken from a database, which outputs information on a diagram in the form of a dynamic element that changes color depending on the incoming value and the status of the parameter. 1078 - 1079 -CENTO receives various tag statuses: 1080 - 1081 -[[image:Screenshot 2025-12-04 at 14.44.04.png||height="421" width="343"]] 1082 - 1083 -Figure 5.5. Tag statuses 1084 - 1085 -For example, two statuses can be used: when the telemeasurment TI value is received in real time (i.e., 1 – Normal), and when the telemeasurment TI value is entered manually by the user (i.e., 4 – Manual input). 1086 - 1087 -Real parameter data for binding: 1088 - 1089 -|**ID number**|**Parameter name**|**Values**|**Decryption** 1090 -|10154|Emergency alarm (EA)|0/1|((( 1091 -normal/ 1092 - 1093 -trigerring 1094 -))) 1095 - 1096 -Create a rectangle (with or without fill) and write the text //AC// inside the stroke. 1097 - 1098 -This element changes the background color depending on the incoming value and the status of the parameter, if the condition TI=0 is met, then the color is green, if the condition TI=1 is met, then the color is red, if there is no data, then the color is white (see Fig. 5.6). 1099 - 1100 -[[image:Screenshot 2025-12-04 at 14.45.25.png]] 1101 - 1102 -Figure 5.6. Color changing in a dynamic element 1103 - 1104 -To do this, select the created rectangle with left-clicking and open the bindings window [[image:Screenshot 2025-12-04 at 14.45.55.png||height="25" width="28"]] 1105 - 1106 -Create the following rules: 1107 - 1108 -Rule No. 1 (fill in green with the value of TI = 0): 1109 - 1110 -If the TI value is 0 (normal), then the background is green (see Fig. 5.7). 1111 - 1112 -Rule No. 2 (fill in red with the value of TI = 1): 1113 - 1114 -If the TI value is 1 (signal available, then the background is red (see Fig. 5.8). 1115 - 1116 -Rule No. 3 (fill in white when the T is not equal to 0 and not equal to 1): 1117 - 1118 -If the TI value is not equal to 0 and at the same time the TI value is not equal to 1, then the background is white (see Fig. 5.9). 1119 - 1120 -Rule No. 4 (fill in white if the status is not normal and not with manual input): 1121 - 1122 -If the TI status is not equal to 1 (normal) and at the same time the TI status is not equal to 4 (not manual input), then the background is white (see Fig. 5.10). 1123 - 1124 -[[image:Screenshot 2025-12-04 at 14.46.37.png]] 1125 - 1126 -Figure 5.7. Rule No. 1 1127 - 1128 -[[image:Screenshot 2025-12-04 at 14.46.57.png]] 1129 - 1130 -Figure 5.8. Rule No. 2 1131 - 1132 -[[image:Screenshot 2025-12-04 at 14.47.27.png]] 1133 - 1134 -Figure 5.9. Rule No. 3 1135 - 1136 -[[image:Screenshot 2025-12-04 at 14.47.57.png]] 1137 - 1138 -Figure 5.10. Rule No. 4 1139 - 1140 -== 5.2. Binding devices to the diagram == 1141 - 1142 -There are several device status values: 1143 - 1144 -0 – Disabled, 1145 - 1146 -1 – Normal, 1147 - 1148 -2 – Device has data errors, 1149 - 1150 -3 – Device is unavailable, 1151 - 1152 -4 – Data with manual input available, 1153 - 1154 -7 – Waiting for data, 1155 - 1156 -9 – Status is missing. 1157 - 1158 - The device is bound to the diagram by selecting **Device status** from the menu item. The content of the rules is similar to the example described above with changing the color of an object (in the** Condition** field, select the desired type of parameter, specify the device address, specify the operator and enter a numeric value equal to one or another status, and then specify the **Action **to be applied to the condition being fulfilled, for example, see Fig. 5.11). 1159 - 1160 -[[image:Screenshot 2025-12-04 at 14.49.03.png]] 1161 - 1162 -Figure 5.11. Binding to the device status 1163 - 1164 -Additionally, when using a template with a set of rules, device binding can be performed through the device tree by clicking on [[image:Screenshot 2025-12-04 at 14.49.33.png||height="24" width="25"]]. This automatically fills in the device ID fields shown in Fig. 5.11 streamlining the debugging process without opening the rules window. 1165 - 1166 -== 5.3. Binding parameters to information model objects == 1167 - 1168 -To create an information model, see the "Information model setup manual". 1169 - 1170 -For example, create a square element (to serve as a switch) and describe the rules for it. In this example, the square changes the background color depending on the incoming parameter of the information model object, which refers to the value from the CENTO database. 1171 - 1172 -The sequence of bindings to the parameters of an information model object is like the actions for binding to tags: instead of **Tag value** and **Tag status,** select the** IM attribute** and **IM parameter status**, see Fig. 5.12. 1173 - 1174 -[[image:Screenshot 2025-12-04 at 14.50.40.png]] 1175 - 1176 -Figure 5.12. Binding to the parameter of the information model object 1177 - 1178 -In this example, the address of the parameter is the information model class, and its attribute is selected when opening the drop-down list [[image:Screenshot 2025-12-04 at 14.51.19.png||height="35" width="28"]], see Fig. 5.13. 1179 - 1180 -[[image:Screenshot 2025-12-04 at 14.51.50.png]] 1181 - 1182 -Figure 5.13. Window with IM classes and their attributes 1183 - 1184 -After assembling the shape with the necessary rules for dynamic display, select the entire group and click the left mouse button. In the drop-down window, select **Create active element**, see Fig. 5.14. This function also applies to individual graphic drawings. To bind to the information model, open the appropriate bindings menu [[image:Screenshot 2025-12-04 at 14.52.28.png||height="31" width="31"]]. 1185 - 1186 -[[image:Screenshot 2025-12-04 at 14.52.56.png]] 1187 - 1188 -Figure 5.14. Creating an active element 1189 - 1190 -After creating the active element, the settings shown in Fig. 5.15 become the default. To set properties, right-click on the active element and select **Edit data of element** from the menu. 1191 - 1192 -[[image:Screenshot 2025-12-04 at 14.53.33.png]] 1193 - 1194 -Figure 5.15. Edit the data of elements 1195 - 1196 -After setting up the properties, select the shape and click the button [[image:Screenshot 2025-12-04 at 14.54.04.png||height="27" width="26"]]. Find the necessary element in the tree and select it (see Fig. 5.16). 1197 - 1198 -[[image:Screenshot 2025-12-04 at 14.54.49.png]] 1199 - 1200 -Figure 5.16. Information model element binding 1201 - 1202 -In this way, it is bound to the elements of the information model. When switching from the editor to the diagram viewing mode and right-clicking on the created shape, the **Measurements** context menu appears, showing the complete set of parameters described in the information model, as shown in Fig. 3.3. 1203 - 1204 -Right-clicking displays a table of parameters, which includes all the parameters from measurements, with the option to configure short tag names and decode values, as shown in Fig. 5.17. 1205 - 1206 -[[image:Screenshot 2025-12-04 at 14.55.22.png]] 1207 - 1208 -Figure 5.17. Table of the IM element parameters 1209 - 1210 -This object also has the option to display posters, with their arrangement appearing as shown in Fig. 5.18. 1211 - 1212 -[[image:Screenshot 2025-12-04 at 14.55.48.png]] 1213 - 1214 -Figure 5.18. Installation of customized posters 1215 - 1216 -= ABBREVIATIONS = 1217 - 1218 -DB – the database 1219 - 1220 -IM – information model. 1057 +