Changes for page 5. Diagrams Development Manual
Last modified by Iaroslav Platonov on 2026/06/08 10:32
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,7 @@ 1 1 = CONTENT = 2 2 3 +{{toc/}} 4 + 3 3 = 1. INTRODUCTION = 4 4 5 5 CENTO is a multifunctional software platform for data collection, processing, and display. ... ... @@ -358,13 +358,13 @@ 358 358 359 359 If the objects on the diagram differ from those placed in the category, clicking **Select all similar elements** pops up a message as in Fig. 4.14. 360 360 361 -[[image:Screenshot 2025-12-04 at 13.11.47.png]] 363 +[[image:Screenshot 2025-12-04 at 13.11.47.png||height="504" width="369"]] 362 362 363 363 Figure 4.14. Selecting similar elements is not available 364 364 365 365 == 4.6. Auto-replace of colors used in diagrams == 366 366 367 -[[image:Screenshot 2025-12-04 at 13.12.37.png]] 369 +[[image:Screenshot 2025-12-04 at 13.12.37.png||height="408" width="581"]] 368 368 369 369 Figure 4.15. Color replacement modal window 370 370 ... ... @@ -372,7 +372,7 @@ 372 372 373 373 == 4.7. Setting up an animation frame for technological events associated with a diagram object == 374 374 375 -[[image:Screenshot 2025-12-04 at 13.13.43.png]] 377 +[[image:Screenshot 2025-12-04 at 13.13.43.png||height="311" width="582"]] 376 376 377 377 Figure 4.16. Scheme settings modal window 378 378 ... ... @@ -391,7 +391,7 @@ 391 391 392 392 The default chart template is in a custom category named **Charts.** To use it, move it to the diagram canvas (see Fig. 4.17). 393 393 394 -[[image:Screenshot 2025-12-04 at 13.15.15.png]] 396 +[[image:Screenshot 2025-12-04 at 13.15.15.png||height="291" width="582"]] 395 395 396 396 Figure 4.17. Charts object 397 397 ... ... @@ -403,7 +403,7 @@ 403 403 404 404 Fig. 4.18 shows an example of configuring the tag value chart display 405 405 406 -[[image:Screenshot 2025-12-04 at 13.16.36.png]] 408 +[[image:Screenshot 2025-12-04 at 13.16.36.png||height="532" width="452"]] 407 407 408 408 Figure 4.18. Edit data of chart modal window 409 409 ... ... @@ -422,7 +422,7 @@ 422 422 423 423 When filling in the chart settings, the data is displayed as shown below: 424 424 425 -[[image:Screenshot 2025-12-04 at 13.18.01.png]] 427 +[[image:Screenshot 2025-12-04 at 13.18.01.png||height="269" width="559"]] 426 426 427 427 Figure 4.19. Chart in the diagram viewer 428 428 ... ... @@ -430,7 +430,7 @@ 430 430 431 431 === 4.8.2. Charts of tag values selected on the diagram === 432 432 433 -[[image:Screenshot 2025-12-04 at 13.18.57.png]] 435 +[[image:Screenshot 2025-12-04 at 13.18.57.png||height="599" width="559"]] 434 434 435 435 Figure 4.20. Edit the data of the chart 436 436 ... ... @@ -447,13 +447,13 @@ 447 447 448 448 When the chart settings are configured as shown in Fig. 4.20, data in view mode is displayed only after a linked tag is left-clicked. Each additional selected tag plots its own chart (see Fig. 4.21). 449 449 450 -[[image:Screenshot 2025-12-04 at 13.19.47.png]] 452 +[[image:Screenshot 2025-12-04 at 13.19.47.png||height="257" width="551"]] 451 451 452 452 Figure 4.21. Chart in the diagram viewer 453 453 454 454 === 4.8.3. Displaying future data on charts === 455 455 456 -[[image:Screenshot 2025-12-04 at 13.20.34.png]] 458 +[[image:Screenshot 2025-12-04 at 13.20.34.png||height="502" width="386"]] 457 457 458 458 Figure 4.22. Edit the data of the chart 459 459 ... ... @@ -467,13 +467,13 @@ 467 467 468 468 This data, displayed on the charts, enables forecasting, comparing planned vs. actual performance at the enterprise, and similar analyses. 469 469 470 -[[image:Screenshot 2025-12-04 at 13.21.50.png]] 472 +[[image:Screenshot 2025-12-04 at 13.21.50.png||height="262" width="548"]] 471 471 472 472 Figure 4.23. Forecasting chart 473 473 474 474 == 4.9. Setting up level indicators == 475 475 476 -[[image:Screenshot 2025-12-04 at 13.23.18.png]] 478 +[[image:Screenshot 2025-12-04 at 13.23.18.png||height="309" width="333"]] 477 477 478 478 Figure 4.24. Water level parameter output 479 479 ... ... @@ -485,7 +485,7 @@ 485 485 * Click on the **Setting up rules** icon [[image:Screenshot 2025-12-04 at 13.24.08.png||height="20" width="24"]] 486 486 * In the window that opens (see Fig. 4.25), the** Condition** and **Action** fields need to be filled in for the rule. If highlighting areas based on specific conditions is not required, the **Condition **field can be left empty – in this case, the rendered object is to be displayed using the color specified in the **Action** field. 487 487 488 -[[image:Screenshot 2025-12-04 at 13.24.38.png||height=" 202" width="691"]]490 +[[image:Screenshot 2025-12-04 at 13.24.38.png||height="186" width="634"]] 489 489 490 490 Figure 4.25. Setting the fill depending on the values 491 491 ... ... @@ -509,7 +509,7 @@ 509 509 510 510 To edit the properties of an object, right-click on it and select the **Edit data of the element.** The **Edit data of element **modal window is shown in Fig. 4.26. 511 511 512 -[[image:Screenshot 2025-12-04 at 13.26.04.png]] 514 +[[image:Screenshot 2025-12-04 at 13.26.04.png||height="361" width="873"]] 513 513 514 514 Figure 4.26. Edit the data of the element 515 515 ... ... @@ -522,7 +522,7 @@ 522 522 1. The// Disable context menus, posters, animations// attribute disables animation for such an element if the event is triggered not by changing it, but by changing another attribute included in this object, but if the triggered event relates to this attribute, then animation will work for it. In Fig. 4.27, the dedicated switch is linked to ID 13939, the element TO is linked to the same ID, it is located in the measurements of the object (Activation of the TO). If the **Disable context menus, posters, animations** field is disabled, the TO element will flash at any event related to the object with ID 13939. For the "TO" to flash only at an event that relates to this parameter, the TO element should turn it on. 523 523 1. The //Disable context menus, posters, animations// attribute also disables all context menus that are available to the object, but only measurements remain. In Fig. 3.27, the dedicated switch is linked to ID 13939, the element TO is bound to the same ID, it is located in the measurements of the object (Activation of the TO). If an IM element does not include the// Disable context menus, posters, animations //attribute, then all context menus from the switch are to be available to it. 524 524 525 -[[image:Screenshot 2025-12-04 at 13.27.06.png]] 527 +[[image:Screenshot 2025-12-04 at 13.27.06.png||height="376" width="875"]] 526 526 527 527 Figure 4. 27. Disabling context menus, posters, and animations attribute 528 528 ... ... @@ -529,13 +529,13 @@ 529 529 * **Disabling graphic animation** helps smooth the transition (rotations, offsets, and other geometric changes) of active or dynamic objects from one state to another in the diagram viewing mode. 530 530 * **Enabling element backlight **allows turning on the element highlighting when hovering in the diagram viewer (see Fig. 4.28), which allows the user to determine which diagram objects are active. 531 531 532 -[[image:Screenshot 2025-12-04 at 13.28.03.png]] 534 +[[image:Screenshot 2025-12-04 at 13.28.03.png||height="232" width="328"]] 533 533 534 534 Figure 4.28. Highlighting of an active element of the diagram 535 535 536 536 * **The hidden element** allows adjusting the visibility/invisibility of rendered objects in the diagram viewer. As soon as any object with this setting appears, a button [[image:Screenshot 2025-12-04 at 13.28.37.png||height="26" width="24"]], which hides such an object appears in the viewer in the upper-right corner. Clicking on it displays the diagram object and shows the button like this [[image:Screenshot 2025-12-04 at 13.29.19.png||height="23" width="25"]]. 537 537 538 -[[image:Screenshot 2025-12-04 at 13.29.40.png]] 540 +[[image:Screenshot 2025-12-04 at 13.29.40.png||height="225" width="329"]] 539 539 540 540 Figure 4.29. Highlighting and hiding the active element of the diagram 541 541 ... ... @@ -549,7 +549,7 @@ 549 549 550 550 In the **Measurements (left click)** field, left-click can adjust the number of rows and columns in the table. Fig. 4.30 shows an example of a two-column table. 551 551 552 -[[image:Screenshot 2025-12-04 at 13.30.35.png]] 554 +[[image:Screenshot 2025-12-04 at 13.30.35.png||height="333" width="328"]] 553 553 554 554 Figure 4.30. Changing the view of the measurement table 555 555 ... ... @@ -559,7 +559,7 @@ 559 559 560 560 To quickly manage tags using manual input, a template is provided, which is located in the user category //Manual input.// To use this object, drag it to the diagram canvas (see Fig. 4.31). 561 561 562 -[[image:Screenshot 2025-12-04 at 13.31.44.png]] 564 +[[image:Screenshot 2025-12-04 at 13.31.44.png||height="335" width="661"]] 563 563 564 564 Figure 4.31. Manual input object 565 565 ... ... @@ -714,7 +714,7 @@ 714 714 715 715 Figure 4.49. Displaying a number in exponential form 716 716 717 -== 4.17. Dis playing delimited values ==719 +== 4.17. Displaying delimited values == 718 718 719 719 In the settings [[image:Screenshot 2025-12-04 at 13.50.03.png]] , in diagram view mode, instant tag values can be displayed as delimited values. This setting is enabled by default (see Fig. 4.50). 720 720 ... ... @@ -763,7 +763,7 @@ 763 763 * **Width **is the column width. 764 764 * **Change time **is a system field used to display the time of the metering channel's value change. 765 765 766 -Rows in this table can be moved [[image:Screenshot 2025-12-04 at 14.08.30.png]], deleted [[image:Screenshot 2025-12-04 at 14.09.56.png||height="32" width="33"]], and added [[image:Screenshot 2025-12-04 at 14.10.25.png||height="31" width="89"]]. 768 +Rows in this table can be moved [[image:Screenshot 2025-12-04 at 14.08.30.png]], deleted [[image:Screenshot 2025-12-04 at 14.09.56.png||height="32" width="33"]], and added [[image:Screenshot 2025-12-04 at 14.10.25.png||height="31" width="89"]]. 767 767 768 768 [[image:Screenshot 2025-12-04 at 14.10.47.png]] 769 769 ... ... @@ -825,7 +825,7 @@ 825 825 1. Blocking changes to a layer from the list. 826 826 1. Foreground/background of the layer. 827 827 828 -== 4.21. Active SVG elements ==830 +== 4.21. Active SVG elements == 829 829 830 830 The diagram editor allows importing graphic element templates in SVG format from various sources. Developed animated images from external sources help optimize work in both view and edit modes of the diagram (see Section 4.22.1). They also enable monitoring technological processes with the ability to view moving and rotating objects on the diagram (see Section 4.22.2). 831 831 ... ... @@ -1046,12 +1046,173 @@ 1046 1046 1047 1047 Select the text on the diagram, which is to be a dynamic parameter, and open the window [[image:Screenshot 2025-12-04 at 14.39.54.png||height="28" width="29"]]. 1048 1048 1049 -In the rule, check the box next to the words** Without conditions** (1) (optional) and describe the first action. Mark the**Text** field, select the **Tag** parameter type (2) and write, for example, the ID=502001 (3) number from the database (or select it from the drop-down list (4) see Fig. 5.2), if it is necessary to round the values, enable rounding (5) and specify how many decimal places should be displayed. It is possible to format the text in the actions of the rules (6) (see Fig. 5.3), as well as output the value of the number in exponential form (7). Click **Save,** switch to the diagram [[image:Screenshot 2025-12-04 at 14.40.43.png||height="24" width="31"]]viewing mode and see the result (see Fig. 5.4).1051 +In the rule, check the box next to the words** Without conditions** (1) (optional) and describe the first action. Mark the** Text** field, select the **Tag** parameter type (2) and write, for example, the ID=502001 (3) number from the database (or select it from the drop-down list (4) see Fig. 5.2), if it is necessary to round the values, enable rounding (5) and specify how many decimal places should be displayed. It is possible to format the text in the actions of the rules (6) (see Fig. 5.3), as well as output the value of the number in exponential form (7). Click **Save,** switch to the diagram [[image:Screenshot 2025-12-04 at 14.40.43.png||height="24" width="31"]]viewing mode and see the result (see Fig. 5.4). 1050 1050 1051 1051 [[image:Screenshot 2025-12-04 at 14.41.18.png]] 1052 1052 1053 1053 Figure 5.1. Binding to the text 1054 1054 1055 -To quickly bind to a tag, the **Component visual settings** window can be skipped by using the **Bind an element to a tag or channel** tree [[image:Screenshot 2025-12-04 at 14.41.48.png]] . This automatically fills the tag, see Fig. 5.1.1057 +To quickly bind to a tag, the **Component visual settings** window can be skipped by using the **Bind an element to a tag or channel** tree [[image:Screenshot 2025-12-04 at 14.41.48.png||height="25" width="25"]]. This automatically fills the tag, see Fig. 5.1. 1056 1056 1057 - 1059 +[[image:Screenshot 2025-12-04 at 14.42.21.png]] 1060 + 1061 +Figure 5.2. Choose the parameter drop-down list 1062 + 1063 +[[image:Screenshot 2025-12-04 at 14.42.51.png]] 1064 + 1065 +Figure 5.3. Formatting the text in the rules 1066 + 1067 +[[image:Screenshot 2025-12-04 at 14.43.17.png]] 1068 + 1069 +Figure 5.4. Tag value in the view mode 1070 + 1071 +The tag settings include a field not only for the ID number but also for specifying a code that can be used when binding to the diagram. To do this, in Fig. 5.1, field No. 3, enter the tag code instead of its ID. 1072 + 1073 +In the viewing mode in Fig. 5.4 there is no difference in the display in this case. 1074 + 1075 +**Example No. 2** 1076 + 1077 +An example of binding a real parameter taken from a database, which outputs information on a diagram in the form of a dynamic element that changes color depending on the incoming value and the status of the parameter. 1078 + 1079 +CENTO receives various tag statuses: 1080 + 1081 +[[image:Screenshot 2025-12-04 at 14.44.04.png||height="421" width="343"]] 1082 + 1083 +Figure 5.5. Tag statuses 1084 + 1085 +For example, two statuses can be used: when the telemeasurment TI value is received in real time (i.e., 1 – Normal), and when the telemeasurment TI value is entered manually by the user (i.e., 4 – Manual input). 1086 + 1087 +Real parameter data for binding: 1088 + 1089 +|**ID number**|**Parameter name**|**Values**|**Decryption** 1090 +|10154|Emergency alarm (EA)|0/1|((( 1091 +normal/ 1092 + 1093 +trigerring 1094 +))) 1095 + 1096 +Create a rectangle (with or without fill) and write the text //AC// inside the stroke. 1097 + 1098 +This element changes the background color depending on the incoming value and the status of the parameter, if the condition TI=0 is met, then the color is green, if the condition TI=1 is met, then the color is red, if there is no data, then the color is white (see Fig. 5.6). 1099 + 1100 +[[image:Screenshot 2025-12-04 at 14.45.25.png]] 1101 + 1102 +Figure 5.6. Color changing in a dynamic element 1103 + 1104 +To do this, select the created rectangle with left-clicking and open the bindings window [[image:Screenshot 2025-12-04 at 14.45.55.png||height="25" width="28"]] 1105 + 1106 +Create the following rules: 1107 + 1108 +Rule No. 1 (fill in green with the value of TI = 0): 1109 + 1110 +If the TI value is 0 (normal), then the background is green (see Fig. 5.7). 1111 + 1112 +Rule No. 2 (fill in red with the value of TI = 1): 1113 + 1114 +If the TI value is 1 (signal available, then the background is red (see Fig. 5.8). 1115 + 1116 +Rule No. 3 (fill in white when the T is not equal to 0 and not equal to 1): 1117 + 1118 +If the TI value is not equal to 0 and at the same time the TI value is not equal to 1, then the background is white (see Fig. 5.9). 1119 + 1120 +Rule No. 4 (fill in white if the status is not normal and not with manual input): 1121 + 1122 +If the TI status is not equal to 1 (normal) and at the same time the TI status is not equal to 4 (not manual input), then the background is white (see Fig. 5.10). 1123 + 1124 +[[image:Screenshot 2025-12-04 at 14.46.37.png]] 1125 + 1126 +Figure 5.7. Rule No. 1 1127 + 1128 +[[image:Screenshot 2025-12-04 at 14.46.57.png]] 1129 + 1130 +Figure 5.8. Rule No. 2 1131 + 1132 +[[image:Screenshot 2025-12-04 at 14.47.27.png]] 1133 + 1134 +Figure 5.9. Rule No. 3 1135 + 1136 +[[image:Screenshot 2025-12-04 at 14.47.57.png]] 1137 + 1138 +Figure 5.10. Rule No. 4 1139 + 1140 +== 5.2. Binding devices to the diagram == 1141 + 1142 +There are several device status values: 1143 + 1144 +0 – Disabled, 1145 + 1146 +1 – Normal, 1147 + 1148 +2 – Device has data errors, 1149 + 1150 +3 – Device is unavailable, 1151 + 1152 +4 – Data with manual input available, 1153 + 1154 +7 – Waiting for data, 1155 + 1156 +9 – Status is missing. 1157 + 1158 + The device is bound to the diagram by selecting **Device status** from the menu item. The content of the rules is similar to the example described above with changing the color of an object (in the** Condition** field, select the desired type of parameter, specify the device address, specify the operator and enter a numeric value equal to one or another status, and then specify the **Action **to be applied to the condition being fulfilled, for example, see Fig. 5.11). 1159 + 1160 +[[image:Screenshot 2025-12-04 at 14.49.03.png]] 1161 + 1162 +Figure 5.11. Binding to the device status 1163 + 1164 +Additionally, when using a template with a set of rules, device binding can be performed through the device tree by clicking on [[image:Screenshot 2025-12-04 at 14.49.33.png||height="24" width="25"]]. This automatically fills in the device ID fields shown in Fig. 5.11 streamlining the debugging process without opening the rules window. 1165 + 1166 +== 5.3. Binding parameters to information model objects == 1167 + 1168 +To create an information model, see the "Information model setup manual". 1169 + 1170 +For example, create a square element (to serve as a switch) and describe the rules for it. In this example, the square changes the background color depending on the incoming parameter of the information model object, which refers to the value from the CENTO database. 1171 + 1172 +The sequence of bindings to the parameters of an information model object is like the actions for binding to tags: instead of **Tag value** and **Tag status,** select the** IM attribute** and **IM parameter status**, see Fig. 5.12. 1173 + 1174 +[[image:Screenshot 2025-12-04 at 14.50.40.png]] 1175 + 1176 +Figure 5.12. Binding to the parameter of the information model object 1177 + 1178 +In this example, the address of the parameter is the information model class, and its attribute is selected when opening the drop-down list [[image:Screenshot 2025-12-04 at 14.51.19.png||height="35" width="28"]], see Fig. 5.13. 1179 + 1180 +[[image:Screenshot 2025-12-04 at 14.51.50.png]] 1181 + 1182 +Figure 5.13. Window with IM classes and their attributes 1183 + 1184 +After assembling the shape with the necessary rules for dynamic display, select the entire group and click the left mouse button. In the drop-down window, select **Create active element**, see Fig. 5.14. This function also applies to individual graphic drawings. To bind to the information model, open the appropriate bindings menu [[image:Screenshot 2025-12-04 at 14.52.28.png||height="31" width="31"]]. 1185 + 1186 +[[image:Screenshot 2025-12-04 at 14.52.56.png]] 1187 + 1188 +Figure 5.14. Creating an active element 1189 + 1190 +After creating the active element, the settings shown in Fig. 5.15 become the default. To set properties, right-click on the active element and select **Edit data of element** from the menu. 1191 + 1192 +[[image:Screenshot 2025-12-04 at 14.53.33.png]] 1193 + 1194 +Figure 5.15. Edit the data of elements 1195 + 1196 +After setting up the properties, select the shape and click the button [[image:Screenshot 2025-12-04 at 14.54.04.png||height="27" width="26"]]. Find the necessary element in the tree and select it (see Fig. 5.16). 1197 + 1198 +[[image:Screenshot 2025-12-04 at 14.54.49.png]] 1199 + 1200 +Figure 5.16. Information model element binding 1201 + 1202 +In this way, it is bound to the elements of the information model. When switching from the editor to the diagram viewing mode and right-clicking on the created shape, the **Measurements** context menu appears, showing the complete set of parameters described in the information model, as shown in Fig. 3.3. 1203 + 1204 +Right-clicking displays a table of parameters, which includes all the parameters from measurements, with the option to configure short tag names and decode values, as shown in Fig. 5.17. 1205 + 1206 +[[image:Screenshot 2025-12-04 at 14.55.22.png]] 1207 + 1208 +Figure 5.17. Table of the IM element parameters 1209 + 1210 +This object also has the option to display posters, with their arrangement appearing as shown in Fig. 5.18. 1211 + 1212 +[[image:Screenshot 2025-12-04 at 14.55.48.png]] 1213 + 1214 +Figure 5.18. Installation of customized posters 1215 + 1216 += ABBREVIATIONS = 1217 + 1218 +DB – the database 1219 + 1220 +IM – information model.
- Screenshot 2025-12-04 at 14.53.33.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Lana - Size
-
... ... @@ -1,0 +1,1 @@ 1 +68.6 KB - Content
- Screenshot 2025-12-04 at 14.54.04.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Lana - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.8 KB - Content
- Screenshot 2025-12-04 at 14.54.49.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Lana - Size
-
... ... @@ -1,0 +1,1 @@ 1 +330.4 KB - Content
- Screenshot 2025-12-04 at 14.55.22.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Lana - Size
-
... ... @@ -1,0 +1,1 @@ 1 +83.5 KB - Content
- Screenshot 2025-12-04 at 14.55.48.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Lana - Size
-
... ... @@ -1,0 +1,1 @@ 1 +69.7 KB - Content