Changes for page 8. Control Setup Manual
Last modified by Iaroslav Platonov on 2026/06/09 11:18
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -54,9 +54,9 @@ 54 54 55 55 Figure 2.6. Selecting command for remote control 56 56 57 - =3. SETTING CONTROL=57 +3. SETTING CONTROL 58 58 59 - ==3.1. Setting using WEB interface==59 +3.1. Setting using WEB interface 60 60 61 61 Setting control for tags transmitted via Modbus, OPC DA, or IEC-104 protocols is performed through the **Edit parameter** interface located under Settings > Devices, tags, channels, in the **Tags, channels** tab. In this interface, select the target device in the device tree by checking the box next to it. The device should be configured with one of the supported protocols: Modbus TCP, Modbus RTU over TCP, OPC DA, or IEC-104. To open the tag editing interface, click on the tag identifier or tag name in the general tag list. 62 62 ... ... @@ -71,13 +71,8 @@ 71 71 * Remote control (discrete signal transmission to the device) for IEC-104 protocol: "Remote control is allowed", "Select before operate (SBO)", "Function", "Command duration", "Switch on address", "Switch on value", "Switch off address", "Switch off value", for Modbus TCP protocol: "Remote control is allowed", "Function", "Value length", "Switch on address", "Switch on value", "Switch off value", "Switch off address", "Write by bitmask"; 72 72 * Control (transmission of a positive integer to the device) for Modbus TCP protocol: "Record values", "Function", "Data type in device", "Address", "Byte order", conversion elements: "Physical value (lower limit)", "Physical value (upper limit)", "Value to record (lower limit)", "Value to record (upper limit)", for OPC DA protocol: "Record values", "Device Tag Data Type", conversion elements: "Physical value (lower limit)", "Physical value (upper limit)", "Value to record (lower limit)", "Value to record (upper limit)". 73 73 74 +1. The remote //control// function is available for Modbus TCP Modbus RTU over TCP) protocols (see Fig. 3.1.1) and IEC 104 (see Fig. 3.1.2). 74 74 75 -1) The remote //control// function is available for Modbus TCP Modbus RTU over TCP) protocols (see Fig. 3.1.1) and IEC 104 (see Fig. 3.1.2). 76 - 77 77 The position of the **Remote control is allowed **switch determines whether record commands can be sent to the device at the specified address. 78 78 79 79 The position of the **Select before operate (SBO)** switch defines whether command selection is required prior to executing telecontrol commands. 80 - 81 -In the Remote **control **field, select the appropriate ASDU type for the control command from the drop-down list (see Fig. 3.1.4). 82 - 83 -
- Screenshot 2025-12-17 at 16.38.45.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Lana - Size
-
... ... @@ -1,1 +1,0 @@ 1 -71.4 KB - Content