Changes for page 8. Control Setup Manual
Last modified by Iaroslav Platonov on 2026/06/09 11:18
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,6 @@ 1 -CONTENT 1 += CONTENT = 2 2 3 - ~1. INTRODUCTION3 += 1. INTRODUCTION = 4 4 5 5 CENTO is a multifunctional software platform for data acquisition, processing and display. This manual describes how to configure the CENTO user tool Control. 6 6 ... ... @@ -8,9 +8,9 @@ 8 8 9 9 This manual describes how to configure the Control service, which is used to send control commands to the objects being controlled. 10 10 11 -2. CONTROL USING WEB INTERFACE 11 += 2. CONTROL USING WEB INTERFACE = 12 12 13 -2.1. Control using the device, tags editor 13 +== 2.1. Control using the device, tags editor == 14 14 15 15 A user with the appropriate permissions can control the object using the devices, tags, channels editor. 16 16 ... ... @@ -67,3 +67,12 @@ 67 67 - reading settings as defined in the relevant configuration manuals, 68 68 69 69 - settings for writing: 70 + 71 +* Remote control (discrete signal transmission to the device) for IEC-104 protocol: "Remote control is allowed", "Select before operate (SBO)", "Function", "Command duration", "Switch on address", "Switch on value", "Switch off address", "Switch off value", for Modbus TCP protocol: "Remote control is allowed", "Function", "Value length", "Switch on address", "Switch on value", "Switch off value", "Switch off address", "Write by bitmask"; 72 +* Control (transmission of a positive integer to the device) for Modbus TCP protocol: "Record values", "Function", "Data type in device", "Address", "Byte order", conversion elements: "Physical value (lower limit)", "Physical value (upper limit)", "Value to record (lower limit)", "Value to record (upper limit)", for OPC DA protocol: "Record values", "Device Tag Data Type", conversion elements: "Physical value (lower limit)", "Physical value (upper limit)", "Value to record (lower limit)", "Value to record (upper limit)". 73 + 74 +1. The remote //control// function is available for Modbus TCP Modbus RTU over TCP) protocols (see Fig. 3.1.1) and IEC 104 (see Fig. 3.1.2). 75 + 76 +The position of the **Remote control is allowed **switch determines whether record commands can be sent to the device at the specified address. 77 + 78 +The position of the **Select before operate (SBO)** switch defines whether command selection is required prior to executing telecontrol commands.