Changes for page 3. Metering Channels

Last modified by Iaroslav Platonov on 2026/06/08 09:57

From version 55.1
edited by Lana
on 2025/11/30 19:52
Change comment: Uploaded new attachment "Screenshot 2025-11-30 at 16.52.51.png", version {1}
To version 61.2
edited by Iaroslav Platonov
on 2026/02/04 02:34
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Lana
1 +XWiki.Iaroslav
Content
... ... @@ -1,16 +1,19 @@
1 -== CONTENT ==
1 += CONTENT =
2 2  
3 +{{toc/}}
3 3  
4 -== 1. INTRODUCTION ==
5 +----
5 5  
6 -CENTO is a multifunctional software platform for data collection, processing, and display. This Guide contains a description of setting up metering of electricity, energy resources, as well as other types of metering.
7 += 1. INTRODUCTION =
7 7  
8 -It is assumed that the user, having read the instructions "User manual" and "Setup manual", is already familiar with the main elements of the interface and how to configure CENTO.
9 +(% style="font-size:16px" %)CENTO is a multifunctional software platform for data collection, processing, and display. This Guide contains a description of setting up metering of electricity, energy resources, as well as other types of metering.
9 9  
10 -== 2. ELECTRICITY METERING ==
11 +(% style="font-size:16px" %)It is assumed that the user, having read the instructions "User manual" and "Setup manual", is already familiar with the main elements of the interface and how to configure CENTO.
11 11  
12 -=== 2.1. Device setup ===
13 += 2. ELECTRICITY METERING =
13 13  
15 +== 2.1. Device setup ==
16 +
14 14  CENTO software can work with a variety of metering devices that have the ability to measure and store power and power profiles. The metering function is enabled by adding the metering protocol corresponding to the device on the **Device editing** page (Settings > Devices, tags, channels > Devices), then, similar to other polling protocols, the parameters of communication with the device (RTU address, TCP/UDP port, timeout and number of connection attempts) and scheduled polling parameters (cron of CENTO rules) are specified, to configure electricity metering, the file number is specified in the "File#" field,  which stores power and power profiles.
15 15  
16 16  We will consider the survey of historical data of interval values of accumulated electricity using the example of SATEC devices. For this purpose, the// SATEC (Modbus TCP)// protocol is used (see Fig 2.1).
... ... @@ -83,7 +83,7 @@
83 83  
84 84  Viewing and changing the metering parameters in the memory of the metering device is carried out in accordance with the instructions of the operating manual for this device.
85 85  
86 -=== 2.2. Setting up metering channels ===
89 +== 2.2. Setting up metering channels ==
87 87  
88 88  Electricity meters often do not need to manually add channels to the list of tags, so all the settings are in the metering protocol.  The display of the used accounting channels from the protocol automatically appears on the **Tags, channels** tab, but with a ban on editing actions.
89 89  
... ... @@ -95,11 +95,11 @@
95 95  
96 96  The forms for filling in the fields for setting up electricity metering protocols are different and depend on the type/model of the device, instructions for working with the protocols can be described in different manuals and, if necessary, provided to the User.
97 97  
98 -== 3. ENERGY METERING (COMING) ==
101 += 3. ENERGY METERING (COMING) =
99 99  
100 -=== 3.1. Device Setup (Coming) ===
103 +== 3.1. Device Setup (Coming) ==
101 101  
102 -== 4. OTHER TYPES OF METERING ==
105 += 4. OTHER TYPES OF METERING =
103 103  
104 104  
105 105  In addition to metering electricity and energy resources, the CENTO software supports tracking of operating time, emissions and discharges, as well as product accounting.
... ... @@ -106,7 +106,7 @@
106 106  
107 107  Metering can be implemented not only on the basis of specialized metering devices, but also performed in the CENTO software itself on the basis of tags (real-time data). For example, using information about the state of the equipment (0 - disabled and 1- enabled), the user can set up a metering channel that will calculate the operating time of the equipment. And using the processing functions (see Section 5 of this manual), you can form metering channels (increments) from the current capacity, instantaneous flow or an ever-growing meter.
108 108  
109 -== 5. CALCULATED CHANNELS ==
112 += 5. CALCULATED CHANNELS =
110 110  
111 111  If the device installed at any connection does not have the function of storing interval values of electricity/power in the memory, as well as archived values for other types of metering, CENTO has the function of generating interval values from tags (real-time data). In order to create a metering channel, go to Settings > Devices, tags, channels > Calculation channels (see Fig. 5.1).
112 112  
... ... @@ -114,7 +114,7 @@
114 114  
115 115  Figure 5.1. List of calculated channels
116 116  
117 -=== 5.1. Channel from tag ===
120 +== 5.1. Channel from tag ==
118 118  
119 119  To create a new metering channel from real-time data (tags), click the button [[image:Screenshot 2025-11-30 at 16.28.39.png||height="18" width="92"]]
120 120  
... ... @@ -122,39 +122,39 @@
122 122  
123 123  **editing** page opens. When adjusting an already created metering channel, the page **Channel from tag: editing** will open (see Fig.  5.2).
124 124  
125 -[[image:Screenshot 2025-11-30 at 16.29.45.png]]
128 +[[image:Screenshot 2025-11-30 at 16.29.45.png||height="596" width="724"]]
126 126  
127 127  Figure 5.2. Channel from tag: editing
128 128  
129 129  On the page that opens, specify the name of the channel, its ID (it is written automatically when created, and it does not change for the existing one) and the Code (an optional field), the category of the parameter – electricity/energy resources/technology/emissions/diagnostics/time and the corresponding categories of units of measurement, whether the metering channel has metrological significance, and also fill in the fields:
130 130  
131 -[[image:Screenshot 2025-11-30 at 16.30.29.png]]
134 +[[image:Screenshot 2025-11-30 at 16.30.29.png||height="55" width="219"]]
132 132  
133 133  ID of the tag on the basis of which the calculation channel will be created.
134 134  
135 -[[image:Screenshot 2025-11-30 at 16.30.53.png]]
138 +[[image:Screenshot 2025-11-30 at 16.30.53.png||height="316" width="483"]]
136 136  
137 137  Selection of the device in the object tree from which the specified tag ID is taken.
138 138  
139 -[[image:Screenshot 2025-11-30 at 16.31.25.png]]
142 +[[image:Screenshot 2025-11-30 at 16.31.25.png||height="178" width="483"]]
140 140  
141 141  Function for processing parameter values.
142 142  
143 -[[image:Screenshot 2025-11-30 at 16.31.55.png]]
146 +[[image:Screenshot 2025-11-30 at 16.31.55.png||height="312" width="482"]]
144 144  
145 145  Value aggregation interval.
146 146  
147 -[[image:Screenshot 2025-11-30 at 16.32.28.png]]
150 +[[image:Screenshot 2025-11-30 at 16.32.28.png||height="153" width="478"]]
148 148  
149 149  Processing the calculated channel with formula input.
150 150  
151 -=== 5.2. Calculated channel ===
154 +== 5.2. Calculated channel ==
152 152  
153 153  To create a channel that processes the values of several connections, or interval values, for example, summing up electricity consumption by a group of consumers (total energy consumption) or calculating the balance of consumed energy, click the button on the **Calculated channels** tab (see Fig. 4.1), then click [[image:Screenshot 2025-11-30 at 16.33.58.png||height="22" width="116"]]
154 154  
155 155  When adjusting an already created metering channel, the **Settlement channel: editing** page opens (see Fig. 5.3).
156 156  
157 -[[image:Screenshot 2025-11-30 at 16.34.28.png]]
160 +[[image:Screenshot 2025-11-30 at 16.34.28.png||height="540" width="739"]]
158 158  
159 159  Figure 5.3. Metering channel: editing page
160 160  
... ... @@ -175,25 +175,25 @@
175 175  * rr_imp - R+ readings
176 176  * rr_exp - R- readings
177 177  
178 -=== 5.3.  Calculated channels via Information Model ===
181 +== 5.3.  Calculated channels via Information Model ==
179 179  
180 180  For calculation channels of the same type, it is possible to define custom formulas that operate based on Information Model objects and their attributes. In addition to tags and channels, the Information Model can also supply supplementary data (e.g., reference information). To create a template, click the create template button [[image:Screenshot 2025-11-30 at 16.36.34.png||height="27" width="26"]] as shown in Fig. 5.4.
181 181  
182 -[[image:Screenshot 2025-11-30 at 16.37.01.png]]
185 +[[image:Screenshot 2025-11-30 at 16.37.01.png||height="114" width="566"]]
183 183  
184 184  Fig. 5.4 – Creating a Formula Template
185 185  
186 -[[image:Screenshot 2025-11-30 at 16.37.47.png]]
189 +[[image:Screenshot 2025-11-30 at 16.37.47.png||height="628" width="566"]]
187 187  
188 188  Figure 5.5. Creating custom formula
189 189  
190 190  As shown in Fig. 5.5, the custom formula creation window requires input of the formula name, an optional identifier code, and the formula expression. An example demonstrating the calculation of losses in cable lines is provided in Fig. 5.6.
191 191  
192 -[[image:Screenshot 2025-11-30 at 16.38.43.png]]
195 +[[image:Screenshot 2025-11-30 at 16.38.43.png||height="289" width="566"]]
193 193  
194 194  Figure 5.6. Calculation formula
195 195  
196 -[[image:Screenshot 2025-11-30 at 16.39.09.png]]
199 +[[image:Screenshot 2025-11-30 at 16.39.09.png||height="439" width="719"]]
197 197  
198 198  Figure 5.7. Using calculation formula
199 199  
... ... @@ -209,11 +209,11 @@
209 209  
210 210   The braces **{ }** contain the arguments that need to be entered in the data entry fields as in Fig. 5.7.
211 211  
212 -=== 5.4. Downloading/Uploading calculated channels ===
215 +== 5.4. Downloading/Uploading calculated channels ==
213 213  
214 -The** Downloading/Uploading configuration files** page (Settings > Configuration files) provides functionality for importing and exporting calculation metering channels using Excel files.
217 +The** Downloading/Uploading configuration files** page (Settings > Configuration files) provides functionality for importing and exporting calculation metering channels using Excel files.
215 215  
216 -[[image:Screenshot 2025-11-30 at 16.40.46.png]]
219 +[[image:Screenshot 2025-11-30 at 16.40.46.png||height="527" width="1219"]]
217 217  
218 218  Figure 5.8. Excel file
219 219  
... ... @@ -227,58 +227,70 @@
227 227  |integral|Integral of Values|Integral by tag ID40011100 in a 1-hour time interval
228 228  |first|Indication at the beginning of the interval|first([ti50206_type5], 3600, 0, 0) – calculation of readings based on the ID50206 tag at the beginning of the interval, calculated every hour
229 229  
230 -== 6. RECEIPT OF ACCOUNTING DATA ==
233 += 6. RECEIPT OF ACCOUNTING DATA =
231 231  
232 -The** Analysis of the receipt of data** page is the same for all types of metering. It is described in details in the "User manual"
235 +The** Analysis of the receipt of data** page is the same for all types of metering. It is described in details in the "User manual"
233 233  
234 -=== 6.1. Manual polling ===
237 +== 6.1. Manual polling ==
235 235  
236 236  If it is necessary to re-acquire data from metering devices, a manual poll should be performed. To do this, navigate to the **Receipt of metering data** page (Analysis > Receipt of metering data). This action opens the **Analysis of the receipt of data** interface (see Fig. 6.1)
237 237  
238 -[[image:Screenshot 2025-11-30 at 16.44.01.png]]
241 +[[image:Screenshot 2025-11-30 at 16.44.01.png||height="639" width="1295"]]
239 239  
240 240  Figure 6.1. Analysis of the receipt of data
241 241  
242 242  In the device tree, select the required metering point, find the missing data profiles and click on the button[[image:Screenshot 2025-11-30 at 16.45.10.png||height="25" width="95"]]that instructs the polling service to request an archive from the selected device for the selected interval. After pressing the button, a message about the number of devices to be polled and the time interval will be displayed on the screen. If a message pops up that the operation may take a long time (see Fig. 6.2), it is recommended to reduce the number of devices or the scanning depth (see Fig. 6.3).
243 243  
244 -[[image:Screenshot 2025-11-30 at 16.46.01.png]]
247 +[[image:Screenshot 2025-11-30 at 16.46.01.png||height="180" width="436"]]
245 245  
246 246  Figure 6.2. Message when the number of devices or the polling depth is exceeded.
247 247  
248 248  If the limit is not exceeded, a window pops up:
249 249  
250 -[[image:Screenshot 2025-11-30 at 16.46.40.png]]
253 +[[image:Screenshot 2025-11-30 at 16.46.40.png||height="175" width="439"]]
251 251  
252 252  Figure 6.3. Confirmation of the start of the survey
253 253  
254 254  The **Refresh** button requeries the data from the database for the current view.
255 255  
256 -=== 6.2. Recalculation of calculated channels ===
259 +== 6.2. Recalculation of calculated channels ==
257 257  
258 258  In case of changes in the data used in the calculation channels or changes in the calculation formulas, it is necessary to recalculate the values of the calculated channels. This is performed in the **Analysis of the receipt of data** interface (Analysis > Receipt of metering data). The button [[image:Screenshot 2025-11-30 at 16.47.46.png||height="20" width="70"]] appears if the devices to which the calculated channels are bound are selected in the tree.
259 259  
260 260  If the data used in calculated channels or the calculation formulas themselves are modified, it is necessary to recalculate the values of the calculated channels. This operation is performed through the **Analysis of the receipt of data** interface (Analysis > Receipt of metering data). The recalculation button becomes available when the devices associated with the calculated channels are selected in the tree."
261 261  
262 -[[image:Screenshot 2025-11-30 at 16.48.31.png]]
265 +[[image:Screenshot 2025-11-30 at 16.48.31.png||height="173" width="441"]]
263 263  
264 264  Figure 6.4. Recalculation of channels
265 265  
266 266  At the end of the recalculation process, the information on the **Analysis of metering data** page (Analysis > Metering data) will be updated.
267 267  
268 -== 7. ANALYSIS OF METERING DATA ==
271 += 7. ANALYSIS OF METERING DATA =
269 269  
270 -=== 7.1. Viewing metering data ===
273 +== 7.1. Viewing metering data ==
271 271  
272 -To view historical data on electricity/energy metering, select **Metering data** in the drop-down list of the **Analysis** menu. As a result, the** Analysis of data metering** page opens (see Fig 7.1 – Fig. 7.2).
275 +To view historical data on electricity/energy metering, select **Metering data** in the drop-down list of the **Analysis** menu. As a result, the** Analysis of data metering** page opens (see Fig 7.1 – Fig. 7.2).
273 273  
274 -[[image:Screenshot 2025-11-30 at 16.50.11.png]]
277 +[[image:Screenshot 2025-11-30 at 16.50.11.png||height="533" width="767"]]
275 275  
276 276  Figure 7.1. Charts for electricity channels
277 277  
278 -[[image:Screenshot 2025-11-30 at 16.50.35.png]]
281 +[[image:Screenshot 2025-11-30 at 16.50.35.png||height="533" width="767"]]
279 279  
280 280  Figure 7.2. Charts for energy resources channels
281 281  
282 282  A more detailed description of this interface is described in the "User manual".
283 283  
284 -7.2.
287 +== 7.2. Metering data manual entry ==
288 +
289 +With the appropriate rights, the User can make a manual entry of metering data. To do this, you hover the cursor over the desired cell in the table, perform a left click of the mouse and enter a new value, after which the save value icon appears on the right side of the input field [[image:Screenshot 2025-11-30 at 16.51.39.png]]. Press it or //Enter// on your keyboard, and the value goes to the CENTO database. For devices where only manual data entry is provided, CENTO has developed a procedure for filling the cells between two manual entries. If readings are recorded at 10:00 a.m. and then again at 8:00 p.m., the system automatically fills in the readings for all intermediate intervals. For electricity metering channels, the system additionally calculates and populates the corresponding energy and power values.
290 +
291 +Manual entry of credentials is also available using an .xlsx file.
292 +
293 +The **Download** button allows downloading the selected metering channels to the User's computer in .xlsx format. The downloaded file can be used for manual entry of metering data. To perform manual entry, open the file in the editor. Then enter new data in the fields, mark them **in bold** and save the file [[image:Screenshot 2025-11-30 at 16.52.15.png||height="25" width="66"]] in the CENTO interface. This opens a file upload window with a prompt for use (Fig. 7.3).
294 +
295 +[[image:Screenshot 2025-11-30 at 16.52.51.png||height="323" width="436"]]
296 +
297 +Figure 7.3. Uploading file
298 +
299 +