Changes for page 3. Metering Channels
Last modified by Iaroslav Platonov on 2026/06/08 09:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -197,20 +197,4 @@ 197 197 198 198 Figure 5.7. Using calculation formula 199 199 200 -Fig. 5.7 shows the application of the calculation formula: 201 -3*IM{Object identifier IM}.r_ohm_per_km*pow(agg("mean","{line current}","{Interval}"),2)*0.001, where: 202 - 203 -* **IM{Identifier of the IM object}. r_ohm_per_km **– reference to the value of the attribute with the code **" r_ohm_per_km " "** of the information model object 204 -* **Pow **– exponentiation 205 -* **Agg **is an aggregation function 206 -* **Mean **– average value for the time interval 207 -* **{line current} **– a link to the tag ID 208 -* **{Interval} **– data interval. 209 - 210 - The braces **{ }** contain the arguments that need to be entered in the data entry fields as in Fig. 5.7. 211 - 212 -=== 5.4. Downloading/Uploading calculated channels === 213 - 214 -The** Downloading/Uploading configuration files** page (Settings > Configuration files) provides functionality for importing and exporting calculation metering channels using Excel files. 215 - 216 216
- Screenshot 2025-11-30 at 16.40.46.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Lana - Size
-
... ... @@ -1,1 +1,0 @@ 1 -212.5 KB - Content