Changes for page 3. Metering Channels
Last modified by Iaroslav Platonov on 2026/06/08 09:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -197,4 +197,20 @@ 197 197 198 198 Figure 5.7. Using calculation formula 199 199 200 +Fig. 5.7 shows the application of the calculation formula: 201 +3*IM{Object identifier IM}.r_ohm_per_km*pow(agg("mean","{line current}","{Interval}"),2)*0.001, where: 202 + 203 +* **IM{Identifier of the IM object}. r_ohm_per_km **– reference to the value of the attribute with the code **" r_ohm_per_km " "** of the information model object 204 +* **Pow **– exponentiation 205 +* **Agg **is an aggregation function 206 +* **Mean **– average value for the time interval 207 +* **{line current} **– a link to the tag ID 208 +* **{Interval} **– data interval. 209 + 210 + The braces **{ }** contain the arguments that need to be entered in the data entry fields as in Fig. 5.7. 211 + 212 +=== 5.4. Downloading/Uploading calculated channels === 213 + 214 +The** Downloading/Uploading configuration files** page (Settings > Configuration files) provides functionality for importing and exporting calculation metering channels using Excel files. 215 + 200 200
- Screenshot 2025-11-30 at 16.40.46.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Lana - Size
-
... ... @@ -1,0 +1,1 @@ 1 +212.5 KB - Content