Changes for page 3. Metering Channels
Last modified by Iaroslav Platonov on 2026/06/08 09:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -114,7 +114,7 @@ 114 114 115 115 Figure 5.1. List of calculated channels 116 116 117 -5.1. Channel from tag 117 +=== 5.1. Channel from tag === 118 118 119 119 To create a new metering channel from real-time data (tags), click the button [[image:Screenshot 2025-11-30 at 16.28.39.png||height="18" width="92"]] 120 120 ... ... @@ -142,4 +142,37 @@ 142 142 143 143 [[image:Screenshot 2025-11-30 at 16.31.55.png]] 144 144 145 -Value aggregation interval 145 +Value aggregation interval. 146 + 147 +[[image:Screenshot 2025-11-30 at 16.32.28.png]] 148 + 149 +Processing the calculated channel with formula input. 150 + 151 +=== 5.2. Calculated channel === 152 + 153 +To create a channel that processes the values of several connections, or interval values, for example, summing up electricity consumption by a group of consumers (total energy consumption) or calculating the balance of consumed energy, click the button on the **Calculated channels** tab (see Fig. 4.1), then click [[image:Screenshot 2025-11-30 at 16.33.58.png||height="22" width="116"]] 154 + 155 +When adjusting an already created metering channel, the **Settlement channel: editing** page opens (see Fig. 5.3). 156 + 157 +[[image:Screenshot 2025-11-30 at 16.34.28.png]] 158 + 159 +Figure 5.3. Metering channel: editing page 160 + 161 +On the page that opens, specify the name of the channel, its ID (it is specified automatically when created, but it does not change for the existing one) and the Code (an optional field), the category of the parameter – electricity/energy resources/technology/emissions/diagnostics/time and the corresponding categories of units of measurement, the object and device to which the parameter will be linked. 162 + 163 +In the **Template** field, specify the formula for processing the values of all parameters used in the calculation. The formula can use arithmetic operations, conditions, mathematical functions that are specified in [[image:Screenshot 2025-11-30 at 16.35.23.png||height="30" width="135"]] and the following variables for power channels: 164 + 165 +* ea_imp - energy A+ 166 +* ea_exp - energy A- 167 +* er_imp - energy R+ 168 +* er_exp - energy R- 169 +* pa_imp - power A+ 170 +* pa_exp - power A- 171 +* pr_imp - R+ power 172 +* pr_exp is the power of R- 173 +* ra_imp - A+ readings 174 +* ra_exp - A- readings 175 +* rr_imp - R+ readings 176 +* rr_exp - R- readings 177 + 178 +
- 1764549216682-684.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Lana - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.9 KB - Content
- 1764549295956-131.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Lana - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.0 KB - Content
- Screenshot 2025-11-30 at 16.33.58.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Lana - Size
-
... ... @@ -1,0 +1,1 @@ 1 +6.9 KB - Content
- Screenshot 2025-11-30 at 16.34.28.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Lana - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.1 KB - Content
- Screenshot 2025-11-30 at 16.35.23.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Lana - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.5 KB - Content