16 16  We will consider the survey of historical data of interval values of accumulated electricity using the example of SATEC devices. For this purpose, the// SATEC (Modbus TCP)// protocol is used (see Fig 2.1).
17 17  
18 -[[image:Screenshot 2025-11-27 at 18.53.58.png]]
18 +[[image:Screenshot 2025-11-27 at 18.53.58.png||height="914" width="932"]]
19 19  
20 20  Figure 2.1. Settings of the E/E metering protocol
21 21  
... ... @@ -37,7 +37,7 @@
37 37  
38 38  Serial number of the E/E metering data file in the device's memory (for devices of the Satec type).
39 39  
40 -[[image:Screenshot 2025-11-27 at 18.58.26.png||height="120" width="216"]]
40 +[[image:Screenshot 2025-11-27 at 18.58.26.png||height="80" width="144"]]
41 41  
42 42  Device administrator password.
43 43  
... ... @@ -65,19 +65,19 @@
65 65  
66 66  Enabling/disabling a particular channel.
67 67  
68 -[[image:Screenshot 2025-11-27 at 19.02.20.png||height="96" width="403"]]
68 +[[image:Screenshot 2025-11-27 at 19.02.20.png||height="68" width="285"]]
69 69  
70 70  Serial number of the record (metering channel) in the E/E metering data file in the device's memory (for devices of the Satec type).
71 71  
72 -[[image:Screenshot 2025-11-27 at 19.02.51.png||height="142" width="412"]]
72 +[[image:Screenshot 2025-11-27 at 19.02.51.png||height="100" width="291"]]
73 73  
74 74  When this option is enabled, the specified numbers of energy and power files are not taken into account.
75 75  
76 -[[image:Screenshot 2025-11-27 at 19.03.24.png||height="142" width="138"]]
76 +[[image:Screenshot 2025-11-27 at 19.03.24.png||height="101" width="98"]]
77 77  
78 78  Enabling/disabling reading logs from the device.
79 79  
80 -[[image:Screenshot 2025-11-27 at 19.03.56.png||height="291" width="139"]]
80 +[[image:Screenshot 2025-11-27 at 19.03.56.png||height="205" width="98"]]
81 81  
82 82  Rounding of channels.
83 83  
... ... @@ -101,4 +101,78 @@
101 101  
102 102  == 4. OTHER TYPES OF METERING ==
103 103  
104 +
105 +In addition to metering electricity and energy resources, the CENTO software supports tracking of operating time, emissions and discharges, as well as product accounting.
106 +
107 +Metering can be implemented not only on the basis of specialized metering devices, but also performed in the CENTO software itself on the basis of tags (real-time data). For example, using information about the state of the equipment (0 - disabled and 1- enabled), the user can set up a metering channel that will calculate the operating time of the equipment. And using the processing functions (see Section 5 of this manual), you can form metering channels (increments) from the current capacity, instantaneous flow or an ever-growing meter.
108 +
109 +== 5. CALCULATED CHANNELS ==
110 +
111 +If the device installed at any connection does not have the function of storing interval values of electricity/power in the memory, as well as archived values for other types of metering, CENTO has the function of generating interval values from tags (real-time data). In order to create a metering channel, go to Settings > Devices, tags, channels > Calculation channels (see Fig. 5.1).
112 +
113 +[[image:Screenshot 2025-11-30 at 16.26.53.png]]
114 +
115 +Figure 5.1. List of calculated channels
116 +
117 +=== 5.1. Channel from tag ===
118 +
119 +To create a new metering channel from real-time data (tags), click the button [[image:Screenshot 2025-11-30 at 16.28.39.png||height="18" width="92"]]
120 +
121 +Then the **Channel from tag:**
122 +
123 +**editing** page opens. When adjusting an already created metering channel, the page **Channel from tag: editing** will open (see Fig.  5.2).
124 +
125 +[[image:Screenshot 2025-11-30 at 16.29.45.png]]
126 +
127 +Figure 5.2. Channel from tag: editing
128 +
129 +On the page that opens, specify the name of the channel, its ID (it is written automatically when created, and it does not change for the existing one) and the Code (an optional field), the category of the parameter – electricity/energy resources/technology/emissions/diagnostics/time and the corresponding categories of units of measurement, whether the metering channel has metrological significance, and also fill in the fields:
130 +
131 +[[image:Screenshot 2025-11-30 at 16.30.29.png]]
132 +
133 +ID of the tag on the basis of which the calculation channel will be created.
134 +
135 +[[image:Screenshot 2025-11-30 at 16.30.53.png]]
136 +
137 +Selection of the device in the object tree from which the specified tag ID is taken.
138 +
139 +[[image:Screenshot 2025-11-30 at 16.31.25.png]]
140 +
141 +Function for processing parameter values.
142 +
143 +[[image:Screenshot 2025-11-30 at 16.31.55.png]]
144 +
145 +Value aggregation interval.
146 +
147 +[[image:Screenshot 2025-11-30 at 16.32.28.png]]
148 +
149 +Processing the calculated channel with formula input.
150 +
151 +=== 5.2. Calculated channel ===
152 +
153 +To create a channel that processes the values of several connections, or interval values, for example, summing up electricity consumption by a group of consumers (total energy consumption) or calculating the balance of consumed energy, click the button on the **Calculated channels** tab (see Fig. 4.1), then click [[image:Screenshot 2025-11-30 at 16.33.58.png||height="22" width="116"]]
154 +
155 +When adjusting an already created metering channel, the **Settlement channel: editing** page opens (see Fig. 5.3).
156 +
157 +[[image:Screenshot 2025-11-30 at 16.34.28.png]]
158 +
159 +Figure 5.3. Metering channel: editing page
160 +
161 +On the page that opens, specify the name of the channel, its ID (it is specified automatically when created, but it does not change for the existing one) and the Code (an optional field), the category of the parameter – electricity/energy resources/technology/emissions/diagnostics/time and the corresponding categories of units of measurement, the object and device to which the parameter will be linked.
162 +
163 +In the **Template** field, specify the formula for processing the values of all parameters used in the calculation. The formula can use arithmetic operations, conditions, mathematical functions that are specified in [[image:Screenshot 2025-11-30 at 16.35.23.png||height="30" width="135"]] and the following variables for power channels:
164 +
165 +* ea_imp - energy A+
166 +* ea_exp - energy A-
167 +* er_imp - energy R+
168 +* er_exp - energy R-
169 +* pa_imp - power A+
170 +* pa_exp - power A-
171 +* pr_imp - R+ power
172 +* pr_exp is the power of R-
173 +* ra_imp - A+ readings
174 +* ra_exp - A- readings
175 +* rr_imp - R+ readings
176 +* rr_exp - R- readings
177 +
104 104  
1764548890434-237.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +2.0 KB
Content
1764549216682-684.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +1.9 KB
Content
1764549295956-131.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +2.0 KB
Content
1764549378293-219.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +965 bytes
Content
Screenshot 2025-11-30 at 16.26.53.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +149.8 KB
Content
Screenshot 2025-11-30 at 16.28.39.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +9.5 KB
Content
Screenshot 2025-11-30 at 16.29.45.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +87.4 KB
Content
Screenshot 2025-11-30 at 16.30.29.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +6.1 KB
Content
Screenshot 2025-11-30 at 16.30.53.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +46.3 KB
Content
Screenshot 2025-11-30 at 16.31.25.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +52.5 KB
Content
Screenshot 2025-11-30 at 16.31.55.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +44.9 KB
Content
Screenshot 2025-11-30 at 16.32.28.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +45.0 KB
Content
Screenshot 2025-11-30 at 16.33.58.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +6.9 KB
Content
Screenshot 2025-11-30 at 16.34.28.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +65.1 KB
Content
Screenshot 2025-11-30 at 16.35.23.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +7.5 KB
Content
Screenshot 2025-11-30 at 16.36.34.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lana
Size
... ... @@ -1,0 +1,1 @@
1 +2.4 KB
Content