15 15  
16 16  We will consider the survey of historical data of interval values of accumulated electricity using the example of SATEC devices. For this purpose, the// SATEC (Modbus TCP)// protocol is used (see Fig 2.1).
17 17  
18 -[[image:Screenshot 2025-11-27 at 18.53.58.png]]
18 +[[image:Screenshot 2025-11-27 at 18.53.58.png||height="914" width="932"]]
19 19  
20 20  Figure 2.1. Settings of the E/E metering protocol
21 21  
... ... @@ -37,7 +37,7 @@
37 37  
38 38  Serial number of the E/E metering data file in the device's memory (for devices of the Satec type).
39 39  
40 -[[image:Screenshot 2025-11-27 at 18.58.26.png||height="120" width="216"]]
40 +[[image:Screenshot 2025-11-27 at 18.58.26.png||height="80" width="144"]]
41 41  
42 42  Device administrator password.
43 43  
... ... @@ -65,19 +65,19 @@
65 65  
66 66  Enabling/disabling a particular channel.
67 67  
68 -[[image:Screenshot 2025-11-27 at 19.02.20.png||height="96" width="403"]]
68 +[[image:Screenshot 2025-11-27 at 19.02.20.png||height="68" width="285"]]
69 69  
70 70  Serial number of the record (metering channel) in the E/E metering data file in the device's memory (for devices of the Satec type).
71 71  
72 -[[image:Screenshot 2025-11-27 at 19.02.51.png||height="142" width="412"]]
72 +[[image:Screenshot 2025-11-27 at 19.02.51.png||height="100" width="291"]]
73 73  
74 74  When this option is enabled, the specified numbers of energy and power files are not taken into account.
75 75  
76 -[[image:Screenshot 2025-11-27 at 19.03.24.png||height="142" width="138"]]
76 +[[image:Screenshot 2025-11-27 at 19.03.24.png||height="101" width="98"]]
77 77  
78 78  Enabling/disabling reading logs from the device.
79 79  
80 -[[image:Screenshot 2025-11-27 at 19.03.56.png||height="291" width="139"]]
80 +[[image:Screenshot 2025-11-27 at 19.03.56.png||height="205" width="98"]]
81 81  
82 82  Rounding of channels.
83 83  
... ... @@ -101,4 +101,15 @@
101 101  
102 102  == 4. OTHER TYPES OF METERING ==
103 103  
104 -
104 +
105 +In addition to metering electricity and energy resources, the CENTO software supports tracking of operating time, emissions and discharges, as well as product accounting.
106 +
107 +Metering can be implemented not only on the basis of specialized metering devices, but also performed in the CENTO software itself on the basis of tags (real-time data). For example, using information about the state of the equipment (0 - disabled and 1- enabled), the user can set up a metering channel that will calculate the operating time of the equipment. And using the processing functions (see Section 5 of this manual), you can form metering channels (increments) from the current capacity, instantaneous flow or an ever-growing meter.
108 +
109 +== 5. CALCULATED CHANNELS ==
110 +
111 +If the device installed at any connection does not have the function of storing interval values of electricity/power in the memory, as well as archived values for other types of metering, CENTO has the function of generating interval values from tags (real-time data). In order to create a metering channel, go to Settings > Devices, tags, channels > Calculation channels (see Fig. 5.1).
112 +
113 +[[image:Screenshot 2025-11-30 at 16.26.53.png]]
114 +
115 +Figure 5.1. List of calculated channels