... ... @@ -15,13 +15,13 @@ 15 15 16 16 We will consider the survey of historical data of interval values of accumulated electricity using the example of SATEC devices. For this purpose, the// SATEC (Modbus TCP)// protocol is used (see Fig 2.1). 17 17 18 -[[image:Screenshot 2025-11-27 at 18.53.58.png]] 18 +[[image:Screenshot 2025-11-27 at 18.53.58.png||height="914" width="932"]] 19 19 20 20 Figure 2.1. Settings of the E/E metering protocol 21 21 22 22 Setting up the E/E metering protocol contains the following fields: 23 23 24 -[[image:Screenshot 2025-11-27 at 18.56.14.png||height="63" width="40 2"]]24 +[[image:Screenshot 2025-11-27 at 18.56.14.png||height="63" width="404"]] 25 25 26 26 Selection of the accounting protocol from the drop-down list and its inclusion in the survey. 27 27 ... ... @@ -37,47 +37,47 @@ 37 37 38 38 Serial number of the E/E metering data file in the device's memory (for devices of the Satec type). 39 39 40 -[[image:Screenshot 2025-11-27 at 18.58.26.png||height=" 120" width="216"]]40 +[[image:Screenshot 2025-11-27 at 18.58.26.png||height="80" width="144"]] 41 41 42 42 Device administrator password. 43 43 44 -[[image:Screenshot 2025-11-27 at 18.58.55.png||height="11 5" width="410"]]44 +[[image:Screenshot 2025-11-27 at 18.58.55.png||height="114" width="406"]] 45 45 46 46 Coefficients of conversion of interval values of readings/power (depends on the type of metering device, as well as on the type of connection (direct or with measuring transformers). 47 47 48 -[[image:Screenshot 2025-11-27 at 18.59.34.png]] 48 +[[image:Screenshot 2025-11-27 at 18.59.34.png||height="106" width="410"]] 49 49 50 50 Transformation coefficients of current and voltage transformers, meter coefficient. 51 51 52 -[[image:Screenshot 2025-11-27 at 19.00.09.png]] 52 +[[image:Screenshot 2025-11-27 at 19.00.09.png||height="88" width="217"]] 53 53 54 54 Specifying the TCP connection number for parallel polling of one device (for example, if the device is connected via a Modbus TCP/Modbus RTU converter, then the number of the trunk to which the device is connected is specified). 55 55 56 -[[image:Screenshot 2025-11-27 at 19.00.46.png]] 56 +[[image:Screenshot 2025-11-27 at 19.00.46.png||height="77" width="216"]] 57 57 58 58 Selection of energy/power profile. 59 59 60 -[[image:Screenshot 2025-11-27 at 19.01.19.png]] 60 +[[image:Screenshot 2025-11-27 at 19.01.19.png||height="152" width="406"]] 61 61 62 62 Enabling/disabling the time synchronization of the device on the CENTO side, with the configured period of maximum time correction in seconds, as well as the permissible deviation. 63 63 64 -[[image:Screenshot 2025-11-27 at 19.01.49.png]] 64 +[[image:Screenshot 2025-11-27 at 19.01.49.png||height="240" width="133"]] 65 65 66 66 Enabling/disabling a particular channel. 67 67 68 -[[image:Screenshot 2025-11-27 at 19.02.20.png]] 68 +[[image:Screenshot 2025-11-27 at 19.02.20.png||height="68" width="285"]] 69 69 70 70 Serial number of the record (metering channel) in the E/E metering data file in the device's memory (for devices of the Satec type). 71 71 72 -[[image:Screenshot 2025-11-27 at 19.02.51.png]] 72 +[[image:Screenshot 2025-11-27 at 19.02.51.png||height="100" width="291"]] 73 73 74 74 When this option is enabled, the specified numbers of energy and power files are not taken into account. 75 75 76 -[[image:Screenshot 2025-11-27 at 19.03.24.png]] 76 +[[image:Screenshot 2025-11-27 at 19.03.24.png||height="101" width="98"]] 77 77 78 78 Enabling/disabling reading logs from the device. 79 79 80 -[[image:Screenshot 2025-11-27 at 19.03.56.png]] 80 +[[image:Screenshot 2025-11-27 at 19.03.56.png||height="205" width="98"]] 81 81 82 82 Rounding of channels. 83 83 ... ... @@ -101,4 +101,21 @@ 101 101 102 102 == 4. OTHER TYPES OF METERING == 103 103 104 - 104 + 105 +In addition to metering electricity and energy resources, the CENTO software supports tracking of operating time, emissions and discharges, as well as product accounting. 106 + 107 +Metering can be implemented not only on the basis of specialized metering devices, but also performed in the CENTO software itself on the basis of tags (real-time data). For example, using information about the state of the equipment (0 - disabled and 1- enabled), the user can set up a metering channel that will calculate the operating time of the equipment. And using the processing functions (see Section 5 of this manual), you can form metering channels (increments) from the current capacity, instantaneous flow or an ever-growing meter. 108 + 109 +== 5. CALCULATED CHANNELS == 110 + 111 +If the device installed at any connection does not have the function of storing interval values of electricity/power in the memory, as well as archived values for other types of metering, CENTO has the function of generating interval values from tags (real-time data). In order to create a metering channel, go to Settings > Devices, tags, channels > Calculation channels (see Fig. 5.1). 112 + 113 +[[image:Screenshot 2025-11-30 at 16.26.53.png]] 114 + 115 +Figure 5.1. List of calculated channels 116 + 117 +5.1. Channel from tag 118 + 119 +To create a new metering channel from real-time data (tags), click the button 120 + 121 +Then the **Channel from tag: editing** page opens. When adjusting an already created metering channel, the page **Channel from tag: editing** will opens (see Fig. 5.2).
- 1764548890434-237.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Lana - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.0 KB - Content
- Screenshot 2025-11-30 at 16.26.53.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Lana - Size
-
... ... @@ -1,0 +1,1 @@ 1 +149.8 KB - Content