Changes for page 3. Metering Channels
Last modified by Iaroslav Platonov on 2026/06/08 09:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,4 +1,4 @@ 1 -CONTENT 1 +== CONTENT == 2 2 3 3 4 4 == 1. INTRODUCTION == ... ... @@ -21,51 +21,51 @@ 21 21 22 22 Setting up the E/E metering protocol contains the following fields: 23 23 24 -[[image:Screenshot 2025-11-27 at 18.56.14.png]] 24 +[[image:Screenshot 2025-11-27 at 18.56.14.png||height="63" width="404"]] 25 25 26 26 Selection of the accounting protocol from the drop-down list and its inclusion in the survey. 27 27 28 -[[image:Screenshot 2025-11-27 at 18.56.53.png]] 28 +[[image:Screenshot 2025-11-27 at 18.56.53.png||height="112" width="404"]] 29 29 30 30 Setting up a poll according to the Cron rule (there can be several) with set attempts and timeouts. 31 31 32 -[[image:Screenshot 2025-11-27 at 18.57.26.png]] 32 +[[image:Screenshot 2025-11-27 at 18.57.26.png||height="146" width="408"]] 33 33 34 34 Specifying the network address of the device and the port for the TCP connection. 35 35 36 -[[image:Screenshot 2025-11-27 at 18.57.54.png]] 36 +[[image:Screenshot 2025-11-27 at 18.57.54.png||height="96" width="93"]] 37 37 38 38 Serial number of the E/E metering data file in the device's memory (for devices of the Satec type). 39 39 40 -[[image:Screenshot 2025-11-27 at 18.58.26.png]] 40 +[[image:Screenshot 2025-11-27 at 18.58.26.png||height="120" width="216"]] 41 41 42 42 Device administrator password. 43 43 44 -[[image:Screenshot 2025-11-27 at 18.58.55.png]] 44 +[[image:Screenshot 2025-11-27 at 18.58.55.png||height="114" width="406"]] 45 45 46 46 Coefficients of conversion of interval values of readings/power (depends on the type of metering device, as well as on the type of connection (direct or with measuring transformers). 47 47 48 -[[image:Screenshot 2025-11-27 at 18.59.34.png]] 48 +[[image:Screenshot 2025-11-27 at 18.59.34.png||height="106" width="410"]] 49 49 50 50 Transformation coefficients of current and voltage transformers, meter coefficient. 51 51 52 -[[image:Screenshot 2025-11-27 at 19.00.09.png]] 52 +[[image:Screenshot 2025-11-27 at 19.00.09.png||height="88" width="217"]] 53 53 54 54 Specifying the TCP connection number for parallel polling of one device (for example, if the device is connected via a Modbus TCP/Modbus RTU converter, then the number of the trunk to which the device is connected is specified). 55 55 56 -[[image:Screenshot 2025-11-27 at 19.00.46.png]] 56 +[[image:Screenshot 2025-11-27 at 19.00.46.png||height="77" width="216"]] 57 57 58 58 Selection of energy/power profile. 59 59 60 -[[image:Screenshot 2025-11-27 at 19.01.19.png]] 60 +[[image:Screenshot 2025-11-27 at 19.01.19.png||height="152" width="406"]] 61 61 62 62 Enabling/disabling the time synchronization of the device on the CENTO side, with the configured period of maximum time correction in seconds, as well as the permissible deviation. 63 63 64 -[[image:Screenshot 2025-11-27 at 19.01.49.png]] 64 +[[image:Screenshot 2025-11-27 at 19.01.49.png||height="240" width="133"]] 65 65 66 66 Enabling/disabling a particular channel. 67 67 68 -[[image:Screenshot 2025-11-27 at 19.02.20.png]] 68 +[[image:Screenshot 2025-11-27 at 19.02.20.png||height="94" width="393"]] 69 69 70 70 Serial number of the record (metering channel) in the E/E metering data file in the device's memory (for devices of the Satec type). 71 71