Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -CENTO Manuals.WebHome
1 +CENTO onboarding.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Iaroslav
1 +XWiki.Lana
Content
... ... @@ -1,7 +1,69 @@
1 -{{toc/}}
1 +== **CONTENT** ==
2 2  
3 -= 1. SYSTEM LOGIN =
3 +~1. System login
4 4  
5 +2. Main menu
6 +
7 + 2.1. Diagrams
8 +
9 + 2.2.1. Control
10 +
11 + 2.3. Analysis
12 +
13 + 2.3.1. Real-time data analysis
14 +
15 + 2.3.1.1. Devices, objects
16 +
17 + 2.3.1.2. Statuses
18 +
19 + 2.3.1.3. Time
20 +
21 + 2.3.2. Metering data analysis
22 +
23 + 2.3.3. Receipt of metering data form
24 +
25 + 2.3.4. Device diagnostic
26 +
27 + 2.4. Logs
28 +
29 + 2.4.1. Technology events
30 +
31 + 2.4.2. Camcoders
32 +
33 + 2.4.3. Power quality
34 +
35 + 2.4.4. Waveforms
36 +
37 + 2.4.5. Device events
38 +
39 + 2.4.6. System events
40 +
41 + 2.4.7. User comments log
42 +
43 + 2.4.8. All events log
44 +
45 + 2.4.9. Custom logs
46 +
47 + 2.5. Reports
48 +
49 + 2.5.1. Flexible reports
50 +
51 + 2.5.2. Power quality reports
52 +
53 + 2.5.3. Short circuit currents
54 +
55 + 2.6. Operative journal
56 +
57 + 2.7. Widgets
58 +
59 + 2.8. Sound alerts
60 +
61 + 2.9. Pop-up messages
62 +
63 +----
64 +
65 +== 1. SYSTEM LOGIN ==
66 +
5 5  Users, including the administrator, log in to CENTO through a web interface. The software supports web browsers such as Google Chrome, Microsoft Edge, etc.
6 6  
7 7  To launch the CENTO software web interface, enter the IP address or DNS address of the server on which CENTO software is installed in the address bar of your web browser, for example, [[http:~~/~~/192.168.80.10>>url:http://192.168.80.10/]] or [[https:~~/~~/demo.centosoftware.com/.>>url:https://demo.centosoftware.com/]] When working with the system directly on the server where the CENTO software is installed, enter **http:~/~/127.0.0.1** in the web browser's address bar.
... ... @@ -16,7 +16,7 @@
16 16  
17 17  If the login is successful, the web browser displays the CENTO software web interface panel (see Fig. 2.1).
18 18  
19 -[[image:Screenshot 2025-12-01 at 09.20.57.png]]
81 +[[image:Screenshot 2025-11-12 at 14.11.04.png]]
20 20  
21 21  Figure 1.2. Main panel
22 22  
... ... @@ -38,9 +38,9 @@
38 38  
39 39  Figure 1.4. Access is denied
40 40  
41 -= 2. USER INTERFACE =
103 +== 2. USER INTERFACE ==
42 42  
43 -== 2.1. Main menu ==
105 +=== 2.1. Main menu ===
44 44  
45 45  The upper part of the user interface has a pinned main menu (see Fig. 2.1), which is used to switch between different pages and sections of the CENTO software web interface, as well as a status bar that displays current events and system time. Below is the working area of the CENTO software web interface, which is different for each software section.
46 46  
... ... @@ -106,7 +106,7 @@
106 106  
107 107  Figure 2.3. Drop-down menu
108 108  
109 -== 2.2. Diagrams ==
171 +=== 2.2. Diagrams ===
110 110  
111 111  This main menu item contains a list of diagrams for displaying information being processed by CENTO software. Developing diagrams for displaying information in CENTO software is described in the “Diagrams Development Manual”.  Fig. 2.4. - 2.7. show examples of diagrams.
112 112  
... ... @@ -196,13 +196,13 @@
196 196  
197 197  **Video **is a menu item that, when clicked, opens the view of the video stream from the video surveillance camera (Fig. 2.15). The user can drag the video camera window on the diagram, resize it, open it in a separate window, as well as go to the general log of the object by left-clicking the icon [[image:Screenshot 2025-11-12 at 15.00.15.png]]
198 198  
199 -[[image:image_2025-11-13_10-52-44.png]]
261 +[[image:Screenshot 2025-11-12 at 15.00.44.png]]
200 200  
201 201  Figure 2.15. Viewing video stream
202 202  
203 -**Remote control **is discussed in detail in the next paragraph of this manual.
265 +**Telecontrol **is discussed in detail in the next paragraph of this manual.
204 204  
205 -**Dispatch marks **is a menu item that opens the window for adding dispatch marks. There are four types of marks: info, grounded, ban operation, and admission work. The user with appropriate rights can add, modify, and delete marks. Added marks are displayed as corresponding icons next to the object in the diagram and can be also used to block remote control of the object.
267 +**Dispatch marks **is a menu item that opens the window for adding dispatch marks. There are four types of marks: info, grounded, ban operation, and admission work. The user with appropriate rights can add, modify, and delete marks. Added marks are displayed as corresponding icons next to the object in the diagram and can be also used to block telecontrol of the object.
206 206  
207 207  [[image:Screenshot 2025-11-12 at 15.03.53.png]]
208 208  
... ... @@ -220,17 +220,17 @@
220 220  
221 221  Figure 2.18. Object log
222 222  
223 -=== 2.2.1. Control ===
285 +==== 2.2.1. Control ====
224 224  
225 225  Users with the appropriate permissions can control objects in CENTO. By default, the system grants this permission to users assigned the Dispatcher role.
226 226  
227 227  Control is available in the **Devices, channels, and tags editor** (used during the system configuration stage and described in the “Control Setup Manual”), as well as using the diagrams.
228 228  
229 -On the diagram, when right-clicking a control object, a modal window appears. Depending on the settings and types of control objects, this window includes either a Remote //control //option (typically for objects with the On/Off control type, see Fig. 2.19) or an option named according to the control type (for objects that support numeric control commands, see Fig. 2.20).
291 +On the diagram, when right-clicking a control object, a modal window appears. Depending on the settings and types of control objects, this window includes either a //Telecontrol //option (typically for objects with the On/Off control type, see Fig. 2.19) or an option named according to the control type (for objects that support numeric control commands, see Fig. 2.20).
230 230  
231 231  [[image:Screenshot 2025-11-12 at 18.42.00.png]]
232 232  
233 -Figure 2.19. Remote control
295 +Figure 2.19. Telecontrol
234 234  
235 235  [[image:Screenshot 2025-11-12 at 18.42.35.png]]
236 236  
... ... @@ -258,7 +258,7 @@
258 258  
259 259  Figure 2.24. Window with the field for selecting the named command (2)
260 260  
261 -- a window prompting the selection of a remote control command (for remote control commands, see Fig. 2.25)
323 +- a window prompting the selection of a telecontrol command (for telecontrol commands, see Fig. 2.25)
262 262  
263 263  [[image:Screenshot 2025-11-12 at 18.46.48.png||height="205" width="323"]]
264 264  
... ... @@ -272,9 +272,9 @@
272 272  
273 273  Figure 2.26. Action confirmation
274 274  
275 -For remote control commands, confirmation using the **Execute** button occurs immediately after selecting a command //On// or //Off //(see Fig. 2.27).
337 +For telecontrol commands, confirmation using the **Execute** button occurs immediately after selecting a command //On// or //Off //(see Fig. 2.27).
276 276  
277 -[[image:Screenshot 2025-12-17 at 18.37.08.png]]
339 +[[image:Screenshot 2025-11-12 at 18.48.39.png||height="247" width="316"]]
278 278  
279 279  Figure 2.27. Action confirmation
280 280  
... ... @@ -282,11 +282,11 @@
282 282  
283 283  ----
284 284  
285 -== 2.3. Analysis ==
347 +=== 2.3. Analysis ===
286 286  
287 287  This menu allows displaying information being processed by CENTO software in tabular form, with the ability to systematize and plot charts.
288 288  
289 -=== 2.3.1. Real-time data analysis ===
351 +==== 2.3.1. Real-time data analysis ====
290 290  
291 291  The left part of the **Real-time data analysis **window contains trees for devices, objects, statuses, and time, located on the corresponding tabs (see Fig. 2.28).
292 292  
... ... @@ -294,7 +294,7 @@
294 294  
295 295  Figure 2.28. Real-time data analysis
296 296  
297 -==== 2.3.1.1. Devices, objects. ====
359 +===== 2.3.1.1. Devices, objects. =====
298 298  
299 299  The device tree displays the structure of devices configured in CENTO software and the tags linked to them (see Fig. 2.29). The devices contain all the information sources from which CENTO receives data. The statuses of devices and tags are displayed to the left of the device names in the form of icons.
300 300  
... ... @@ -453,7 +453,7 @@
453 453  
454 454  The **Table** tab displays the same data as the chart but in tabular form (see Fig. 2.37).
455 455  
456 -[[image:Screenshot 2025-11-12 at 19.24.15.png||height="422" width="848"]]
518 +[[image:Screenshot 2025-11-12 at 19.24.15.png||height="611" width="1227"]]
457 457  
458 458  Figure 2.37. Table tab
459 459  
... ... @@ -469,7 +469,7 @@
469 469  
470 470  The height of the lines on the **Real-time data, Table, **and **Time** tabs can be adjusted. It is set by the administrator for all users of the system at the same time. Please refer to the “CENTO Setup Manual” for a description of the settings.
471 471  
472 -==== 2.3.1.2. Statuses ====
534 +===== 2.3.1.2. Statuses =====
473 473  
474 474  The **Statuses** tab (see Fig. 2.38) contains charts of the states of devices and their protocols. The tree structure repeats the structure of the **Devices **tab. The numbers next to the objects indicate How many devices in the branch are polled and have a good status (in green) / How many devices are polled but have a bad status (in red) / How many devices are disabled in the CENTO configuration (in gray).
475 475  
... ... @@ -477,7 +477,7 @@
477 477  
478 478  Figure 2.38. Real-time data analysis in the Statuses tab tree
479 479  
480 -==== 2.3.1.3. Time ====
542 +===== 2.3.1.3. Time =====
481 481  
482 482  The **Time** tab (see Fig. 2.39) is designed to monitor the time on devices capable of transmitting their internal time to CENTO. For such devices to appear in the interface, the time should be collected into a tag named, for example, //Device time//, using a string in the format YYYY-MM-DD HH:MM:SS. On the **Time** tab, the name //Device time// is entered by a user with Administrator rights in the settings window, which is opened by clicking the button [[image:Screenshot 2025-11-12 at 19.47.29.png||height="27" width="26"]].
483 483  
... ... @@ -485,7 +485,7 @@
485 485  
486 486  Fig. 2.39 - Real-time data analysis: Time tab.
487 487  
488 -=== 2.3.2. Metering data analysis ===
550 +==== 2.3.2. Metering data analysis ====
489 489  
490 490  CENTO has tools for working with metering data (electricity, energy resources, operating hours, emissions, etc.). Data is presented to the user in both tabular and graphical formats. Users can choose the chart display style, the period for which data should be shown, aggregate data, and generate reports and data tables in Excel format.
491 491  
... ... @@ -511,7 +511,7 @@
511 511  
512 512  The charts displayed in the right-hand panel can be aggregated using the aggregation drop-down menu (see Fig. 2.42). Several intervals are available, from one hour to one year. After selecting an interval, a window appears to select an aggregation function: sum, average, minimum, or maximum. It is important to note that the aggregation function is applied only to interval values.
513 513  
514 -[[image:Screenshot 2025-11-12 at 20.27.30.png||height="175" width="280"]]
576 +[[image:Screenshot 2025-11-12 at 20.27.30.png]]
515 515  
516 516  Figure 2.42. Aggregation of metering data
517 517  
... ... @@ -547,11 +547,11 @@
547 547  
548 548  Uploading metering data, either in general or for specific devices, depends on the user's configured access rights.
549 549  
550 -=== 2.3.3. Receipt of metering data form ===
612 +==== 2.3.3. Receipt of metering data form ====
551 551  
552 552  When selecting the **Receipt of metering data **item from the **Analysis** menu, the **Analysis of the receipt of data **page opens (see Fig. 2.46).
553 553  
554 -[[image:Screenshot 2025-11-12 at 20.37.28.png||height="605" width="1324"]]
616 +[[image:Screenshot 2025-11-12 at 20.37.28.png]]
555 555  
556 556  Figure 2.46. Analysis of the receipt of data
557 557  
... ... @@ -563,7 +563,7 @@
563 563  
564 564  In the right section of the interface, data receipt profiles for each device are generated based on the received intervals.
565 565  
566 -[[image:Screenshot 2025-11-12 at 20.39.44.png||height="338" width="703"]]
628 +[[image:Screenshot 2025-11-12 at 20.39.44.png]]
567 567  
568 568  Figure 2.47. Pop-up tooltips on the data receipt chart
569 569  
... ... @@ -577,7 +577,7 @@
577 577  
578 578  The **Interrogate **button sends a request to the polling service to retrieve the archive from the selected device for the specified interval. After pressing the button, a message appears on the screen indicating the number of devices being polled and the time interval. If a warning appears stating that the operation may take a long time (see Fig. 2.48), reduce the number of devices or shorten the polling depth.
579 579  
580 -[[image:Screenshot 2025-11-12 at 20.40.26.png||height="146" width="406"]]
642 +[[image:Screenshot 2025-11-12 at 20.40.26.png]]
581 581  
582 582  Figure 2.48. Message displayed when the number of devices or polling depth exceeds the limit
583 583  
... ... @@ -589,11 +589,11 @@
589 589  
590 590  The **Receipt of metering data** interface depends on the user’s configured access rights.
591 591  
592 -=== 2.3.4. **Device diagnostic** ===
654 +==== 2.3.4. **Device diagnostic** ====
593 593  
594 594  If the user has the appropriate rights, device diagnostics is available in the **Analysis** menu by selecting the **Device diagnostic** from the drop-down list (see Fig. 2.49).
595 595  
596 -[[image:Screenshot 2025-11-12 at 20.42.50.png||height="362" width="941"]]
658 +[[image:Screenshot 2025-11-12 at 20.42.50.png]]
597 597  
598 598  Figure 2.49. Device diagnostics interface
599 599  
... ... @@ -605,7 +605,7 @@
605 605  
606 606  When hovering the mouse pointer over a device, a pop-up window appears with all the device protocols and their statuses (see Fig. 2.50)
607 607  
608 -[[image:Screenshot 2025-11-12 at 20.45.11.png||height="162" width="940"]]
670 +[[image:Screenshot 2025-11-12 at 20.45.11.png]]
609 609  
610 610  Figure 2.50. Hovering the mouse pointer over a device
611 611  
... ... @@ -613,27 +613,26 @@
613 613  
614 614  The **Settings** button [[image:Screenshot 2025-11-12 at 20.45.44.png||height="30" width="31"]] opens the window for customizing the diagnostics display (see Fig. 2.51). Here the user can change the width of the screen and the number of columns in which the device bars are placed.
615 615  
616 -[[image:Screenshot 2025-11-12 at 20.46.14.png||height="152" width="231"]]
678 +[[image:Screenshot 2025-11-12 at 20.46.14.png||height="183" width="278"]]
617 617  
618 618  Figure 2.51. Settings menu
619 619  
620 620  The **Filter** button [[image:Screenshot 2025-11-12 at 20.46.51.png||height="29" width="28"]] allows filtering the devices displayed in the scheme by status and type (Fig. 2.52).
621 621  
622 -[[image:Screenshot 2025-11-12 at 20.47.19.png||height="165" width="228"]]
684 +[[image:Screenshot 2025-11-12 at 20.47.19.png||height="203" width="280"]]
623 623  
624 624  Figure 2.52. Filters menu
625 625  
626 626  The **Scale** button [[image:Screenshot 2025-11-12 at 20.47.58.png||height="27" width="28"]] adjusts the scheme to the window size.
627 627  
628 -== 2.4. Logs. ==
690 +2.4. Logs.
629 629  
630 630  This menu item contains a set of logs available depending on the license and access rights. The full list of standard logs includes Technology events, Camcoders, Waveforms, Power quality, Device events, System events, and All Events. Additionally, the user can add custom logs.
631 631  
632 632  Each log displays a list of events in a table indicating the date and time of each event, event description, associated object and device, as well as the event type and severity level (see Fig. 2.53)
633 633  
696 +[[image:Screenshot 2025-11-12 at 20.59.56.png]]
634 634  
635 -[[image:Screenshot 2025-11-20 at 18.36.06.png]]
636 -
637 637  Figure 2.53. Logs
638 638  
639 639  Each event also receives a color code based on its importance level. The colors are configured by users with administrator rights through the event settings interface.
... ... @@ -647,7 +647,7 @@
647 647  
648 648  The **Calendar **[[image:Screenshot 2025-11-12 at 21.01.54.png||height="31" width="259"]] opens a menu to set the period for which data is requested.
649 649  
650 -[[image:Screenshot 2025-11-12 at 21.02.39.png||height="35" width="130"]]
711 +[[image:Screenshot 2025-11-12 at 21.02.39.png||height="47" width="174"]]
651 651  
652 652  - Exporting selected data to MS Excel.
653 653  
... ... @@ -659,7 +659,7 @@
659 659  
660 660  - Buttons to edit and delete custom logs.
661 661  
662 -[[image:Screenshot 2025-11-12 at 21.04.26.png||height="34" width="174"]]
723 +[[image:Screenshot 2025-11-12 at 21.04.26.png||height="37" width="187"]]
663 663  
664 664  - Buttons to control data refresh on the browser page. By default, all logs are static (unlike the Operative events journal described later), loading only the information available at page opening. The drop-down list in the auto-refresh field allows receiving new events at a selected interval.
665 665  
... ... @@ -675,33 +675,30 @@
675 675  
676 676  Figure 2.54. Log display settings
677 677  
678 -=== 2.4.1. Technology events ===
739 +==== 2.4.1. Technology events ====
679 679  
680 680  The **Technology events** log displays events related to technological processes monitored by the system. These include any events specifically configured during system setup - each event is assigned a message text, logic based on tag values or data quality, and additional settings. Examples of such events include changes in the position of switching devices, opening/closing of dampers, and other technological process changes. Setpoints and control commands are also considered technology events.
681 681  
682 -=== 2.4.2. Camcoders ===
743 +==== 2.4.2. Camcoders ====
683 683  
684 -The** Camcoders **is a log containing a list of recordings from video cameras stored on a dedicated video server. All video recordings are bound to objects in the information model, which simplifies the search for specific videos. Recordings can be viewed directly in the CENTO interface or downloaded to the User's computer. The log is available with the appropriate license.
745 +The** Camcoders **is a log containing a list of recordings from video cameras stored on a dedicated video server. All video recordings are bound to objects in the information model, which simplifies the search for specific videos. Recordings can be viewed directly in the CENTO interface or downloaded to the User's computer. The log is available with the appropriate license.
685 685  
686 -=== 2.4.3. Power quality ===
747 +==== 2.4.3. Power quality ====
687 687  
688 688  The **Power Quality** log displays events generated by devices having power quality monitoring function. This type of event notifies users when power quality parameters exceed the thresholds defined in the monitoring device. The log is available with the appropriate license.
689 689  
690 -=== 2.4.4. Waveforms ===
751 +==== 2.4.4. Waveforms ====
691 691  
692 692  The **Waveforms** log is a table that contains a list of waveforms collected from fault event recorders (see Fig. 2.55).
693 693  
694 -[[image:image_2025-11-13_10-57-10.png]]
755 +[[image:Screenshot 2025-11-12 at 22.03.13.png]]
695 695  
696 696  Figure 2.55. Waveforms log
697 697  
698 698  The user can open a waveform directly in the interface (see Fig. 2.56) or download it in COMTRADE format (for further viewing using an alternative waveform viewer) using the **Download** button in the **File** column of the table.
699 699  
761 +[[image:Screenshot 2025-11-12 at 22.04.29.png]]
700 700  
701 -[[image:image_2025-11-13_10-58-05.png]]
702 -
703 -[[image:image_2025-11-13_10-59-02.png]]
704 -
705 705  Figure 2.56. Waveform viewer
706 706  
707 707  More detailed information on waveform viewing can be found in the “Waveform Viewing Manual”.
... ... @@ -708,7 +708,7 @@
708 708  
709 709  This log is available with the appropriate license.
710 710  
711 -=== 2.4.5. Device events ===
769 +==== 2.4.5. Device events ====
712 712  
713 713  The **Device events** log is a list of events provided by the devices (metering devices) in a table with the time of each event, the device bound to the event, as well as the causes and sources of the event (see Fig. 2.57).
714 714  
... ... @@ -716,25 +716,25 @@
716 716  
717 717  Figure 2.57. Device events log
718 718  
719 -=== 2.4.6. System events ===
777 +==== 2.4.6. System events ====
720 720  
721 721  The **System events** log displays information about changes to the CENTO settings. System events include configuration changes (adding, modifying, or deleting parameters, devices, communication protocols, elements of the information model, diagrams, reports), recalculation and manual input of parameters, sending remote control commands, creating, editing, and deleting user accounts, changing access rights, and more. It also covers automatic generation, automatic time synchronization with devices, and server role changes (for redundant configurations).
722 722  
723 723  The **System events** log shows the names of the users responsible for each event.
724 724  
725 -=== 2.4.7. User comments log ===
783 +==== 2.4.7. User comments log ====
726 726  
727 727  The **User comments** log (see Fig. 2.58) contains events generated based on user-entered comments on charts in the **Real-time data analysis** section (see section 2.3.1.1).
728 728  
729 -[[image:Screenshot 2025-11-12 at 22.10.59.png||height="233" width="833"]]
787 +[[image:Screenshot 2025-11-12 at 22.10.59.png]]
730 730  
731 731  Figure 2.58. User comments log
732 732  
733 -=== 2.4.8. All events log ===
791 +==== 2.4.8. All events log ====
734 734  
735 735  The **All events** log aggregates all events received across all logs.
736 736  
737 -=== 2.4.9. Custom logs ===
795 +==== 2.4.9. Custom logs ====
738 738  
739 739  Each User with appropriate rights can create custom logs by selecting the specific events they need.
740 740  
... ... @@ -746,7 +746,7 @@
746 746  
747 747  In addition to filtering, the User can show or hide any log fields and use drag-and-drop using the filter icon [[image:Screenshot 2025-11-12 at 22.12.29.png||height="27" width="25"]] to arrange their order.
748 748  
749 -[[image:Screenshot 2025-11-12 at 22.13.11.png||height="519" width="481"]]
807 +[[image:Screenshot 2025-11-12 at 22.13.11.png]]
750 750  
751 751  Figure 2.59. Events log configuration
752 752  
... ... @@ -754,15 +754,15 @@
754 754  
755 755  Custom logs are visible only to the user who created them.
756 756  
757 -== 2.5. Reports ==
815 +=== 2.5. Reports ===
758 758  
759 759  The **Reports** menu includes **Flexible reports** (included in the CENTO basic version), **Power quality **(license required), **Short circuit** (license required).
760 760  
761 -=== 2.5.1. Flexible reports ===
819 +==== 2.5.1. Flexible reports ====
762 762  
763 763  When selecting **Flexible reports** in the **Reports** drop-down list, the **Flexible reports** page opens (see Fig. 2.60).
764 764  
765 -[[image:Screenshot 2025-11-12 at 22.18.00.png||height="280" width="763"]]
823 +[[image:Screenshot 2025-11-12 at 22.18.00.png]]
766 766  
767 767  Figure 2.60. Flexible reports
768 768  
... ... @@ -770,11 +770,11 @@
770 770  
771 771  The rules for creating, generating, editing, and deleting flexible reports are described in the "Flexible reports. Setup manual".
772 772  
773 -=== 2.5.2. Power quality reports ===
831 +==== 2.5.2. Power quality reports ====
774 774  
775 775  When selecting **Power quality** in the **Reports** drop-down list, the **Power quality reports** page opens (see Fig. 2.61)
776 776  
777 -[[image:Screenshot 2025-11-12 at 22.23.10.png||height="172" width="779"]]
835 +[[image:Screenshot 2025-11-12 at 22.23.10.png]]
778 778  
779 779  Figure 2.61. Power quality reports
780 780  
... ... @@ -786,132 +786,6 @@
786 786  
787 787  The **Statistics collection **tab shows the days on which the device did not send a power quality report
788 788  
789 -=== 2.5.3. Short circuit currents ===
790 -
791 -CENTO allows calculating of short-circuit current. To calculate them, the **Short-circuit current calculation** module and the license are required.
792 -
793 -== 2.6. Operative journal ==
794 -
795 -The **Operative (events) journal** is called by pressing the button [[image:Screenshot 2025-11-12 at 22.27.37.png||height="33" width="34"]] in the CENTO software main menu. It is a window with two areas: on the left there is the area for selecting the types of events to be displayed, on the right there is a list of events with the event date (see Fig. 2.62).
796 -
797 -[[image:Screenshot 2025-11-12 at 22.28.24.png||height="380" width="788"]]
798 -
799 -Figure 2.62. Operative events journal window
800 -
801 -The **Operative events** j**ournal** always overlays the rest of the information on the page.
802 -
803 -Clicking the button [[image:Screenshot 2025-11-12 at 22.29.04.png||height="19" width="21"]] in the upper right corner expands the **Operative events journal** to the full size of the browser window.
804 -
805 -The size of the journal window can be adjusted by dragging the lower right corner while holding down the left mouse button.
806 -
807 -To recognize the type of event and its severity level, each line of the operative journal has an icon characterizing the event in the beginning. These icons can be modified or supplemented during system setup.
808 -
809 -When selecting the **All events** tab in the left area of the **Operative events journal,** the last 100 events formed by the system are displayed on the right side of the journal.
810 -
811 -There are two types of events in CENTO software: single and start/end events. The start/end events allow displaying events in the active state in a separate tab (for example, //ground in a network with an isolated neutral, Opening an emergency exit door//). An event reporting the triggering of this important state is given the status //Active//. An event that signals the end of an important state removes the// Active// status from the first event.
812 -
813 -These two events are start/end events: the second event closes the first one.
814 -
815 -The remaining events (regardless of their importance) are classified as single events.
816 -
817 -The tab [[image:Screenshot 2025-11-12 at 22.31.11.png||height="27" width="71"]] of the **Operative events journal **shows active events on the right side of the window. Both events (active and closing) are displayed in the log of all events independently of one another.
818 -
819 -The events can be communicated to the user (by sound and pop-up alerts) on the diagrams. Depending on the settings, the alerts can last for a specified time or until the user reacts to them. The last ones are called acknowledgeable.
820 -
821 -The number of unacknowledged events is displayed on the operative events journal icon of the main menu: [[image:Screenshot 2025-11-12 at 22.31.47.png||height="29" width="34"]]
822 -
823 -Acknowledged events are displayed in a general list in the log of all events. To see all unacknowledged events separately, go to the **Operative events journal.**
824 -
825 -To acknowledge this event, the user has to click on the icon [[image:Screenshot 2025-11-12 at 22.32.29.png||height="24" width="25"]]in the line of the event.
826 -
827 -The button [[image:Screenshot 2025-11-12 at 22.33.09.png||height="30" width="83"]] on the tab [[image:Screenshot 2025-11-12 at 22.33.31.png||height="33" width="114"]] allows to acknowledge all events with one click (see Fig. 2.63)
828 -
829 -[[image:Screenshot 2025-11-12 at 22.34.09.png||height="400" width="826"]]
830 -
831 -Figure 2.63. Unacknowledged events in the operative events journal
832 -
833 -The icon [[image:Screenshot 2025-11-12 at 22.34.45.png||height="31" width="36"]] in the lower left corner of the **Operative events journal **window opens the journal setting (see Fig. 2.64).
834 -
835 -[[image:Screenshot 2025-11-12 at 22.35.13.png||height="396" width="827"]]
836 -
837 -Figure 2.64. Operative events journal setting
838 -
839 -Thus, the user can hide unnecessary columns, change their order by dragging objects behind the icon [[image:Screenshot 2025-11-12 at 22.35.49.png||height="30" width="28"]], as well as adjust the depth of the tree display in the **Object** column. To apply changes, click **Save**.
840 -
841 -== 2.7. Widgets. ==
842 -
843 -The **Widgets **(operative monitoring widgets) are used to display real-time data to be constantly visible to the operator. The widget's data overlays all other interface elements. The widget is enabled or disabled by left-clicking the icon [[image:Screenshot 2025-11-12 at 22.36.48.png||height="28" width="30"]] in the main menu (see Fig. 2.1).
844 -
845 -To open the widget menu (see Fig. 2.65), right-click the same button.
846 -
847 -[[image:Screenshot 2025-11-12 at 22.37.26.png||height="214" width="227"]]
848 -
849 -Figure 2.65. Widget menu
850 -
851 -This menu allows adding new widgets, as well as hiding or deleting existing ones.
852 -
853 -Click **Add widget **to open the widget customization window (see Fig. 2.66).
854 -
855 -[[image:Screenshot 2025-11-12 at 22.38.11.png||height="350" width="850"]]
856 -
857 -Figure 2.66. Widget menu
858 -
859 -To add parameters to display in the widget, check the boxes next to the required devices in the device tree.
860 -
861 -A list of parameters bound to the selected devices appears in the table to the right of the tree.
862 -
863 - Select the required parameters and click the button [[image:Screenshot 2025-11-12 at 22.38.54.png||height="30" width="30"]](see Fig. 2.67).
864 -
865 -[[image:Screenshot 2025-11-12 at 22.39.26.png||height="351" width="849"]]
866 -
867 -Figure 2.67. Adding parameters to the widget
868 -
869 -To remove parameters from the widget, select the parameters to be removed in the table on the right and click the button [[image:Screenshot 2025-11-12 at 22.40.23.png||height="23" width="23"]].
870 -
871 -By default, a new widget is named //New widget.// To change its name, click the icon [[image:Screenshot 2025-11-12 at 22.40.48.png||height="27" width="27"]] on the top of the widget customization window.
872 -
873 -To customize displaying of the widget name and the units of measure Fig. 2.68), activate or deactivate the **Show widget name** and **Show units of measure** switches in the upper right corner of the widget customization window.
874 -
875 -After saving, the new widget is available for activation.
876 -
877 -[[image:Screenshot 2025-11-12 at 22.41.36.png||height="156" width="357"]]
878 -
879 -Figure 2.68. Displaying data using the widget
880 -
881 -== 2.8. Sound alerts. ==
882 -
883 -CENTO software supports the playback of sound notifications when events occur (the number of sound repetitions, or repetitions until acknowledgement can be set). Sound alerts
884 -
885 -can be turned on and off by clicking the **Sound notifications** icon [[image:Screenshot 2025-11-12 at 22.42.33.png||height="22" width="28"]] in the CENTO software main menu.
886 -
887 -Right-clicking on the icon [[image:Screenshot 2025-11-12 at 22.43.03.png||height="25" width="31"]] opens the sound control window (see Fig. 2.69).
888 -
889 -[[image:Screenshot 2025-11-12 at 22.43.40.png||height="176" width="423"]]
890 -
891 -Figure 2.69. Sound control window
892 -
893 -This window allows turning on and off sounds, adjusting the volume, and checking the sound alerts.
894 -
895 -Sounds can be turned on and off by clicking the On/Off icon [[image:Screenshot 2025-11-12 at 22.44.13.png||height="28" width="27"]].
896 -
897 -The volume is adjusted by the slider.
898 -
899 -The user may experience problems playing sounds due to browser settings. Therefore, it is recommended to check for the appropriate permissions in the used version of the browser if there are no sounds.
900 -
901 -== 2.9. Pop-up messages ==
902 -
903 -The user can learn about an event through pop-up messages. These messages appear in the lower right corner of the CENTO software window on top of other information (see Fig. 2.70).
904 -
905 -[[image:Screenshot 2025-11-12 at 22.45.45.png||height="200" width="339"]]
906 -
907 -Figure 2.70. Pop-up message window
908 -
909 -Pop-up messages can be turned on and off by clicking the icon [[image:Screenshot 2025-11-12 at 22.46.24.png||height="22" width="30"]] in the CENTO software main menu. Pop-up messages disappear from the screen automatically. The user can also close the pop-up window manually by clicking [[image:Screenshot 2025-11-12 at 22.46.53.png||height="24" width="28"]]in the upper right corner of the message.
910 -
911 911  ----
912 912  
913 -= BASIC ABBREVIATIONS =
914 -
915 -IM – information model
916 -
917 -
849 + [[~[MT1~]>>path:#_msoanchor_1]]Are you sure its “did not”? Maybe need a figure to showcase this feature as it is unclear for the user how the statistics can be shown for the days when no data was collected
Screenshot 2025-11-12 at 22.46.24.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Lana
Size
... ... @@ -1,1 +1,0 @@
1 -2.2 KB
Content
Screenshot 2025-11-12 at 22.46.53.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Lana
Size
... ... @@ -1,1 +1,0 @@
1 -2.3 KB
Content
Screenshot 2025-11-12 at 22.48.08.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Lana
Size
... ... @@ -1,1 +1,0 @@
1 -79.9 KB
Content
Screenshot 2025-11-12 at 22.57.37.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Lana
Size
... ... @@ -1,1 +1,0 @@
1 -384.7 KB
Content
Screenshot 2025-11-20 at 18.36.06.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Lana
Size
... ... @@ -1,1 +1,0 @@
1 -1.0 MB
Content
Screenshot 2025-12-01 at 09.20.57.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Lana
Size
... ... @@ -1,1 +1,0 @@
1 -1.3 MB
Content
Screenshot 2025-12-17 at 18.37.08.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Lana
Size
... ... @@ -1,1 +1,0 @@
1 -20.2 KB
Content
image_2025-11-13_10-52-44.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Lana
Size
... ... @@ -1,1 +1,0 @@
1 -216.3 KB
Content
image_2025-11-13_10-57-10.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Lana
Size
... ... @@ -1,1 +1,0 @@
1 -179.0 KB
Content
image_2025-11-13_10-58-05.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Lana
Size
... ... @@ -1,1 +1,0 @@
1 -102.1 KB
Content
image_2025-11-13_10-59-02.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Lana
Size
... ... @@ -1,1 +1,0 @@
1 -110.6 KB
Content