Changes for page 1. User Manual

Last modified by Iaroslav Platonov on 2026/06/08 09:26

From version 211.1
edited by Lana
on 2025/11/13 01:57
Change comment: Uploaded new attachment "Screenshot 2025-11-12 at 22.57.37.png", version {1}
To version 220.1
edited by Lana
on 2025/11/20 21:35
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,67 +1,9 @@
1 -== **CONTENT** ==
1 +----
2 2  
3 -~1. System login
3 +== CONTENT ==
4 4  
5 -2. Main menu
5 +{{toc/}}
6 6  
7 - 2.1. Diagrams
8 -
9 - 2.2.1. Control
10 -
11 - 2.3. Analysis
12 -
13 - 2.3.1. Real-time data analysis
14 -
15 - 2.3.1.1. Devices, objects
16 -
17 - 2.3.1.2. Statuses
18 -
19 - 2.3.1.3. Time
20 -
21 - 2.3.2. Metering data analysis
22 -
23 - 2.3.3. Receipt of metering data form
24 -
25 - 2.3.4. Device diagnostic
26 -
27 - 2.4. Logs
28 -
29 - 2.4.1. Technology events
30 -
31 - 2.4.2. Camcoders
32 -
33 - 2.4.3. Power quality
34 -
35 - 2.4.4. Waveforms
36 -
37 - 2.4.5. Device events
38 -
39 - 2.4.6. System events
40 -
41 - 2.4.7. User comments log
42 -
43 - 2.4.8. All events log
44 -
45 - 2.4.9. Custom logs
46 -
47 - 2.5. Reports
48 -
49 - 2.5.1. Flexible reports
50 -
51 - 2.5.2. Power quality reports
52 -
53 - 2.5.3. Short circuit currents
54 -
55 - 2.6. Operative journal
56 -
57 - 2.7. Widgets
58 -
59 - 2.8. Sound alerts
60 -
61 - 2.9. Pop-up messages
62 -
63 -----
64 -
65 65  == 1. SYSTEM LOGIN ==
66 66  
67 67  Users, including the administrator, log in to CENTO through a web interface. The software supports web browsers such as Google Chrome, Microsoft Edge, etc.
... ... @@ -742,7 +742,7 @@
742 742  
743 743  ==== 2.4.2. Camcoders ====
744 744  
745 -The** Camcoders **is a log containing a list of recordings from video cameras stored on a dedicated video server. All video recordings are bound to objects in the information model, which simplifies the search for specific videos. Recordings can be viewed directly in the CENTO interface or downloaded to the User's computer. The log is available with the appropriate license.
687 +The** Camcoders **is a log containing a list of recordings from video cameras stored on a dedicated video server. All video recordings are bound to objects in the information model, which simplifies the search for specific videos. Recordings can be viewed directly in the CENTO interface or downloaded to the User's computer. The log is available with the appropriate license.
746 746  
747 747  ==== 2.4.3. Power quality ====
748 748  
... ... @@ -760,6 +760,8 @@
760 760  
761 761  [[image:Screenshot 2025-11-12 at 22.04.29.png||height="414" width="1219"]]
762 762  
705 +[[image:Screenshot 2025-11-12 at 22.57.37.png]]
706 +
763 763  Figure 2.56. Waveform viewer
764 764  
765 765  More detailed information on waveform viewing can be found in the “Waveform Viewing Manual”.
... ... @@ -866,7 +866,7 @@
866 866  
867 867  When selecting the **All events** tab in the left area of the **Operative events journal,** the last 100 events formed by the system are displayed on the right side of the journal.
868 868  
869 -There are two types of events in CENTO software: single and with return. The with return events allow displaying events in the active state in a separate tab (for example, //ground in a network with an isolated neutral, Opening an emergency exit door//). An event reporting the triggering of this important state is given the status //Active//. An event that signals the end of an important state removes the// Active// status from the first event.
813 +There are two types of events in CENTO software: single and with return. The with return events allow displaying events in the active state in a separate tab (for example, //ground in a network with an isolated neutral, Opening an emergency exit door//). An event reporting the triggering of this important state is given the status //Active//. An event that signals the end of an important state removes the// Active// status from the first event.
870 870  
871 871  These two events are with return: the second event closes the first one.
872 872  
... ... @@ -940,9 +940,9 @@
940 940  
941 941  CENTO software supports the playback of sound notifications when events occur (the number of sound repetitions, or repetitions until acknowledgement can be set). Sound alerts
942 942  
943 -can be turned on and off by clicking the **Sound notifications** icon [[image:Screenshot 2025-11-12 at 22.42.33.png||height="22" width="28"]] in the CENTO software main menu. ​​​​​​​
887 +can be turned on and off by clicking the **Sound notifications** icon [[image:Screenshot 2025-11-12 at 22.42.33.png||height="22" width="28"]] in the CENTO software main menu.
944 944  
945 -Right-clicking on the icon [[image:Screenshot 2025-11-12 at 22.43.03.png||height="25" width="31"]] opens the sound control window (see Fig. 2.69).​​​​​​​
889 +Right-clicking on the icon [[image:Screenshot 2025-11-12 at 22.43.03.png||height="25" width="31"]] opens the sound control window (see Fig. 2.69).
946 946  
947 947  [[image:Screenshot 2025-11-12 at 22.43.40.png||height="176" width="423"]]
948 948  
... ... @@ -964,7 +964,7 @@
964 964  
965 965  Figure 2.70. Pop-up message window
966 966  
967 -Pop-up messages can be turned on and off by clicking the icon [[image:Screenshot 2025-11-12 at 22.46.24.png||height="22" width="30"]] in the CENTO software main menu. Pop-up messages disappear from the screen automatically. The user can also close the pop-up window manually by clicking [[image:Screenshot 2025-11-12 at 22.46.53.png||height="24" width="28"]]in the upper right corner of the message.​​​​​​​
911 +Pop-up messages can be turned on and off by clicking the icon [[image:Screenshot 2025-11-12 at 22.46.24.png||height="22" width="30"]] in the CENTO software main menu. Pop-up messages disappear from the screen automatically. The user can also close the pop-up window manually by clicking [[image:Screenshot 2025-11-12 at 22.46.53.png||height="24" width="28"]]in the upper right corner of the message.
968 968  
969 969  ----
970 970