Changes for page 1. User Manual
Last modified by Iaroslav Platonov on 2026/06/08 09:26
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -324,45 +324,38 @@ 324 324 325 325 Table 2.1. Device statuses 326 326 327 -|Status Nr|((( 327 +(% style="width:705px" %) 328 +|(% style="width:124px" %)Status Nr|(% style="width:118px" %)((( 328 328 Device 329 329 330 330 status 331 -)))|Decoding 332 -|0|[[image:1763003034315-413.png]]|Disabled (device polling is disabled in CENTO software) 333 -|1|[[image:1763003034316-416.png]]|Normal (device is online, tags are polled without errors) 334 -|2|((( 335 - 336 - 332 +)))|(% style="width:459px" %)Decoding 333 +|(% style="width:124px" %)0|(% style="width:118px" %)[[image:1763003034315-413.png]]|(% style="width:459px" %)Disabled (device polling is disabled in CENTO software) 334 +|(% style="width:124px" %)1|(% style="width:118px" %)[[image:1763003034316-416.png]]|(% style="width:459px" %)Normal (device is online, tags are polled without errors) 335 +|(% style="width:124px" %)2|(% style="width:118px" %)((( 337 337 [[image:1763003034316-762.png]] 338 -)))|((( 337 +)))|(% style="width:459px" %)((( 339 339 Data in the device with errors (some tags come with errors or are 340 340 341 341 not polled) 342 342 ))) 343 -|3|((( 344 - 345 - 342 +|(% style="width:124px" %)3|(% style="width:118px" %)((( 346 346 [[image:1763003034316-558.png]] 347 -)))|((( 344 +)))|(% style="width:459px" %)((( 348 348 Device unavailable (device polling is enabled, but the device is 349 349 350 350 not responding) 351 351 ))) 352 -|4|((( 353 - 354 - 349 +|(% style="width:124px" %)4|(% style="width:118px" %)((( 355 355 [[image:1763003034317-657.png]] 356 -)))|((( 351 +)))|(% style="width:459px" %)((( 357 357 Manual input data are present in the tags or channels for the 358 358 359 359 device 360 360 ))) 361 -|9|((( 362 - 363 - 356 +|(% style="width:124px" %)9|(% style="width:118px" %)((( 364 364 [[image:1763003034317-972.png]] 365 -)))|((( 358 +)))|(% style="width:459px" %)((( 366 366 Status is not available (status has not been received yet or is 367 367 368 368 missing) ... ... @@ -370,6 +370,7 @@ 370 370 371 371 Table 2.2. Tag statuses 372 372 366 +(% style="width:704px" %) 373 373 |((( 374 374 Status 375 375 ... ... @@ -378,30 +378,28 @@ 378 378 Tag 379 379 380 380 status 381 -)))|Decoding 382 -|0|[[image:1763003092665-496.png]]|Disabled (tag polling is disabled in CENTO software) 383 -|1|[[image:1763003092666-152.png]]|Normal (tag is polled without errors) 384 -|2|[[image:1763003092666-164.png]]|Processing error (tag value received with errors) 385 -|3|[[image:1763003092666-447.png]]|Receiving error (tag value do not received) 386 -|4|[[image:1763003092666-800.png]]|Manual input of tag value 387 -|5|[[image:1763003092667-675.png]]|Manual input in the arguments of the pre-calculated tag 388 -|6|[[image:1763003092667-237.png]]|Disabled device or protocol 375 +)))|(% style="width:456px" %)Decoding 376 +|0|[[image:1763003092665-496.png]]|(% style="width:456px" %)Disabled (tag polling is disabled in CENTO software) 377 +|1|[[image:1763003092666-152.png]]|(% style="width:456px" %)Normal (tag is polled without errors) 378 +|2|[[image:1763003092666-164.png]]|(% style="width:456px" %)Processing error (tag value received with errors) 379 +|3|[[image:1763003092666-447.png]]|(% style="width:456px" %)Receiving error (tag value do not received) 380 +|4|[[image:1763003092666-800.png]]|(% style="width:456px" %)Manual input of tag value 381 +|5|[[image:1763003092667-675.png]]|(% style="width:456px" %)Manual input in the arguments of the pre-calculated tag 382 +|6|[[image:1763003092667-237.png]]|(% style="width:456px" %)Disabled device or protocol 389 389 |8|((( 390 - 391 - 392 392 [[image:1763003092667-501.png]] 393 -)))|((( 385 +)))|(% style="width:456px" %)((( 394 394 Bad tag quality (tag received from device with bad quality or 395 395 396 -processing with bad quality tag) 388 +processing with a bad quality tag) 397 397 ))) 398 -|9|[[image:1763003092667-969.png]]|Status is unknown (status has not been received yet or is missing) 390 +|9|[[image:1763003092667-969.png]]|(% style="width:456px" %)Status is unknown (status has not been received yet or is missing) 399 399 400 400 The right part of the screen (for both the Device and Object trees) has a window with three tabs: **Real-time data, Chart, Table.** The **Real-time data** tab is enabled by default. It contains a table of tags selected in the //Device tree,// or the //Object tree;// or a table of protocol and device statuses if the **Statuses **tab is opened. 401 401 402 402 The **Tag** table (see Fig. 2.31) contains the following information: 403 403 404 -[[image:Screenshot 2025-11-12 at 19.06.00.png]] 396 +[[image:Screenshot 2025-11-12 at 19.06.00.png||height="162" width="1228"]] 405 405 406 406 Figure 2.31. Tag table in the Real-time data analysis 407 407 ... ... @@ -439,7 +439,7 @@ 439 439 440 440 The button [[image:Screenshot 2025-11-12 at 19.14.57.png||height="28" width="28"]] opens the **Chart settings** menu (see Fig. 2.34). This menu allows selecting the chart type (columns or stepline) and its location (on one axis or on different axes). The user's choice of chart settings is remembered by the browser and the next time the page is visited, the chart opens with the same settings. 441 441 442 -[[image:Screenshot 2025-11-12 at 19.18.15.png]] 434 +[[image:Screenshot 2025-11-12 at 19.18.15.png||height="209" width="314"]] 443 443 444 444 Figure 2.34. Chart settings menu 445 445 ... ... @@ -477,10 +477,12 @@ 477 477 478 478 At the bottom of the **Chart** and **Table** tabs, there are the navigation and chart display buttons. 479 479 480 -By default, the** Chart** displays 5 charts. Using the number of charts field [[image:Screenshot 2025-11-12 at 19.25.24.png||height="22" width="75"]] allows displaying a different number of charts, but no more than 15.472 +By default, the** Chart** displays 5 charts. Using the number of charts field [[image:Screenshot 2025-11-12 at 19.25.24.png||height="22" width="75"]] allows displaying a different number of charts, but no more than 15. 481 481 482 482 The **Back** and **Forward** buttons [[image:Screenshot 2025-11-12 at 19.26.03.png||height="36" width="67"]] allow moving the selected chart interval backwards and forwards. 483 483 484 -If the User selected more charts than fits the screen, navigation is activated 476 +If the User selected more charts than fits the screen, navigation is activated [[image:Screenshot 2025-11-12 at 19.26.58.png||height="29" width="159"]]. This allows the user to switch between the charts. The **Table** provides a similar function [[image:Screenshot 2025-11-12 at 19.27.50.png||height="27" width="80"]]. 485 485 478 +The height of the lines on the **Real-time data, Table, **and **Time** tabs can be adjusted. It is set by the administrator for all users of the system at the same time. Please refer to the “CENTO Setup Manual” for a description of the settings. 479 + 486 486